THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHOD

The synthesis of synthetic zeolite modified biosensor material has been carried out to detect uric acid. This study aims to look at the effect of synthetic zeolite on uric acid biosensor material on sensor stability and sensitivity. The biosensor was use to measure uric acid using uricase produced L...

Full description

Saved in:
Bibliographic Details
Main Authors: Iza Faizah, Dwi Puryanti, Afdhal Muttaqin
Format: Article
Language:English
Published: Universitas Negeri Jakarta 2018-12-01
Series:Spektra: Jurnal Fisika dan Aplikasinya
Subjects:
Online Access:https://journal.unj.ac.id/unj/index.php/spektra/article/view/8648
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849683562153902080
author Iza Faizah
Dwi Puryanti
Afdhal Muttaqin
author_facet Iza Faizah
Dwi Puryanti
Afdhal Muttaqin
author_sort Iza Faizah
collection DOAJ
description The synthesis of synthetic zeolite modified biosensor material has been carried out to detect uric acid. This study aims to look at the effect of synthetic zeolite on uric acid biosensor material on sensor stability and sensitivity. The biosensor was use to measure uric acid using uricase produced Lactobacillus plantarum. Modification of biosensor material using synthetic zeolite content of Sodalit is added in a mixture of graphite and paraffin. Carbon paste electrode (EPK) was made with graphite and paraffin comparison 70 mg : 30 mg, while zeolite modified carbon paste electrode (EPKZ) with graphite, paraffin and zeolite comparison 50 mg: 30 mg: 20 mg. In each electrode, 7.5 μl of L.plantarum pellet (EPKZLP) was dropped. Electrode performance testing was carried out using Cyclic Voltammetry. Modification results affect biosensor performance such as sensitivity and stability. The highest current is produced by EPKZLP with a current range of 0.0143 - 0.0592 mA. The best sensitivity is produced in EPKZLP with a value of 0.031 mAcm-2mM-1. The best stability was found in EPKZLP with a percentage of stability on day 14 was 30.9%. The average standard deviation generated in this study is 0.0024 mA with a relative error value was 7.8%. Addition of zeolite to biosensor material produced in this study has met several criteria to be used as a sensor. Keywords: uric acid biosensor, zeolite, sodalit, sensitivity, stability.
format Article
id doaj-art-d4dacd4038c7494e95f165f174e1a6ee
institution DOAJ
issn 2541-3384
2541-3392
language English
publishDate 2018-12-01
publisher Universitas Negeri Jakarta
record_format Article
series Spektra: Jurnal Fisika dan Aplikasinya
spelling doaj-art-d4dacd4038c7494e95f165f174e1a6ee2025-08-20T03:23:50ZengUniversitas Negeri JakartaSpektra: Jurnal Fisika dan Aplikasinya2541-33842541-33922018-12-01331731806534THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHODIza Faizah0Dwi Puryanti1Afdhal Muttaqin2Jurusan Fisika, Fakultas MIPA, Universitas Andalas Padang, 25163 IndonesiaLaboratorium Teknologi Hasil Ternak, Fakultas Peternakan, Universitas Andalas Padang, 25163 IndonesiaJurusan Fisika, Fakultas MIPA, Universitas Andalas Padang, 25163 IndonesiaThe synthesis of synthetic zeolite modified biosensor material has been carried out to detect uric acid. This study aims to look at the effect of synthetic zeolite on uric acid biosensor material on sensor stability and sensitivity. The biosensor was use to measure uric acid using uricase produced Lactobacillus plantarum. Modification of biosensor material using synthetic zeolite content of Sodalit is added in a mixture of graphite and paraffin. Carbon paste electrode (EPK) was made with graphite and paraffin comparison 70 mg : 30 mg, while zeolite modified carbon paste electrode (EPKZ) with graphite, paraffin and zeolite comparison 50 mg: 30 mg: 20 mg. In each electrode, 7.5 μl of L.plantarum pellet (EPKZLP) was dropped. Electrode performance testing was carried out using Cyclic Voltammetry. Modification results affect biosensor performance such as sensitivity and stability. The highest current is produced by EPKZLP with a current range of 0.0143 - 0.0592 mA. The best sensitivity is produced in EPKZLP with a value of 0.031 mAcm-2mM-1. The best stability was found in EPKZLP with a percentage of stability on day 14 was 30.9%. The average standard deviation generated in this study is 0.0024 mA with a relative error value was 7.8%. Addition of zeolite to biosensor material produced in this study has met several criteria to be used as a sensor. Keywords: uric acid biosensor, zeolite, sodalit, sensitivity, stability.https://journal.unj.ac.id/unj/index.php/spektra/article/view/8648uric acid biosensor, zeolite, sodalit, sensitivity, stability
spellingShingle Iza Faizah
Dwi Puryanti
Afdhal Muttaqin
THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHOD
Spektra: Jurnal Fisika dan Aplikasinya
uric acid biosensor, zeolite, sodalit, sensitivity, stability
title THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHOD
title_full THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHOD
title_fullStr THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHOD
title_full_unstemmed THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHOD
title_short THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHOD
title_sort effect of synthetic zeolites on sensitivity and stability of uric acid biosensor using cycle voltametry method
topic uric acid biosensor, zeolite, sodalit, sensitivity, stability
url https://journal.unj.ac.id/unj/index.php/spektra/article/view/8648
work_keys_str_mv AT izafaizah theeffectofsyntheticzeolitesonsensitivityandstabilityofuricacidbiosensorusingcyclevoltametrymethod
AT dwipuryanti theeffectofsyntheticzeolitesonsensitivityandstabilityofuricacidbiosensorusingcyclevoltametrymethod
AT afdhalmuttaqin theeffectofsyntheticzeolitesonsensitivityandstabilityofuricacidbiosensorusingcyclevoltametrymethod
AT izafaizah effectofsyntheticzeolitesonsensitivityandstabilityofuricacidbiosensorusingcyclevoltametrymethod
AT dwipuryanti effectofsyntheticzeolitesonsensitivityandstabilityofuricacidbiosensorusingcyclevoltametrymethod
AT afdhalmuttaqin effectofsyntheticzeolitesonsensitivityandstabilityofuricacidbiosensorusingcyclevoltametrymethod