Evaluation of Patients’ Received Doses in Chest CT Scan Protocols for COVID-19 Diagnosis

Purpose: This study aims to investigate and compare the doses received by Corona Virus Disease (Covid-19) patients on Computed Tomography (CT) scans by changing the scan parameters to diagnose the disease and evaluate its course and effects. Materials and Methods: The total number of patients wa...

Full description

Saved in:
Bibliographic Details
Main Authors: Sadegh Shurche, Tinoosh Almasi, Maryam Tima, Nima Rostampour
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2025-01-01
Series:Frontiers in Biomedical Technologies
Subjects:
Online Access:https://fbt.tums.ac.ir/index.php/fbt/article/view/654
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823863956469448704
author Sadegh Shurche
Tinoosh Almasi
Maryam Tima
Nima Rostampour
author_facet Sadegh Shurche
Tinoosh Almasi
Maryam Tima
Nima Rostampour
author_sort Sadegh Shurche
collection DOAJ
description Purpose: This study aims to investigate and compare the doses received by Corona Virus Disease (Covid-19) patients on Computed Tomography (CT) scans by changing the scan parameters to diagnose the disease and evaluate its course and effects. Materials and Methods: The total number of patients was 8290, with 4070 requesting a CT scan of the lungs. In 3512 cases, the purpose of the examination was to verify Covid-19. The remaining 558 scans were for other diseases. Two CT protocols were used for lung imaging: A low-dose protocol (kV=120 kVp and mAs=80ms) to screen for Covid-19 and a Smart protocol (kV=120 kVp and mAs = Smart) for other diseases. Each image was assigned a score from 1 to 5. The score reflects the quality of the image and Covid-19-related features such as Ground Glass Opacities (GGO), crazy paving, consolidation, Nodular Infiltrates (NI), Broncho Vascular Thickening (BVT), and Pleural Effusion (PE). Results: In the low-dose protocol, the effective dose received by patients varied between 1.98 and 2.66 ± 0.1 milli Sievert (mSv) according to the different Dose-Length Product (DLP) values. The effective dose varies between 2.7 and 8.44 mSv for the Smart protocol. The maximum Size-Specific Dose Estimate (SSDE) was 11.97 ± 0.2 and 21.58 ± 0.9 milli Gray (mGy) for each protocol, respectively. The maximum carcinogenicity was 1.09 × 10−4 and 3.05 × 10−4, respectively. Radiologists gave an overall acceptance rate of 4.9 ± 0.1 and 4.8 ± 0.2 out of a possible 5-point for images with low-dose and smart protocols, respectively. Conclusion: Decreasing the value of milli Ampere-seconds (mAs) decreases the effective dose, the size-specific dose estimate, and the carcinogenicity of radiation in patients requesting scans of the lungs CT. Images lose quality but are still good enough to determine the progression and impact of Covid-19.
format Article
id doaj-art-d8800246b6154aa9b769c3db63f34821
institution Kabale University
issn 2345-5837
language English
publishDate 2025-01-01
publisher Tehran University of Medical Sciences
record_format Article
series Frontiers in Biomedical Technologies
spelling doaj-art-d8800246b6154aa9b769c3db63f348212025-02-09T08:56:01ZengTehran University of Medical SciencesFrontiers in Biomedical Technologies2345-58372025-01-0112110.18502/fbt.v12i1.17730Evaluation of Patients’ Received Doses in Chest CT Scan Protocols for COVID-19 DiagnosisSadegh Shurche0Tinoosh Almasi1Maryam Tima2Nima Rostampour3Department of Medical Physics, Faculty of Medicine, Tarbiat Modares University, Tehran, IranDepartment of Medical Physics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, IranMedical Imaging Department, Chamran Hospital, Kermanshah University of Medical Sciences, Kermanshah, IranDepartment of Medical Physics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran Purpose: This study aims to investigate and compare the doses received by Corona Virus Disease (Covid-19) patients on Computed Tomography (CT) scans by changing the scan parameters to diagnose the disease and evaluate its course and effects. Materials and Methods: The total number of patients was 8290, with 4070 requesting a CT scan of the lungs. In 3512 cases, the purpose of the examination was to verify Covid-19. The remaining 558 scans were for other diseases. Two CT protocols were used for lung imaging: A low-dose protocol (kV=120 kVp and mAs=80ms) to screen for Covid-19 and a Smart protocol (kV=120 kVp and mAs = Smart) for other diseases. Each image was assigned a score from 1 to 5. The score reflects the quality of the image and Covid-19-related features such as Ground Glass Opacities (GGO), crazy paving, consolidation, Nodular Infiltrates (NI), Broncho Vascular Thickening (BVT), and Pleural Effusion (PE). Results: In the low-dose protocol, the effective dose received by patients varied between 1.98 and 2.66 ± 0.1 milli Sievert (mSv) according to the different Dose-Length Product (DLP) values. The effective dose varies between 2.7 and 8.44 mSv for the Smart protocol. The maximum Size-Specific Dose Estimate (SSDE) was 11.97 ± 0.2 and 21.58 ± 0.9 milli Gray (mGy) for each protocol, respectively. The maximum carcinogenicity was 1.09 × 10−4 and 3.05 × 10−4, respectively. Radiologists gave an overall acceptance rate of 4.9 ± 0.1 and 4.8 ± 0.2 out of a possible 5-point for images with low-dose and smart protocols, respectively. Conclusion: Decreasing the value of milli Ampere-seconds (mAs) decreases the effective dose, the size-specific dose estimate, and the carcinogenicity of radiation in patients requesting scans of the lungs CT. Images lose quality but are still good enough to determine the progression and impact of Covid-19. https://fbt.tums.ac.ir/index.php/fbt/article/view/654Computed TomographyCorona Virus Disease -19Low-Dose ProtocolSmart Scan
spellingShingle Sadegh Shurche
Tinoosh Almasi
Maryam Tima
Nima Rostampour
Evaluation of Patients’ Received Doses in Chest CT Scan Protocols for COVID-19 Diagnosis
Frontiers in Biomedical Technologies
Computed Tomography
Corona Virus Disease -19
Low-Dose Protocol
Smart Scan
title Evaluation of Patients’ Received Doses in Chest CT Scan Protocols for COVID-19 Diagnosis
title_full Evaluation of Patients’ Received Doses in Chest CT Scan Protocols for COVID-19 Diagnosis
title_fullStr Evaluation of Patients’ Received Doses in Chest CT Scan Protocols for COVID-19 Diagnosis
title_full_unstemmed Evaluation of Patients’ Received Doses in Chest CT Scan Protocols for COVID-19 Diagnosis
title_short Evaluation of Patients’ Received Doses in Chest CT Scan Protocols for COVID-19 Diagnosis
title_sort evaluation of patients received doses in chest ct scan protocols for covid 19 diagnosis
topic Computed Tomography
Corona Virus Disease -19
Low-Dose Protocol
Smart Scan
url https://fbt.tums.ac.ir/index.php/fbt/article/view/654
work_keys_str_mv AT sadeghshurche evaluationofpatientsreceiveddosesinchestctscanprotocolsforcovid19diagnosis
AT tinooshalmasi evaluationofpatientsreceiveddosesinchestctscanprotocolsforcovid19diagnosis
AT maryamtima evaluationofpatientsreceiveddosesinchestctscanprotocolsforcovid19diagnosis
AT nimarostampour evaluationofpatientsreceiveddosesinchestctscanprotocolsforcovid19diagnosis