Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemMendeley Data

A thermal analysis of a thermoelectric radiant panel (TERP) system was conducted to evaluate its cooling effectiveness in maintaining indoor comfort within the temperature range recommended by ASHRAE Standard 55 and Malaysian Standard (MS) 1525 under tropical climate conditions. The study utilized A...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhammad ‘Amir Roslan, Farah Liana Mohd Redzuan
Format: Article
Language:English
Published: Elsevier 2025-06-01
Series:Data in Brief
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352340925002793
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849470665324756992
author Muhammad ‘Amir Roslan
Farah Liana Mohd Redzuan
author_facet Muhammad ‘Amir Roslan
Farah Liana Mohd Redzuan
author_sort Muhammad ‘Amir Roslan
collection DOAJ
description A thermal analysis of a thermoelectric radiant panel (TERP) system was conducted to evaluate its cooling effectiveness in maintaining indoor comfort within the temperature range recommended by ASHRAE Standard 55 and Malaysian Standard (MS) 1525 under tropical climate conditions. The study utilized ANSYS software, incorporating computational fluid dynamics (CFD) tools for detailed heat transfer simulations. The analysis examined the impact of outdoor temperature variations on indoor conditions and TERP system panel temperatures by considering heat transfer mechanisms, boundary conditions, and material properties to ensure accuracy. By accounting for these factors, the simulation provided a realistic representation of the thermal environment in a tropical climate. The simulation results were visualized as 3D thermal profiles, with color contours illustrating temperature distributions across the panel surface and the indoor environment. The collected data was then simplified into graph form for easier interpretation and analysis, including an evaluation of compliance with thermal comfort standards such as ASHRAE Standard 55 and MS 1525. The findings serve as a benchmark for assessing thermoelectric cooling performance in tropical buildings and offer valuable insights for optimizing thermoelectric cooling systems in similar climates. This study contributes to the development of sustainable cooling solutions and supports further research in thermoelectric cooling applications.
format Article
id doaj-art-d364f0edbefd4b40868aee76eb9a450e
institution Kabale University
issn 2352-3409
language English
publishDate 2025-06-01
publisher Elsevier
record_format Article
series Data in Brief
spelling doaj-art-d364f0edbefd4b40868aee76eb9a450e2025-08-20T03:25:05ZengElsevierData in Brief2352-34092025-06-016011154710.1016/j.dib.2025.111547Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemMendeley DataMuhammad ‘Amir Roslan0Farah Liana Mohd Redzuan1Malaysia-Japan International Institute of Technology, University of Technology Malaysia (UTM), Kuala Lumpur, MalaysiaCorresponding author.; Malaysia-Japan International Institute of Technology, University of Technology Malaysia (UTM), Kuala Lumpur, MalaysiaA thermal analysis of a thermoelectric radiant panel (TERP) system was conducted to evaluate its cooling effectiveness in maintaining indoor comfort within the temperature range recommended by ASHRAE Standard 55 and Malaysian Standard (MS) 1525 under tropical climate conditions. The study utilized ANSYS software, incorporating computational fluid dynamics (CFD) tools for detailed heat transfer simulations. The analysis examined the impact of outdoor temperature variations on indoor conditions and TERP system panel temperatures by considering heat transfer mechanisms, boundary conditions, and material properties to ensure accuracy. By accounting for these factors, the simulation provided a realistic representation of the thermal environment in a tropical climate. The simulation results were visualized as 3D thermal profiles, with color contours illustrating temperature distributions across the panel surface and the indoor environment. The collected data was then simplified into graph form for easier interpretation and analysis, including an evaluation of compliance with thermal comfort standards such as ASHRAE Standard 55 and MS 1525. The findings serve as a benchmark for assessing thermoelectric cooling performance in tropical buildings and offer valuable insights for optimizing thermoelectric cooling systems in similar climates. This study contributes to the development of sustainable cooling solutions and supports further research in thermoelectric cooling applications.http://www.sciencedirect.com/science/article/pii/S2352340925002793Thermal analysisTERP systemCooling effectivenessThermal comfortTropical climateCFD
spellingShingle Muhammad ‘Amir Roslan
Farah Liana Mohd Redzuan
Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemMendeley Data
Data in Brief
Thermal analysis
TERP system
Cooling effectiveness
Thermal comfort
Tropical climate
CFD
title Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemMendeley Data
title_full Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemMendeley Data
title_fullStr Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemMendeley Data
title_full_unstemmed Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemMendeley Data
title_short Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemMendeley Data
title_sort data driven thermal analysis of indoor cooling for a thermoelectric radiant panel systemmendeley data
topic Thermal analysis
TERP system
Cooling effectiveness
Thermal comfort
Tropical climate
CFD
url http://www.sciencedirect.com/science/article/pii/S2352340925002793
work_keys_str_mv AT muhammadamirroslan datadriventhermalanalysisofindoorcoolingforathermoelectricradiantpanelsystemmendeleydata
AT farahlianamohdredzuan datadriventhermalanalysisofindoorcoolingforathermoelectricradiantpanelsystemmendeleydata