Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults

We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I–IV) were randomly allocated to receive the...

Full description

Saved in:
Bibliographic Details
Main Authors: Daryl Lindsay Williams, James M. Zeng, Karl D. Alexander, David T. Andrews
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Anesthesiology Research and Practice
Online Access:http://dx.doi.org/10.1155/2012/405812
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832550658688942080
author Daryl Lindsay Williams
James M. Zeng
Karl D. Alexander
David T. Andrews
author_facet Daryl Lindsay Williams
James M. Zeng
Karl D. Alexander
David T. Andrews
author_sort Daryl Lindsay Williams
collection DOAJ
description We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I–IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic and all airway devices were inserted by trained anaesthetists. Size selection was guided by manufacturer recommendations. All data were collected by a single, unblinded observer. When compared with the LMAU, the AMBU produced significantly higher airway sealing pressures (AMBU 20±6; LMAU 15±7 cm H2O; P=0.001). There was no statistical difference between the two devices for overall success rate, insertion time, number of adjustments, laryngeal alignment, blood-staining, and sore throat (P≥0.05). The AMBU AuraOnce disposable laryngeal mask provided a higher oropharyngeal leak pressure compared to the LMA Unique in spontaneously breathing adult patients.
format Article
id doaj-art-d4683a877c4a4ec99db03caf0ac525f0
institution Kabale University
issn 1687-6962
1687-6970
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series Anesthesiology Research and Practice
spelling doaj-art-d4683a877c4a4ec99db03caf0ac525f02025-02-03T06:06:18ZengWileyAnesthesiology Research and Practice1687-69621687-69702012-01-01201210.1155/2012/405812405812Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing AdultsDaryl Lindsay Williams0James M. Zeng1Karl D. Alexander2David T. Andrews3Department of Anaesthesia and Pain Management, Royal Melbourne Hospital, Parkville 3050, AustraliaDepartment of Anaesthesia and Pain Management, Royal Melbourne Hospital, Parkville 3050, AustraliaDepartment of Anaesthesia and Pain Management, Royal Melbourne Hospital, Parkville 3050, AustraliaDepartment of Anaesthesia and Pain Management, Royal Melbourne Hospital, Parkville 3050, AustraliaWe conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I–IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic and all airway devices were inserted by trained anaesthetists. Size selection was guided by manufacturer recommendations. All data were collected by a single, unblinded observer. When compared with the LMAU, the AMBU produced significantly higher airway sealing pressures (AMBU 20±6; LMAU 15±7 cm H2O; P=0.001). There was no statistical difference between the two devices for overall success rate, insertion time, number of adjustments, laryngeal alignment, blood-staining, and sore throat (P≥0.05). The AMBU AuraOnce disposable laryngeal mask provided a higher oropharyngeal leak pressure compared to the LMA Unique in spontaneously breathing adult patients.http://dx.doi.org/10.1155/2012/405812
spellingShingle Daryl Lindsay Williams
James M. Zeng
Karl D. Alexander
David T. Andrews
Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
Anesthesiology Research and Practice
title Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
title_full Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
title_fullStr Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
title_full_unstemmed Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
title_short Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
title_sort randomised comparison of the ambu auraonce laryngeal mask and the lma unique laryngeal mask airway in spontaneously breathing adults
url http://dx.doi.org/10.1155/2012/405812
work_keys_str_mv AT daryllindsaywilliams randomisedcomparisonoftheambuauraoncelaryngealmaskandthelmauniquelaryngealmaskairwayinspontaneouslybreathingadults
AT jamesmzeng randomisedcomparisonoftheambuauraoncelaryngealmaskandthelmauniquelaryngealmaskairwayinspontaneouslybreathingadults
AT karldalexander randomisedcomparisonoftheambuauraoncelaryngealmaskandthelmauniquelaryngealmaskairwayinspontaneouslybreathingadults
AT davidtandrews randomisedcomparisonoftheambuauraoncelaryngealmaskandthelmauniquelaryngealmaskairwayinspontaneouslybreathingadults