Rapid Switch from Intra-Aortic Balloon Pumping to Percutaneous Cardiopulmonary Support Using Perclose ProGlide
We present a case of a patient who needed rapid switch from intra-aortic balloon pumping (IABP) to percutaneous cardiopulmonary support (PCPS)/venoarterial extracorporeal membrane oxygenation. It is difficult to switch from IABP to PCPS, because 0.035-inch guidewires cannot pass the IABP guidewire l...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2015-01-01
|
Series: | Case Reports in Cardiology |
Online Access: | http://dx.doi.org/10.1155/2015/407059 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832563805795647488 |
---|---|
author | Kenichi Sakakura Yusuke Adachi Yousuke Taniguchi Hiroshi Wada Shin-ichi Momomura Hideo Fujita |
author_facet | Kenichi Sakakura Yusuke Adachi Yousuke Taniguchi Hiroshi Wada Shin-ichi Momomura Hideo Fujita |
author_sort | Kenichi Sakakura |
collection | DOAJ |
description | We present a case of a patient who needed rapid switch from intra-aortic balloon pumping (IABP) to percutaneous cardiopulmonary support (PCPS)/venoarterial extracorporeal membrane oxygenation. It is difficult to switch from IABP to PCPS, because 0.035-inch guidewires cannot pass the IABP guidewire lumen (0.025-inch compatible), and the IABP sheath needs to be removed together with the IABP catheter. First, a 0.025-inch guidewire was inserted into the IABP wire lumen, and then the IABP catheter together with the 8 Fr IABP sheath was removed, leaving the 0.025-inch guidewire in place. We used the Perclose ProGlide for safe and rapid exchange of the 0.025-inch guidewire for a 0.035-inch guidewire. This allowed insertion of a PCPS cannula and the prompt initiation of PCPS. |
format | Article |
id | doaj-art-d54e254057fa41a28228c2051b8b45c0 |
institution | Kabale University |
issn | 2090-6404 2090-6412 |
language | English |
publishDate | 2015-01-01 |
publisher | Wiley |
record_format | Article |
series | Case Reports in Cardiology |
spelling | doaj-art-d54e254057fa41a28228c2051b8b45c02025-02-03T01:12:33ZengWileyCase Reports in Cardiology2090-64042090-64122015-01-01201510.1155/2015/407059407059Rapid Switch from Intra-Aortic Balloon Pumping to Percutaneous Cardiopulmonary Support Using Perclose ProGlideKenichi Sakakura0Yusuke Adachi1Yousuke Taniguchi2Hiroshi Wada3Shin-ichi Momomura4Hideo Fujita5Division of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama 330-8503, JapanDivision of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama 330-8503, JapanDivision of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama 330-8503, JapanDivision of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama 330-8503, JapanDivision of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama 330-8503, JapanDivision of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama 330-8503, JapanWe present a case of a patient who needed rapid switch from intra-aortic balloon pumping (IABP) to percutaneous cardiopulmonary support (PCPS)/venoarterial extracorporeal membrane oxygenation. It is difficult to switch from IABP to PCPS, because 0.035-inch guidewires cannot pass the IABP guidewire lumen (0.025-inch compatible), and the IABP sheath needs to be removed together with the IABP catheter. First, a 0.025-inch guidewire was inserted into the IABP wire lumen, and then the IABP catheter together with the 8 Fr IABP sheath was removed, leaving the 0.025-inch guidewire in place. We used the Perclose ProGlide for safe and rapid exchange of the 0.025-inch guidewire for a 0.035-inch guidewire. This allowed insertion of a PCPS cannula and the prompt initiation of PCPS.http://dx.doi.org/10.1155/2015/407059 |
spellingShingle | Kenichi Sakakura Yusuke Adachi Yousuke Taniguchi Hiroshi Wada Shin-ichi Momomura Hideo Fujita Rapid Switch from Intra-Aortic Balloon Pumping to Percutaneous Cardiopulmonary Support Using Perclose ProGlide Case Reports in Cardiology |
title | Rapid Switch from Intra-Aortic Balloon Pumping to Percutaneous Cardiopulmonary Support Using Perclose ProGlide |
title_full | Rapid Switch from Intra-Aortic Balloon Pumping to Percutaneous Cardiopulmonary Support Using Perclose ProGlide |
title_fullStr | Rapid Switch from Intra-Aortic Balloon Pumping to Percutaneous Cardiopulmonary Support Using Perclose ProGlide |
title_full_unstemmed | Rapid Switch from Intra-Aortic Balloon Pumping to Percutaneous Cardiopulmonary Support Using Perclose ProGlide |
title_short | Rapid Switch from Intra-Aortic Balloon Pumping to Percutaneous Cardiopulmonary Support Using Perclose ProGlide |
title_sort | rapid switch from intra aortic balloon pumping to percutaneous cardiopulmonary support using perclose proglide |
url | http://dx.doi.org/10.1155/2015/407059 |
work_keys_str_mv | AT kenichisakakura rapidswitchfromintraaorticballoonpumpingtopercutaneouscardiopulmonarysupportusingpercloseproglide AT yusukeadachi rapidswitchfromintraaorticballoonpumpingtopercutaneouscardiopulmonarysupportusingpercloseproglide AT yousuketaniguchi rapidswitchfromintraaorticballoonpumpingtopercutaneouscardiopulmonarysupportusingpercloseproglide AT hiroshiwada rapidswitchfromintraaorticballoonpumpingtopercutaneouscardiopulmonarysupportusingpercloseproglide AT shinichimomomura rapidswitchfromintraaorticballoonpumpingtopercutaneouscardiopulmonarysupportusingpercloseproglide AT hideofujita rapidswitchfromintraaorticballoonpumpingtopercutaneouscardiopulmonarysupportusingpercloseproglide |