Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal Anesthesia

Background. Enlarged uterus can compress the inferior vena cava and cause hypotension when lying supine. Previous studies have shown a positive association between the abdominal circumference and size of the uterus. Therefore, the aim of this study was to evaluate the relationship between abdominal...

Full description

Saved in:
Bibliographic Details
Main Authors: Pattaraleeya Thomard, Sunthiti Morakul, Nichawan Wirachpisit, Wichai Ittichaikulthol, Chawika Pisitsak
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Anesthesiology Research and Practice
Online Access:http://dx.doi.org/10.1155/2020/6547927
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832550521321291776
author Pattaraleeya Thomard
Sunthiti Morakul
Nichawan Wirachpisit
Wichai Ittichaikulthol
Chawika Pisitsak
author_facet Pattaraleeya Thomard
Sunthiti Morakul
Nichawan Wirachpisit
Wichai Ittichaikulthol
Chawika Pisitsak
author_sort Pattaraleeya Thomard
collection DOAJ
description Background. Enlarged uterus can compress the inferior vena cava and cause hypotension when lying supine. Previous studies have shown a positive association between the abdominal circumference and size of the uterus. Therefore, the aim of this study was to evaluate the relationship between abdominal circumference and incidence of hypotension during cesarean section under spinal anesthesia. Methods. The study cohort comprised women undergoing cesarean section under spinal anesthesia. Patients were divided into two groups according to the median abdominal circumference (<101 cm and ≥101 cm). Hypotension was defined as a systolic blood pressure of <90 mmHg or mean arterial pressure of <65 mmHg. The primary outcome of this study was the relationship between the incidence of hypotension and the abdominal circumference after spinal anesthesia in term pregnant women. Results. The study cohort comprised 100 women. The incidence of hypotension did not differ between the groups (71.42% in the smaller vs. 78.43% in the larger abdominal circumference group, p=0.419). However, the decrease in mean arterial pressure and its percentage decrease from baseline were greater in the larger than in the smaller abdominal circumference group (change in mean arterial pressure: 28.33 mmHg (18.66–33.67) in the smaller vs. 36.67 mmHg (23.34–43.34) in the larger abdominal circumference group, p=0.004; percentage decrease: 31.41% (22.74–39.22) in the smaller vs. 38.47% (28.00–44.81) in the larger abdominal circumference group, p=0.022). Conclusions. Large abdominal circumference in pregnancy is associated with greater decreases in mean arterial pressure from baseline. However, the incidence of hypotension defined by standard criteria did not differ between larger and smaller abdominal circumference groups.
format Article
id doaj-art-d7c764646f2343fd9c64699f7cf81871
institution Kabale University
issn 1687-6962
1687-6970
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Anesthesiology Research and Practice
spelling doaj-art-d7c764646f2343fd9c64699f7cf818712025-02-03T06:06:33ZengWileyAnesthesiology Research and Practice1687-69621687-69702020-01-01202010.1155/2020/65479276547927Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal AnesthesiaPattaraleeya Thomard0Sunthiti Morakul1Nichawan Wirachpisit2Wichai Ittichaikulthol3Chawika Pisitsak4Department of Anesthesiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Salaya, ThailandDepartment of Anesthesiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Salaya, ThailandDepartment of Anesthesiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Salaya, ThailandDepartment of Anesthesiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Salaya, ThailandDepartment of Anesthesiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Salaya, ThailandBackground. Enlarged uterus can compress the inferior vena cava and cause hypotension when lying supine. Previous studies have shown a positive association between the abdominal circumference and size of the uterus. Therefore, the aim of this study was to evaluate the relationship between abdominal circumference and incidence of hypotension during cesarean section under spinal anesthesia. Methods. The study cohort comprised women undergoing cesarean section under spinal anesthesia. Patients were divided into two groups according to the median abdominal circumference (<101 cm and ≥101 cm). Hypotension was defined as a systolic blood pressure of <90 mmHg or mean arterial pressure of <65 mmHg. The primary outcome of this study was the relationship between the incidence of hypotension and the abdominal circumference after spinal anesthesia in term pregnant women. Results. The study cohort comprised 100 women. The incidence of hypotension did not differ between the groups (71.42% in the smaller vs. 78.43% in the larger abdominal circumference group, p=0.419). However, the decrease in mean arterial pressure and its percentage decrease from baseline were greater in the larger than in the smaller abdominal circumference group (change in mean arterial pressure: 28.33 mmHg (18.66–33.67) in the smaller vs. 36.67 mmHg (23.34–43.34) in the larger abdominal circumference group, p=0.004; percentage decrease: 31.41% (22.74–39.22) in the smaller vs. 38.47% (28.00–44.81) in the larger abdominal circumference group, p=0.022). Conclusions. Large abdominal circumference in pregnancy is associated with greater decreases in mean arterial pressure from baseline. However, the incidence of hypotension defined by standard criteria did not differ between larger and smaller abdominal circumference groups.http://dx.doi.org/10.1155/2020/6547927
spellingShingle Pattaraleeya Thomard
Sunthiti Morakul
Nichawan Wirachpisit
Wichai Ittichaikulthol
Chawika Pisitsak
Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal Anesthesia
Anesthesiology Research and Practice
title Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal Anesthesia
title_full Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal Anesthesia
title_fullStr Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal Anesthesia
title_full_unstemmed Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal Anesthesia
title_short Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal Anesthesia
title_sort relationship between abdominal circumference and incidence of hypotension during cesarean section under spinal anesthesia
url http://dx.doi.org/10.1155/2020/6547927
work_keys_str_mv AT pattaraleeyathomard relationshipbetweenabdominalcircumferenceandincidenceofhypotensionduringcesareansectionunderspinalanesthesia
AT sunthitimorakul relationshipbetweenabdominalcircumferenceandincidenceofhypotensionduringcesareansectionunderspinalanesthesia
AT nichawanwirachpisit relationshipbetweenabdominalcircumferenceandincidenceofhypotensionduringcesareansectionunderspinalanesthesia
AT wichaiittichaikulthol relationshipbetweenabdominalcircumferenceandincidenceofhypotensionduringcesareansectionunderspinalanesthesia
AT chawikapisitsak relationshipbetweenabdominalcircumferenceandincidenceofhypotensionduringcesareansectionunderspinalanesthesia