Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger

This investigation is specifically centered on quantitatively assessing the heat transfer and fluid movement within a shell and spiral tube heat exchanger comprising three distinct designs. Water was considered as the heat transfer fluid, operating within the spiral coil and the shell. In this setup...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmed Mir, Seyed Hossein Hashemi Karouei, Rassol Hamed Rasheed, Pradeep Kumar Singh, Saurav Dixit, Rifaqat Ali, Walid Aich, Lioua Kolsi
Format: Article
Language:English
Published: Elsevier 2025-06-01
Series:Case Studies in Thermal Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X25003387
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850280986020937728
author Ahmed Mir
Seyed Hossein Hashemi Karouei
Rassol Hamed Rasheed
Pradeep Kumar Singh
Saurav Dixit
Rifaqat Ali
Walid Aich
Lioua Kolsi
author_facet Ahmed Mir
Seyed Hossein Hashemi Karouei
Rassol Hamed Rasheed
Pradeep Kumar Singh
Saurav Dixit
Rifaqat Ali
Walid Aich
Lioua Kolsi
author_sort Ahmed Mir
collection DOAJ
description This investigation is specifically centered on quantitatively assessing the heat transfer and fluid movement within a shell and spiral tube heat exchanger comprising three distinct designs. Water was considered as the heat transfer fluid, operating within the spiral coil and the shell. In this setup, the hot fluid circulates inside the coil while the cold fluid is contained within the shell. The research covers a range of Reynolds numbers from 500 to 2000 and is split into two parts. The first part of the study examines the impact of three different spiral coil models and evaluates their thermal performance. In the second part, the best spiral coil is selected based on the findings from the first part. Three different spiral winding pitches (P) are considered: 60 mm, 50 mm, and 40 mm, with the results compared to those of a simple winding. Among the three models analyzed in the first part, model (A) with a special helical coil design exhibited the greatest thermal productivity across different Reynolds numbers. Findings showed that the helical coil with the model (A) design enhances the energy exchange between hot and cold fluid particles owing to the reinforcement of centrifugal force, intensified secondary flow, and improved radial mixing of particles. As a result, this particular coil displayed significant thermal perform effectiveness because of the intensified vortex movement of liquid particles and the thinning of thermal boundary layers. The second part of the study revealed that the thermal performance of the spiral coil with a 60 mm pitch surpassed that of the other two models. At a Reynolds number of 500, it was observed that the thermal performance coefficient increased by 60 % for the model with a 60 mm pitch, 45 % for the model with a 50 mm pitch, and 28.8 % for the model with a 40 mm pitch. This indicates a significant improvement in thermal performance as the pitch size decreases.
format Article
id doaj-art-d5ce0fda1d7443b79c1580f5ba60bf56
institution OA Journals
issn 2214-157X
language English
publishDate 2025-06-01
publisher Elsevier
record_format Article
series Case Studies in Thermal Engineering
spelling doaj-art-d5ce0fda1d7443b79c1580f5ba60bf562025-08-20T01:48:30ZengElsevierCase Studies in Thermal Engineering2214-157X2025-06-017010607810.1016/j.csite.2025.106078Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchangerAhmed Mir0Seyed Hossein Hashemi Karouei1Rassol Hamed Rasheed2Pradeep Kumar Singh3Saurav Dixit4Rifaqat Ali5Walid Aich6Lioua Kolsi7Department of Chemical and Materials Engineering, College of Engineering, Northern Border University, Arar P.O. Box 1321, Saudi ArabiaFaculty of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, 47148-71167, Iran; Corresponding author.Air Conditioning Engineering Department, Faculty of Engineering, Warith Al-Anbiyaa University, IraqDepartment of Mechanical Engineering, Institute of Engineering and Technology, GLA University, Mathura, U.P, IndiaCentre of Research Impact and Outcome, Chitkara University, Rajpura, 140417, Punjab, IndiaDepartment of Mathematics, Applied College in Mohayil Asir, King Khalid University, Abha, Saudi ArabiaDepartment of Mechanical Engineering, College of Engineering, University of Ha'il, Ha'il City, 81451, Saudi ArabiaDepartment of Mechanical Engineering, College of Engineering, University of Ha'il, Ha'il City, 81451, Saudi ArabiaThis investigation is specifically centered on quantitatively assessing the heat transfer and fluid movement within a shell and spiral tube heat exchanger comprising three distinct designs. Water was considered as the heat transfer fluid, operating within the spiral coil and the shell. In this setup, the hot fluid circulates inside the coil while the cold fluid is contained within the shell. The research covers a range of Reynolds numbers from 500 to 2000 and is split into two parts. The first part of the study examines the impact of three different spiral coil models and evaluates their thermal performance. In the second part, the best spiral coil is selected based on the findings from the first part. Three different spiral winding pitches (P) are considered: 60 mm, 50 mm, and 40 mm, with the results compared to those of a simple winding. Among the three models analyzed in the first part, model (A) with a special helical coil design exhibited the greatest thermal productivity across different Reynolds numbers. Findings showed that the helical coil with the model (A) design enhances the energy exchange between hot and cold fluid particles owing to the reinforcement of centrifugal force, intensified secondary flow, and improved radial mixing of particles. As a result, this particular coil displayed significant thermal perform effectiveness because of the intensified vortex movement of liquid particles and the thinning of thermal boundary layers. The second part of the study revealed that the thermal performance of the spiral coil with a 60 mm pitch surpassed that of the other two models. At a Reynolds number of 500, it was observed that the thermal performance coefficient increased by 60 % for the model with a 60 mm pitch, 45 % for the model with a 50 mm pitch, and 28.8 % for the model with a 40 mm pitch. This indicates a significant improvement in thermal performance as the pitch size decreases.http://www.sciencedirect.com/science/article/pii/S2214157X25003387HydrothermalNumerical modelHeat exchangerShell/coil tubeCFD
spellingShingle Ahmed Mir
Seyed Hossein Hashemi Karouei
Rassol Hamed Rasheed
Pradeep Kumar Singh
Saurav Dixit
Rifaqat Ali
Walid Aich
Lioua Kolsi
Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger
Case Studies in Thermal Engineering
Hydrothermal
Numerical model
Heat exchanger
Shell/coil tube
CFD
title Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger
title_full Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger
title_fullStr Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger
title_full_unstemmed Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger
title_short Numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger
title_sort numerical investigation of the effect of three types of spiral coils on the hydrothermal behavior of fluid flow in a shell and coil heat exchanger
topic Hydrothermal
Numerical model
Heat exchanger
Shell/coil tube
CFD
url http://www.sciencedirect.com/science/article/pii/S2214157X25003387
work_keys_str_mv AT ahmedmir numericalinvestigationoftheeffectofthreetypesofspiralcoilsonthehydrothermalbehavioroffluidflowinashellandcoilheatexchanger
AT seyedhosseinhashemikarouei numericalinvestigationoftheeffectofthreetypesofspiralcoilsonthehydrothermalbehavioroffluidflowinashellandcoilheatexchanger
AT rassolhamedrasheed numericalinvestigationoftheeffectofthreetypesofspiralcoilsonthehydrothermalbehavioroffluidflowinashellandcoilheatexchanger
AT pradeepkumarsingh numericalinvestigationoftheeffectofthreetypesofspiralcoilsonthehydrothermalbehavioroffluidflowinashellandcoilheatexchanger
AT sauravdixit numericalinvestigationoftheeffectofthreetypesofspiralcoilsonthehydrothermalbehavioroffluidflowinashellandcoilheatexchanger
AT rifaqatali numericalinvestigationoftheeffectofthreetypesofspiralcoilsonthehydrothermalbehavioroffluidflowinashellandcoilheatexchanger
AT walidaich numericalinvestigationoftheeffectofthreetypesofspiralcoilsonthehydrothermalbehavioroffluidflowinashellandcoilheatexchanger
AT liouakolsi numericalinvestigationoftheeffectofthreetypesofspiralcoilsonthehydrothermalbehavioroffluidflowinashellandcoilheatexchanger