Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray Practices

Purpose Radiographic examinations are frequently performed for diagnostic and therapeutic purposes in neonatal intensive care units (NICUs). However, concerns are emerging regarding the safety of radiation exposure, especially in vulnerable preterm infants in periods of rapid cellular division. This...

Full description

Saved in:
Bibliographic Details
Main Authors: Jae Hui Ryu, Seung Han Shin, Young Hun Choi, Ee-Kyung Kim, Han-Suk Kim
Format: Article
Language:English
Published: Korean Society of Neonatology 2024-11-01
Series:Neonatal Medicine
Subjects:
Online Access:http://www.neo-med.org/upload/pdf/nm-2024-31-3-56.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850163866021920768
author Jae Hui Ryu
Seung Han Shin
Young Hun Choi
Ee-Kyung Kim
Han-Suk Kim
author_facet Jae Hui Ryu
Seung Han Shin
Young Hun Choi
Ee-Kyung Kim
Han-Suk Kim
author_sort Jae Hui Ryu
collection DOAJ
description Purpose Radiographic examinations are frequently performed for diagnostic and therapeutic purposes in neonatal intensive care units (NICUs). However, concerns are emerging regarding the safety of radiation exposure, especially in vulnerable preterm infants in periods of rapid cellular division. This quality improvement (QI) project aimed to reduce radiation hazards in level-IV NICU. Methods We established an "X-ray prescription protocol" and educated the physicians to ensure that only essential radiographs were obtained. Additionally, we discouraged full-body infantograms and emphasized the prescription of targeted radiographs, such as chest or abdominal radiographs. Furthermore, to reduce the dose-area product (DAP, Gy·cm2) values, which act as a surrogate for radiation exposure, we provided training to radiologic technologists on meticulous collimation for each radiography session. We aimed to achieve a 30% reduction in the average monthly cumulative DAP per patient, which was calculated by dividing the total monthly DAP from radiographs in the NICU by the monthly average of patient admissions. Retrospective baseline data were collected 8 months pre-intervention and prospectively for 4 months post-interventions. Results The average monthly X-ray count per patient was 28.3 in the pre-intervention period (October 2022 to May 2023), which decreased to 25.4 in the post-intervention period (June 2023 to September 2023), reflecting a 10.2% reduction (p=0.109). The average monthly infantogram count per patient showed an 18.0% reduction (25.9% to 21.2%, p=0.016), and the proportion of infantograms in the total X-ray counts decreased from 91.5% to 83.3% (p=0.017). The DAP value per X-ray decreased by 42.6%, from an average of 0.25 to 0.14 (p=0.011). The primary outcome, the average monthly cumulative DAP value per patient, showed a substantial reduction of 48.6%, dropping from 7.00 to 3.60 (p=0.004). The baseline characteristics and short-term morbidities of the patients did not differ significantly between the pre- and post-intervention period. Conclusion Our QI approach, which included discouraging excessive prescriptions of infantograms and promoting optimal collimation, significantly reduced the average monthly radiation exposure in the NICU, benefiting both patients and healthcare workers.
format Article
id doaj-art-d4419d8d5ca84de7a0e45da3ea90ae1d
institution OA Journals
issn 2287-9412
2287-9803
language English
publishDate 2024-11-01
publisher Korean Society of Neonatology
record_format Article
series Neonatal Medicine
spelling doaj-art-d4419d8d5ca84de7a0e45da3ea90ae1d2025-08-20T02:22:06ZengKorean Society of NeonatologyNeonatal Medicine2287-94122287-98032024-11-01313566410.5385/nm.2024.31.3.561100Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray PracticesJae Hui Ryu0Seung Han Shin1Young Hun Choi2Ee-Kyung Kim3Han-Suk Kim4 Department of Pediatrics, Ewha Womans University Mokdong Hospital, Ewha Womans University College of Medicine, Seoul, Korea Department of Pediatrics, Seoul National University Children’s Hospital, Seoul National University College of Medicine, Seoul, Korea Department of Radiology, Seoul National University Children’s Hospital, Seoul National University College of Medicine, Seoul, Korea Department of Pediatrics, Seoul National University Children’s Hospital, Seoul National University College of Medicine, Seoul, Korea Department of Pediatrics, Seoul National University Children’s Hospital, Seoul National University College of Medicine, Seoul, KoreaPurpose Radiographic examinations are frequently performed for diagnostic and therapeutic purposes in neonatal intensive care units (NICUs). However, concerns are emerging regarding the safety of radiation exposure, especially in vulnerable preterm infants in periods of rapid cellular division. This quality improvement (QI) project aimed to reduce radiation hazards in level-IV NICU. Methods We established an "X-ray prescription protocol" and educated the physicians to ensure that only essential radiographs were obtained. Additionally, we discouraged full-body infantograms and emphasized the prescription of targeted radiographs, such as chest or abdominal radiographs. Furthermore, to reduce the dose-area product (DAP, Gy·cm2) values, which act as a surrogate for radiation exposure, we provided training to radiologic technologists on meticulous collimation for each radiography session. We aimed to achieve a 30% reduction in the average monthly cumulative DAP per patient, which was calculated by dividing the total monthly DAP from radiographs in the NICU by the monthly average of patient admissions. Retrospective baseline data were collected 8 months pre-intervention and prospectively for 4 months post-interventions. Results The average monthly X-ray count per patient was 28.3 in the pre-intervention period (October 2022 to May 2023), which decreased to 25.4 in the post-intervention period (June 2023 to September 2023), reflecting a 10.2% reduction (p=0.109). The average monthly infantogram count per patient showed an 18.0% reduction (25.9% to 21.2%, p=0.016), and the proportion of infantograms in the total X-ray counts decreased from 91.5% to 83.3% (p=0.017). The DAP value per X-ray decreased by 42.6%, from an average of 0.25 to 0.14 (p=0.011). The primary outcome, the average monthly cumulative DAP value per patient, showed a substantial reduction of 48.6%, dropping from 7.00 to 3.60 (p=0.004). The baseline characteristics and short-term morbidities of the patients did not differ significantly between the pre- and post-intervention period. Conclusion Our QI approach, which included discouraging excessive prescriptions of infantograms and promoting optimal collimation, significantly reduced the average monthly radiation exposure in the NICU, benefiting both patients and healthcare workers.http://www.neo-med.org/upload/pdf/nm-2024-31-3-56.pdfradiationinfantogramx-raysdose area productprematurity
spellingShingle Jae Hui Ryu
Seung Han Shin
Young Hun Choi
Ee-Kyung Kim
Han-Suk Kim
Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray Practices
Neonatal Medicine
radiation
infantogram
x-rays
dose area product
prematurity
title Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray Practices
title_full Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray Practices
title_fullStr Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray Practices
title_full_unstemmed Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray Practices
title_short Minimizing Radiation Exposure in Neonatal Intensive Care Unit: A Quality Improvement Approach on X-Ray Practices
title_sort minimizing radiation exposure in neonatal intensive care unit a quality improvement approach on x ray practices
topic radiation
infantogram
x-rays
dose area product
prematurity
url http://www.neo-med.org/upload/pdf/nm-2024-31-3-56.pdf
work_keys_str_mv AT jaehuiryu minimizingradiationexposureinneonatalintensivecareunitaqualityimprovementapproachonxraypractices
AT seunghanshin minimizingradiationexposureinneonatalintensivecareunitaqualityimprovementapproachonxraypractices
AT younghunchoi minimizingradiationexposureinneonatalintensivecareunitaqualityimprovementapproachonxraypractices
AT eekyungkim minimizingradiationexposureinneonatalintensivecareunitaqualityimprovementapproachonxraypractices
AT hansukkim minimizingradiationexposureinneonatalintensivecareunitaqualityimprovementapproachonxraypractices