Implementation of IoT-based SCADA in MPS Processing Station Integrated with CtrlX Automation

The increasing complexity of industrial automation technology today requires industries to upgrade their existing systems, such as IoT-based SCADA, which allows for real-time production monitoring from anywhere. However, to achieve this, a system is needed that does not affect or halt the production...

Full description

Saved in:
Bibliographic Details
Main Authors: Gun Gun Maulana, Ridwan Mada, Ismail Rokhim, Hendy Rudiansyah, Muhammad Giri Suhada
Format: Article
Language:English
Published: Universitas Syiah Kuala 2025-06-01
Series:Jurnal Rekayasa Elektrika
Online Access:https://jurnal.usk.ac.id/JRE/article/view/40848
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850100564799520768
author Gun Gun Maulana
Ridwan Mada
Ismail Rokhim
Hendy Rudiansyah
Muhammad Giri Suhada
author_facet Gun Gun Maulana
Ridwan Mada
Ismail Rokhim
Hendy Rudiansyah
Muhammad Giri Suhada
author_sort Gun Gun Maulana
collection DOAJ
description The increasing complexity of industrial automation technology today requires industries to upgrade their existing systems, such as IoT-based SCADA, which allows for real-time production monitoring from anywhere. However, to achieve this, a system is needed that does not affect or halt the production process and does not require replacing the existing system during the upgrade process. Therefore, a system that can adapt to the existing one is necessary. This research aims to implement an IoT-based SCADA system in an existing plant by integrating the system with ctrlX Automation to address this issue. The implementation is carried out in several stages. The first stage involves integrating the plant controlled by the Omron CP1L PLC with ctrlX Automation. The second stage is creating tags for the SCADA system using tools installed on ctrlX Automation. The third stage involves developing the user interface. The fourth stage is the remote access communication process for the IoT system using the OpenVPN Cloud tool. The test results show that the integration between the Omron CP1L PLC and ctrlX Automation was successful, with a 100% tag retrieval rate from the Omron CP1L PLC, and the data could be visualized. The user interface can be accessed, and remote access can be performed on different networks and locations using the OpenVPN Cloud tool. During testing, the average data transfer write-read delay with one address/tag during remote access was 61.3ms, and for the write-read test with three addresses simultaneously, the average was 78.1ms. Based on these results, the data transfer process using ctrlX Automation integrated with the Omron CP1L PLC can be categorized as very good.
format Article
id doaj-art-d5b62aed62504f628cbba5c11eb96bf4
institution DOAJ
issn 1412-4785
2252-620X
language English
publishDate 2025-06-01
publisher Universitas Syiah Kuala
record_format Article
series Jurnal Rekayasa Elektrika
spelling doaj-art-d5b62aed62504f628cbba5c11eb96bf42025-08-20T02:40:17ZengUniversitas Syiah KualaJurnal Rekayasa Elektrika1412-47852252-620X2025-06-0121210.17529/jre.v21i2.4084820698Implementation of IoT-based SCADA in MPS Processing Station Integrated with CtrlX AutomationGun Gun Maulana0Ridwan Mada1Ismail Rokhim2Hendy Rudiansyah3Muhammad Giri Suhada4Politeknik Manufaktur BandungPoliteknik Manufaktur BandungPoliteknik Manufaktur BandungPoliteknik Manufaktur BandungPoliteknik Manufaktur BandungThe increasing complexity of industrial automation technology today requires industries to upgrade their existing systems, such as IoT-based SCADA, which allows for real-time production monitoring from anywhere. However, to achieve this, a system is needed that does not affect or halt the production process and does not require replacing the existing system during the upgrade process. Therefore, a system that can adapt to the existing one is necessary. This research aims to implement an IoT-based SCADA system in an existing plant by integrating the system with ctrlX Automation to address this issue. The implementation is carried out in several stages. The first stage involves integrating the plant controlled by the Omron CP1L PLC with ctrlX Automation. The second stage is creating tags for the SCADA system using tools installed on ctrlX Automation. The third stage involves developing the user interface. The fourth stage is the remote access communication process for the IoT system using the OpenVPN Cloud tool. The test results show that the integration between the Omron CP1L PLC and ctrlX Automation was successful, with a 100% tag retrieval rate from the Omron CP1L PLC, and the data could be visualized. The user interface can be accessed, and remote access can be performed on different networks and locations using the OpenVPN Cloud tool. During testing, the average data transfer write-read delay with one address/tag during remote access was 61.3ms, and for the write-read test with three addresses simultaneously, the average was 78.1ms. Based on these results, the data transfer process using ctrlX Automation integrated with the Omron CP1L PLC can be categorized as very good.https://jurnal.usk.ac.id/JRE/article/view/40848
spellingShingle Gun Gun Maulana
Ridwan Mada
Ismail Rokhim
Hendy Rudiansyah
Muhammad Giri Suhada
Implementation of IoT-based SCADA in MPS Processing Station Integrated with CtrlX Automation
Jurnal Rekayasa Elektrika
title Implementation of IoT-based SCADA in MPS Processing Station Integrated with CtrlX Automation
title_full Implementation of IoT-based SCADA in MPS Processing Station Integrated with CtrlX Automation
title_fullStr Implementation of IoT-based SCADA in MPS Processing Station Integrated with CtrlX Automation
title_full_unstemmed Implementation of IoT-based SCADA in MPS Processing Station Integrated with CtrlX Automation
title_short Implementation of IoT-based SCADA in MPS Processing Station Integrated with CtrlX Automation
title_sort implementation of iot based scada in mps processing station integrated with ctrlx automation
url https://jurnal.usk.ac.id/JRE/article/view/40848
work_keys_str_mv AT gungunmaulana implementationofiotbasedscadainmpsprocessingstationintegratedwithctrlxautomation
AT ridwanmada implementationofiotbasedscadainmpsprocessingstationintegratedwithctrlxautomation
AT ismailrokhim implementationofiotbasedscadainmpsprocessingstationintegratedwithctrlxautomation
AT hendyrudiansyah implementationofiotbasedscadainmpsprocessingstationintegratedwithctrlxautomation
AT muhammadgirisuhada implementationofiotbasedscadainmpsprocessingstationintegratedwithctrlxautomation