Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth

Purpose: to evaluate the effect of the etching time and adhesive systems on the shear bond strength in primary teeth. Methodology: 48 sound primary teeth (USP teeth bank) were used. They were longitudinally sectioned (mesio-distal direction) and embedded in epoxy resin, leaving the buccal or lingual...

Full description

Saved in:
Bibliographic Details
Main Authors: Regina Maria P. Rontani, Angela S. Caldo Teixeira, Mário Alexandre C. Sinhoreti, Lourenço C. Sobrinho
Format: Article
Language:English
Published: Universidade Estadual Paulista 2010-08-01
Series:Brazilian Dental Science
Online Access:https://ojs.ict.unesp.br/index.php/cob/article/view/302
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849228758343483392
author Regina Maria P. Rontani
Angela S. Caldo Teixeira
Mário Alexandre C. Sinhoreti
Lourenço C. Sobrinho
author_facet Regina Maria P. Rontani
Angela S. Caldo Teixeira
Mário Alexandre C. Sinhoreti
Lourenço C. Sobrinho
author_sort Regina Maria P. Rontani
collection DOAJ
description Purpose: to evaluate the effect of the etching time and adhesive systems on the shear bond strength in primary teeth. Methodology: 48 sound primary teeth (USP teeth bank) were used. They were longitudinally sectioned (mesio-distal direction) and embedded in epoxy resin, leaving the buccal or lingual surface externally. The specimens were ground flat until dentin. They were randomly divided into 3 groups according to the etching time (7, 15 and 20 s) and the adhesive system used (Scotchbond Multipurpose Plus - SBMP and Prime & Bond 2.1 - PB): G1 - 7s + SBMP; G2 - 15 s + SBMP; G3 - 20 s + SBMP; G4 - 7 s + PB; G5 - 15 s + PB; G6 - 20 s + PB. Next the teeth were restored (Z100), on the dentin surface and stored in distilled water (37oC, for 72h). Then, the specimens were submitted to the SBS test in an Instron machine (0.5 mm/min). The fracture sites were analyzed in a Stereomicroscopic and SEM. The values for the SBS test were submitted to ANOVA and Tukey tests (p<0.05). Results: the SBS was higher for the 7s time groups. However, no statistical difference was observed when SB was used. The PB system showed higher values of SBS at 7 and 15s (p<0.05). The adhesive failure (86.5%) was more frequent. Conclusion: 1 - The interaction material versus time showed that for the SBMP the performance of the system did not vary due to the etching time, while for the PB the best results were found for the lower times of acid etching; 2 - The analysis of fractured sites showed that the most frequently failure type found was the adhesive type (86.5%); 3 - The larger the etching time the lower the shear bond strength values for the PB adhesive system.
format Article
id doaj-art-d690fff133ec4342bcb9d7493a90646d
institution Kabale University
issn 2178-6011
language English
publishDate 2010-08-01
publisher Universidade Estadual Paulista
record_format Article
series Brazilian Dental Science
spelling doaj-art-d690fff133ec4342bcb9d7493a90646d2025-08-22T17:32:21ZengUniversidade Estadual PaulistaBrazilian Dental Science2178-60112010-08-017310.14295/bds.2004.v7i3.302Etching time evaluation on the shear bond strength of two adhesive systems in primary teethRegina Maria P. Rontani0Angela S. Caldo Teixeira1Mário Alexandre C. Sinhoreti2Lourenço C. Sobrinho3Dental School of Piracicaba – UNICAMPDental School of Piracicaba – UNICAMPDental School of Piracicaba – UNICAMPDental School of Piracicaba – UNICAMPPurpose: to evaluate the effect of the etching time and adhesive systems on the shear bond strength in primary teeth. Methodology: 48 sound primary teeth (USP teeth bank) were used. They were longitudinally sectioned (mesio-distal direction) and embedded in epoxy resin, leaving the buccal or lingual surface externally. The specimens were ground flat until dentin. They were randomly divided into 3 groups according to the etching time (7, 15 and 20 s) and the adhesive system used (Scotchbond Multipurpose Plus - SBMP and Prime & Bond 2.1 - PB): G1 - 7s + SBMP; G2 - 15 s + SBMP; G3 - 20 s + SBMP; G4 - 7 s + PB; G5 - 15 s + PB; G6 - 20 s + PB. Next the teeth were restored (Z100), on the dentin surface and stored in distilled water (37oC, for 72h). Then, the specimens were submitted to the SBS test in an Instron machine (0.5 mm/min). The fracture sites were analyzed in a Stereomicroscopic and SEM. The values for the SBS test were submitted to ANOVA and Tukey tests (p<0.05). Results: the SBS was higher for the 7s time groups. However, no statistical difference was observed when SB was used. The PB system showed higher values of SBS at 7 and 15s (p<0.05). The adhesive failure (86.5%) was more frequent. Conclusion: 1 - The interaction material versus time showed that for the SBMP the performance of the system did not vary due to the etching time, while for the PB the best results were found for the lower times of acid etching; 2 - The analysis of fractured sites showed that the most frequently failure type found was the adhesive type (86.5%); 3 - The larger the etching time the lower the shear bond strength values for the PB adhesive system.https://ojs.ict.unesp.br/index.php/cob/article/view/302
spellingShingle Regina Maria P. Rontani
Angela S. Caldo Teixeira
Mário Alexandre C. Sinhoreti
Lourenço C. Sobrinho
Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth
Brazilian Dental Science
title Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth
title_full Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth
title_fullStr Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth
title_full_unstemmed Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth
title_short Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth
title_sort etching time evaluation on the shear bond strength of two adhesive systems in primary teeth
url https://ojs.ict.unesp.br/index.php/cob/article/view/302
work_keys_str_mv AT reginamariaprontani etchingtimeevaluationontheshearbondstrengthoftwoadhesivesystemsinprimaryteeth
AT angelascaldoteixeira etchingtimeevaluationontheshearbondstrengthoftwoadhesivesystemsinprimaryteeth
AT marioalexandrecsinhoreti etchingtimeevaluationontheshearbondstrengthoftwoadhesivesystemsinprimaryteeth
AT lourencocsobrinho etchingtimeevaluationontheshearbondstrengthoftwoadhesivesystemsinprimaryteeth