Analysis of organic acids in high-temperature Daqu based on UPLC-MS/MS technology

A method for simultaneous determination of 11 organic acids (citric acid, isocitric acid, tartaric acid, succinic acid, malic acid, malonic acid, lactic acid, adipic acid, maleic acid, fumaric acid and ascorbic acid) in high-temperature Daqu was established using ultra-high performance liquid chroma...

Full description

Saved in:
Bibliographic Details
Main Author: NIE Ye, JIAO Fu, LI Daixin, FANG Cheng, LI Qiaoyu, SUN Shiguang, XIAO Xu, TAN Xue, CHEN Maofei, MOU Mingyue
Format: Article
Language:English
Published: Editorial Department of China Brewing 2025-05-01
Series:Zhongguo niangzao
Subjects:
Online Access:https://manu61.magtech.com.cn/zgnz/fileup/0254-5071/PDF/0254-5071-2025-44-5-278.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849425006880096256
author NIE Ye, JIAO Fu, LI Daixin, FANG Cheng, LI Qiaoyu, SUN Shiguang, XIAO Xu, TAN Xue, CHEN Maofei, MOU Mingyue
author_facet NIE Ye, JIAO Fu, LI Daixin, FANG Cheng, LI Qiaoyu, SUN Shiguang, XIAO Xu, TAN Xue, CHEN Maofei, MOU Mingyue
author_sort NIE Ye, JIAO Fu, LI Daixin, FANG Cheng, LI Qiaoyu, SUN Shiguang, XIAO Xu, TAN Xue, CHEN Maofei, MOU Mingyue
collection DOAJ
description A method for simultaneous determination of 11 organic acids (citric acid, isocitric acid, tartaric acid, succinic acid, malic acid, malonic acid, lactic acid, adipic acid, maleic acid, fumaric acid and ascorbic acid) in high-temperature Daqu was established using ultra-high performance liquid chromatography triple quadrupole tandem mass spectrometry (UPLC-MS/MS). The high-temperature Daqu sample was extracted and diluted with water, separated by Accucore aQ chromatography column (150 mm&#x00D7;2.1 mm, 2.6 μm), eluted with a gradient of methanol-0.2% formic acid water as the mobile phase at a flow rate of 400 μl/min and column temperature of 40 ℃, determined by negative ion multiple reaction monitoring mode (MRM), and quantified by the matrix external standard method. The results showed that the 11 organic acids had good linear relationships within their respective mass concentration ranges, with correlation coefficients R<sup>2</sup>≥0.996, the detection limit (LOD) were 0.08-4.13 μg/kg, the quantification limit (LOQ) were 0.27-13.76 μg/kg, the average recovery rates were 77.0%-113.0%, and the relative standard deviation (RSD) of precision tests results were 0.1%-11.5%. This method had simple pretreatment, short analysis time, high accuracy, and good repeatability, which was suitable for analyzing the contents of 11 organic acids in high-temperature Daqu samples.
format Article
id doaj-art-d65d208deebf41c99d7ed54003bb4428
institution Kabale University
issn 0254-5071
language English
publishDate 2025-05-01
publisher Editorial Department of China Brewing
record_format Article
series Zhongguo niangzao
spelling doaj-art-d65d208deebf41c99d7ed54003bb44282025-08-20T03:29:56ZengEditorial Department of China BrewingZhongguo niangzao0254-50712025-05-0144527828310.11882/j.issn.0254-5071.2025.05.041Analysis of organic acids in high-temperature Daqu based on UPLC-MS/MS technologyNIE Ye, JIAO Fu, LI Daixin, FANG Cheng, LI Qiaoyu, SUN Shiguang, XIAO Xu, TAN Xue, CHEN Maofei, MOU Mingyue01. Kweichow Moutai Co., Ltd., Zunyi 564501, China; ;2. Guizhou Brewing Engineering Technology Research Center, Zunyi 564501, ChinaA method for simultaneous determination of 11 organic acids (citric acid, isocitric acid, tartaric acid, succinic acid, malic acid, malonic acid, lactic acid, adipic acid, maleic acid, fumaric acid and ascorbic acid) in high-temperature Daqu was established using ultra-high performance liquid chromatography triple quadrupole tandem mass spectrometry (UPLC-MS/MS). The high-temperature Daqu sample was extracted and diluted with water, separated by Accucore aQ chromatography column (150 mm&#x00D7;2.1 mm, 2.6 μm), eluted with a gradient of methanol-0.2% formic acid water as the mobile phase at a flow rate of 400 μl/min and column temperature of 40 ℃, determined by negative ion multiple reaction monitoring mode (MRM), and quantified by the matrix external standard method. The results showed that the 11 organic acids had good linear relationships within their respective mass concentration ranges, with correlation coefficients R<sup>2</sup>≥0.996, the detection limit (LOD) were 0.08-4.13 μg/kg, the quantification limit (LOQ) were 0.27-13.76 μg/kg, the average recovery rates were 77.0%-113.0%, and the relative standard deviation (RSD) of precision tests results were 0.1%-11.5%. This method had simple pretreatment, short analysis time, high accuracy, and good repeatability, which was suitable for analyzing the contents of 11 organic acids in high-temperature Daqu samples.https://manu61.magtech.com.cn/zgnz/fileup/0254-5071/PDF/0254-5071-2025-44-5-278.pdfultra-high performance liquid chromatography tandem mass spectrometry|high-temperature daqu|organic acids
spellingShingle NIE Ye, JIAO Fu, LI Daixin, FANG Cheng, LI Qiaoyu, SUN Shiguang, XIAO Xu, TAN Xue, CHEN Maofei, MOU Mingyue
Analysis of organic acids in high-temperature Daqu based on UPLC-MS/MS technology
Zhongguo niangzao
ultra-high performance liquid chromatography tandem mass spectrometry|high-temperature daqu|organic acids
title Analysis of organic acids in high-temperature Daqu based on UPLC-MS/MS technology
title_full Analysis of organic acids in high-temperature Daqu based on UPLC-MS/MS technology
title_fullStr Analysis of organic acids in high-temperature Daqu based on UPLC-MS/MS technology
title_full_unstemmed Analysis of organic acids in high-temperature Daqu based on UPLC-MS/MS technology
title_short Analysis of organic acids in high-temperature Daqu based on UPLC-MS/MS technology
title_sort analysis of organic acids in high temperature daqu based on uplc ms ms technology
topic ultra-high performance liquid chromatography tandem mass spectrometry|high-temperature daqu|organic acids
url https://manu61.magtech.com.cn/zgnz/fileup/0254-5071/PDF/0254-5071-2025-44-5-278.pdf
work_keys_str_mv AT nieyejiaofulidaixinfangchengliqiaoyusunshiguangxiaoxutanxuechenmaofeimoumingyue analysisoforganicacidsinhightemperaturedaqubasedonuplcmsmstechnology