Fault Location Method for Communication Link with Multi-information Fusion Modeling of Smart Substation

In order to solve such problems of smart substations as numerous alarm information caused by communication link failure and poor operation efficiency, a fault location method for communication link is proposed with multi-information fusion modeling of smart substation. Firstly, a communication netwo...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhiyong PI, Yi ZHU, Xuan LIAO, Zhenxing LI, Hao FANG, Pei WU
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2023-08-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202212075
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850070119992000512
author Zhiyong PI
Yi ZHU
Xuan LIAO
Zhenxing LI
Hao FANG
Pei WU
author_facet Zhiyong PI
Yi ZHU
Xuan LIAO
Zhenxing LI
Hao FANG
Pei WU
author_sort Zhiyong PI
collection DOAJ
description In order to solve such problems of smart substations as numerous alarm information caused by communication link failure and poor operation efficiency, a fault location method for communication link is proposed with multi-information fusion modeling of smart substation. Firstly, a communication network numbering principle is proposed by traversing the device nodes of SCD. Secondly, by fusing multiple alarm information, the node and link coding rules are formulated, and the node-link mapping relationship and positioning model are established. And then, the adaptive genetic particle swarm algorithm is used to solve the positioning model to achieve accurate positioning of link faults. Finally, taking the secondary network of a 220 kV smart substation as an example, the effectiveness of the proposed method is verified under different link failure scenarios.
format Article
id doaj-art-d4c75dd7b26d41bf8010856f083dbf9c
institution DOAJ
issn 1004-9649
language zho
publishDate 2023-08-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-d4c75dd7b26d41bf8010856f083dbf9c2025-08-20T02:47:37ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492023-08-0156820721510.11930/j.issn.1004-9649.202212075zgdl-56-8-pizhiyongFault Location Method for Communication Link with Multi-information Fusion Modeling of Smart SubstationZhiyong PI0Yi ZHU1Xuan LIAO2Zhenxing LI3Hao FANG4Pei WU5State Grid Hubei Jingmen Electric Power Supply Company, Jingmen 448000, ChinaCollege of Electrical Engineering and New Energy, Three Gorges University, Yichang 443002, ChinaState Grid Hubei Jingmen Electric Power Supply Company, Jingmen 448000, ChinaCollege of Electrical Engineering and New Energy, Three Gorges University, Yichang 443002, ChinaCollege of Electrical Engineering and New Energy, Three Gorges University, Yichang 443002, ChinaState Grid Hubei Jingmen Electric Power Supply Company, Jingmen 448000, ChinaIn order to solve such problems of smart substations as numerous alarm information caused by communication link failure and poor operation efficiency, a fault location method for communication link is proposed with multi-information fusion modeling of smart substation. Firstly, a communication network numbering principle is proposed by traversing the device nodes of SCD. Secondly, by fusing multiple alarm information, the node and link coding rules are formulated, and the node-link mapping relationship and positioning model are established. And then, the adaptive genetic particle swarm algorithm is used to solve the positioning model to achieve accurate positioning of link faults. Finally, taking the secondary network of a 220 kV smart substation as an example, the effectiveness of the proposed method is verified under different link failure scenarios.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202212075smart substationlink fault locationalarm informationexpected mappingadaptive genetic particle swarm optimization
spellingShingle Zhiyong PI
Yi ZHU
Xuan LIAO
Zhenxing LI
Hao FANG
Pei WU
Fault Location Method for Communication Link with Multi-information Fusion Modeling of Smart Substation
Zhongguo dianli
smart substation
link fault location
alarm information
expected mapping
adaptive genetic particle swarm optimization
title Fault Location Method for Communication Link with Multi-information Fusion Modeling of Smart Substation
title_full Fault Location Method for Communication Link with Multi-information Fusion Modeling of Smart Substation
title_fullStr Fault Location Method for Communication Link with Multi-information Fusion Modeling of Smart Substation
title_full_unstemmed Fault Location Method for Communication Link with Multi-information Fusion Modeling of Smart Substation
title_short Fault Location Method for Communication Link with Multi-information Fusion Modeling of Smart Substation
title_sort fault location method for communication link with multi information fusion modeling of smart substation
topic smart substation
link fault location
alarm information
expected mapping
adaptive genetic particle swarm optimization
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202212075
work_keys_str_mv AT zhiyongpi faultlocationmethodforcommunicationlinkwithmultiinformationfusionmodelingofsmartsubstation
AT yizhu faultlocationmethodforcommunicationlinkwithmultiinformationfusionmodelingofsmartsubstation
AT xuanliao faultlocationmethodforcommunicationlinkwithmultiinformationfusionmodelingofsmartsubstation
AT zhenxingli faultlocationmethodforcommunicationlinkwithmultiinformationfusionmodelingofsmartsubstation
AT haofang faultlocationmethodforcommunicationlinkwithmultiinformationfusionmodelingofsmartsubstation
AT peiwu faultlocationmethodforcommunicationlinkwithmultiinformationfusionmodelingofsmartsubstation