PERFORMANCE IMPROVEMENT OF FEMTOSECOND PULSES SELECTION DEVICE FOR CHEMICAL PROCESSES REMOTE SPECTROMETRIC CONTROL

Results of switching velocity performance improvement for high voltage switches based on MOSFTEs are presented. Parameters of developed Q-switch driver for femtosecond laser pulse picker to use at remote spectrometric control laser radiation unit are given. Miller effect influence for high voltage M...

Full description

Saved in:
Bibliographic Details
Main Authors: K. V. Melnikov, V. A. Melnikov
Format: Article
Language:Russian
Published: Educational institution «Belarusian State University of Informatics and Radioelectronics» 2019-06-01
Series:Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
Subjects:
Online Access:https://doklady.bsuir.by/jour/article/view/575
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849336077101301760
author K. V. Melnikov
V. A. Melnikov
author_facet K. V. Melnikov
V. A. Melnikov
author_sort K. V. Melnikov
collection DOAJ
description Results of switching velocity performance improvement for high voltage switches based on MOSFTEs are presented. Parameters of developed Q-switch driver for femtosecond laser pulse picker to use at remote spectrometric control laser radiation unit are given. Miller effect influence for high voltage MOSFET switching speed experimentally investigated.
format Article
id doaj-art-d6e96a94fb5848feab1ecfdfe19bb79d
institution Kabale University
issn 1729-7648
language Russian
publishDate 2019-06-01
publisher Educational institution «Belarusian State University of Informatics and Radioelectronics»
record_format Article
series Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
spelling doaj-art-d6e96a94fb5848feab1ecfdfe19bb79d2025-08-20T03:45:06ZrusEducational institution «Belarusian State University of Informatics and Radioelectronics»Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki1729-76482019-06-01078791574PERFORMANCE IMPROVEMENT OF FEMTOSECOND PULSES SELECTION DEVICE FOR CHEMICAL PROCESSES REMOTE SPECTROMETRIC CONTROLK. V. Melnikov0V. A. Melnikov1ООО «Лазерные и информационные технологии»Белорусский государственный университет информатики и радиоэлектроникиResults of switching velocity performance improvement for high voltage switches based on MOSFTEs are presented. Parameters of developed Q-switch driver for femtosecond laser pulse picker to use at remote spectrometric control laser radiation unit are given. Miller effect influence for high voltage MOSFET switching speed experimentally investigated.https://doklady.bsuir.by/jour/article/view/575электрооптический модулятор добротностимоп-транзисторфемтосекундный лазерлазерная спектроскопия
spellingShingle K. V. Melnikov
V. A. Melnikov
PERFORMANCE IMPROVEMENT OF FEMTOSECOND PULSES SELECTION DEVICE FOR CHEMICAL PROCESSES REMOTE SPECTROMETRIC CONTROL
Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
электрооптический модулятор добротности
моп-транзистор
фемтосекундный лазер
лазерная спектроскопия
title PERFORMANCE IMPROVEMENT OF FEMTOSECOND PULSES SELECTION DEVICE FOR CHEMICAL PROCESSES REMOTE SPECTROMETRIC CONTROL
title_full PERFORMANCE IMPROVEMENT OF FEMTOSECOND PULSES SELECTION DEVICE FOR CHEMICAL PROCESSES REMOTE SPECTROMETRIC CONTROL
title_fullStr PERFORMANCE IMPROVEMENT OF FEMTOSECOND PULSES SELECTION DEVICE FOR CHEMICAL PROCESSES REMOTE SPECTROMETRIC CONTROL
title_full_unstemmed PERFORMANCE IMPROVEMENT OF FEMTOSECOND PULSES SELECTION DEVICE FOR CHEMICAL PROCESSES REMOTE SPECTROMETRIC CONTROL
title_short PERFORMANCE IMPROVEMENT OF FEMTOSECOND PULSES SELECTION DEVICE FOR CHEMICAL PROCESSES REMOTE SPECTROMETRIC CONTROL
title_sort performance improvement of femtosecond pulses selection device for chemical processes remote spectrometric control
topic электрооптический модулятор добротности
моп-транзистор
фемтосекундный лазер
лазерная спектроскопия
url https://doklady.bsuir.by/jour/article/view/575
work_keys_str_mv AT kvmelnikov performanceimprovementoffemtosecondpulsesselectiondeviceforchemicalprocessesremotespectrometriccontrol
AT vamelnikov performanceimprovementoffemtosecondpulsesselectiondeviceforchemicalprocessesremotespectrometriccontrol