Use of Ultra-Hydrophilic Absorbable Polysaccharide for Bleeding Control in Cardiothoracic Surgical Procedures

<i>Background and Objectives:</i> Operative blood loss is strongly correlated with morbidity and mortality in surgery. Various hemostatic agents are used to reduce bleeding in cardiothoracic procedures. We report our experience with a plant-based microporous polysaccharide hemostatic pow...

Full description

Saved in:
Bibliographic Details
Main Authors: Dow Rosenzweig, Peter Lamm, Christoph Schmitz, Ferdinand Vogt
Format: Article
Language:English
Published: MDPI AG 2025-01-01
Series:Medicina
Subjects:
Online Access:https://www.mdpi.com/1648-9144/61/2/230
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850229728050413568
author Dow Rosenzweig
Peter Lamm
Christoph Schmitz
Ferdinand Vogt
author_facet Dow Rosenzweig
Peter Lamm
Christoph Schmitz
Ferdinand Vogt
author_sort Dow Rosenzweig
collection DOAJ
description <i>Background and Objectives:</i> Operative blood loss is strongly correlated with morbidity and mortality in surgery. Various hemostatic agents are used to reduce bleeding in cardiothoracic procedures. We report our experience with a plant-based microporous polysaccharide hemostatic powder (Starsil<sup>®</sup> Hemostat, Hemostat Medical GmbH, Velen, Germany). <i>Materials and Methods:</i> Data were collected retrospectively from 65 patients who underwent cardiac surgery at our institution from January 2012 to January 2015 with (<i>n</i> = 42) or without (<i>n</i> = 23; control group) the use of the hemostat powder. Primary endpoints were safety (e.g., laboratory parameters, adverse events, and infection parameters) and time to hemostasis when the hemostat powder was used. Other endpoints included operation time, hospitalization, quantity of the hemostat powder applied, and length of stay in the intensive care unit. <i>Results:</i> The 65 patients (49 male:16 female) analyzed in the study underwent 65 cardiothoracic procedures, including off-pump coronary artery bypass grafts (<i>n</i> = 25), on-pump coronary artery bypass grafts (<i>n</i> = 6), valve procedures (<i>n</i> = 6), valve procedures in combination with bypass grafts (<i>n</i> = 7), and others (<i>n</i> = 21). The application of the hemostat powder did not increase adverse events. The laboratory parameters did not exceed the expected range after heart surgery in both groups. The hemostat powder had no significant impact on the laboratory parameters compared to the control group. Blood control was sufficient and was rated by surgeons from good to very good on a visual analog scale (VAS) from 1 (very bad) to 10 (very good) [VAS = 8.3 ± 1.2]. Intraoperative hemostasis was possible in nearly all patients. The hemostat powder led to satisfactory bleeding control within 2 min in 88% of cases. Five patients needed a second 5 g unit of the hemostat powder. <i>Conclusions:</i> The observed parameters between groups did not differ significantly. Therefore, the use of Starsil<sup>®</sup> Hemostat in cardiothoracic surgery is safe and effective bleeding control was achieved.
format Article
id doaj-art-d5d012519e4341449f9dafa52a1d8b6d
institution OA Journals
issn 1010-660X
1648-9144
language English
publishDate 2025-01-01
publisher MDPI AG
record_format Article
series Medicina
spelling doaj-art-d5d012519e4341449f9dafa52a1d8b6d2025-08-20T02:04:06ZengMDPI AGMedicina1010-660X1648-91442025-01-0161223010.3390/medicina61020230Use of Ultra-Hydrophilic Absorbable Polysaccharide for Bleeding Control in Cardiothoracic Surgical ProceduresDow Rosenzweig0Peter Lamm1Christoph Schmitz2Ferdinand Vogt3Department of Cardiac Surgery, Artemed Klinikum München Süd, 81379 Munich, GermanyDepartment of Cardiac Surgery, Artemed Klinikum München Süd, 81379 Munich, GermanyDepartment of Cardiac Surgery, University of Munich, 81377 Munich, GermanyDepartment of Cardiac Surgery, Artemed Klinikum München Süd, 81379 Munich, Germany<i>Background and Objectives:</i> Operative blood loss is strongly correlated with morbidity and mortality in surgery. Various hemostatic agents are used to reduce bleeding in cardiothoracic procedures. We report our experience with a plant-based microporous polysaccharide hemostatic powder (Starsil<sup>®</sup> Hemostat, Hemostat Medical GmbH, Velen, Germany). <i>Materials and Methods:</i> Data were collected retrospectively from 65 patients who underwent cardiac surgery at our institution from January 2012 to January 2015 with (<i>n</i> = 42) or without (<i>n</i> = 23; control group) the use of the hemostat powder. Primary endpoints were safety (e.g., laboratory parameters, adverse events, and infection parameters) and time to hemostasis when the hemostat powder was used. Other endpoints included operation time, hospitalization, quantity of the hemostat powder applied, and length of stay in the intensive care unit. <i>Results:</i> The 65 patients (49 male:16 female) analyzed in the study underwent 65 cardiothoracic procedures, including off-pump coronary artery bypass grafts (<i>n</i> = 25), on-pump coronary artery bypass grafts (<i>n</i> = 6), valve procedures (<i>n</i> = 6), valve procedures in combination with bypass grafts (<i>n</i> = 7), and others (<i>n</i> = 21). The application of the hemostat powder did not increase adverse events. The laboratory parameters did not exceed the expected range after heart surgery in both groups. The hemostat powder had no significant impact on the laboratory parameters compared to the control group. Blood control was sufficient and was rated by surgeons from good to very good on a visual analog scale (VAS) from 1 (very bad) to 10 (very good) [VAS = 8.3 ± 1.2]. Intraoperative hemostasis was possible in nearly all patients. The hemostat powder led to satisfactory bleeding control within 2 min in 88% of cases. Five patients needed a second 5 g unit of the hemostat powder. <i>Conclusions:</i> The observed parameters between groups did not differ significantly. Therefore, the use of Starsil<sup>®</sup> Hemostat in cardiothoracic surgery is safe and effective bleeding control was achieved.https://www.mdpi.com/1648-9144/61/2/230Starsil<sup>®</sup> Hemostatbleeding controlplant-based microporous polysaccharidepolysaccharidehemostatic powdercardiac surgery
spellingShingle Dow Rosenzweig
Peter Lamm
Christoph Schmitz
Ferdinand Vogt
Use of Ultra-Hydrophilic Absorbable Polysaccharide for Bleeding Control in Cardiothoracic Surgical Procedures
Medicina
Starsil<sup>®</sup> Hemostat
bleeding control
plant-based microporous polysaccharide
polysaccharide
hemostatic powder
cardiac surgery
title Use of Ultra-Hydrophilic Absorbable Polysaccharide for Bleeding Control in Cardiothoracic Surgical Procedures
title_full Use of Ultra-Hydrophilic Absorbable Polysaccharide for Bleeding Control in Cardiothoracic Surgical Procedures
title_fullStr Use of Ultra-Hydrophilic Absorbable Polysaccharide for Bleeding Control in Cardiothoracic Surgical Procedures
title_full_unstemmed Use of Ultra-Hydrophilic Absorbable Polysaccharide for Bleeding Control in Cardiothoracic Surgical Procedures
title_short Use of Ultra-Hydrophilic Absorbable Polysaccharide for Bleeding Control in Cardiothoracic Surgical Procedures
title_sort use of ultra hydrophilic absorbable polysaccharide for bleeding control in cardiothoracic surgical procedures
topic Starsil<sup>®</sup> Hemostat
bleeding control
plant-based microporous polysaccharide
polysaccharide
hemostatic powder
cardiac surgery
url https://www.mdpi.com/1648-9144/61/2/230
work_keys_str_mv AT dowrosenzweig useofultrahydrophilicabsorbablepolysaccharideforbleedingcontrolincardiothoracicsurgicalprocedures
AT peterlamm useofultrahydrophilicabsorbablepolysaccharideforbleedingcontrolincardiothoracicsurgicalprocedures
AT christophschmitz useofultrahydrophilicabsorbablepolysaccharideforbleedingcontrolincardiothoracicsurgicalprocedures
AT ferdinandvogt useofultrahydrophilicabsorbablepolysaccharideforbleedingcontrolincardiothoracicsurgicalprocedures