Disturbance Source Location in Power Systems Based on Time Difference of Arrival

The system frequency dynamics in large-scale interconnected power grids are characterized by spatial-temporal distribution, and its propagation speed is far less than the light speed. In this paper, the propagation characteristics of dynamic frequency and the response time difference at different lo...

Full description

Saved in:
Bibliographic Details
Main Authors: Mengxi WEI, Ningning MA, Delin WANG, Wei DENG, Jitao KANG
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2019-12-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201806117
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850053437351264256
author Mengxi WEI
Ningning MA
Delin WANG
Wei DENG
Jitao KANG
author_facet Mengxi WEI
Ningning MA
Delin WANG
Wei DENG
Jitao KANG
author_sort Mengxi WEI
collection DOAJ
description The system frequency dynamics in large-scale interconnected power grids are characterized by spatial-temporal distribution, and its propagation speed is far less than the light speed. In this paper, the propagation characteristics of dynamic frequency and the response time difference at different locations are used to locate the disturbance sources. Firstly, the Floyd algorithm is used to calculate the shortest propagation path between different locations, and the propagation speed is determined according to the physical parameters of the power grid. And then, the time difference of arrival (TDOA) location method is used to locate the disturbance sources. Finally, the proposed method is applied to the 3-machine 9-bus system and the actual power grid system. The analysis results show that the proposed method can effectively locate the disturbance sources in the power grid.
format Article
id doaj-art-d69e4396dbaf4525856546973fed7d26
institution DOAJ
issn 1004-9649
language zho
publishDate 2019-12-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-d69e4396dbaf4525856546973fed7d262025-08-20T02:52:31ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492019-12-015212627010.11930/j.issn.1004-9649.201806117zgdl-52-7-weimengxiDisturbance Source Location in Power Systems Based on Time Difference of ArrivalMengxi WEI0Ningning MA1Delin WANG2Wei DENG3Jitao KANG4School of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaSchool of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaThe system frequency dynamics in large-scale interconnected power grids are characterized by spatial-temporal distribution, and its propagation speed is far less than the light speed. In this paper, the propagation characteristics of dynamic frequency and the response time difference at different locations are used to locate the disturbance sources. Firstly, the Floyd algorithm is used to calculate the shortest propagation path between different locations, and the propagation speed is determined according to the physical parameters of the power grid. And then, the time difference of arrival (TDOA) location method is used to locate the disturbance sources. Finally, the proposed method is applied to the 3-machine 9-bus system and the actual power grid system. The analysis results show that the proposed method can effectively locate the disturbance sources in the power grid.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201806117frequency dynamicpropagation characteristicstdoa methodfloyd algorithmdisturbance source location
spellingShingle Mengxi WEI
Ningning MA
Delin WANG
Wei DENG
Jitao KANG
Disturbance Source Location in Power Systems Based on Time Difference of Arrival
Zhongguo dianli
frequency dynamic
propagation characteristics
tdoa method
floyd algorithm
disturbance source location
title Disturbance Source Location in Power Systems Based on Time Difference of Arrival
title_full Disturbance Source Location in Power Systems Based on Time Difference of Arrival
title_fullStr Disturbance Source Location in Power Systems Based on Time Difference of Arrival
title_full_unstemmed Disturbance Source Location in Power Systems Based on Time Difference of Arrival
title_short Disturbance Source Location in Power Systems Based on Time Difference of Arrival
title_sort disturbance source location in power systems based on time difference of arrival
topic frequency dynamic
propagation characteristics
tdoa method
floyd algorithm
disturbance source location
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201806117
work_keys_str_mv AT mengxiwei disturbancesourcelocationinpowersystemsbasedontimedifferenceofarrival
AT ningningma disturbancesourcelocationinpowersystemsbasedontimedifferenceofarrival
AT delinwang disturbancesourcelocationinpowersystemsbasedontimedifferenceofarrival
AT weideng disturbancesourcelocationinpowersystemsbasedontimedifferenceofarrival
AT jitaokang disturbancesourcelocationinpowersystemsbasedontimedifferenceofarrival