REAL TIME ASSESSMENT OF 500-KVA, 11/0.415 KV DISTRIBUTION TRANSFORMER SITUATED AT BELLS UNIVERSITY OF TECHNOLOGY, OTA, OGUN STATE USING FLUKE 435 SERIES II
Distribution transformer being major equipment in utility companies deserves to be routinely scrutinized for its performance with a view to ensure continuous supply of energy to end-users as well as to sustain improved revenue collection by the utility company. Presented in this paper is the real t...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Alma Mater Publishing House "Vasile Alecsandri" University of Bacau
2020-06-01
|
Series: | Journal of Engineering Studies and Research |
Subjects: | |
Online Access: | https://jesr.ub.ro/index.php/1/article/view/164 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1823863637720170496 |
---|---|
author | ABRAHAM OLATIDE AMOLE KAZIM IDOWU OKUSAGA OLUFEMI OLANREWAJU ODEKUNLE IKECHUKWU JOSEPH ODITA |
author_facet | ABRAHAM OLATIDE AMOLE KAZIM IDOWU OKUSAGA OLUFEMI OLANREWAJU ODEKUNLE IKECHUKWU JOSEPH ODITA |
author_sort | ABRAHAM OLATIDE AMOLE |
collection | DOAJ |
description |
Distribution transformer being major equipment in utility companies deserves to be routinely scrutinized for its performance with a view to ensure continuous supply of energy to end-users as well as to sustain improved revenue collection by the utility company. Presented in this paper is the real time assessment of 500-kVA, 11/0.415 kV distribution transformer situated at Bells University of Technology, Ota, Ogun State using power quality and energy analyzer equipment. The parameters measured on real time include phase to neutral voltage, phase to phase voltage, root mean square and peak current, frequency, active power, reactive and apparent power and line power factor. The assessment revealed wide variation of system voltages far from the standard, however, the line power factor and as well as frequency of operation was observed to be within the standard. Based on this analysis, several findings and appropriate recommendations were suggested to improve the supply of energy in the study area. It is hope that the findings of this research will be of immense benefit to distribution engineers at the Department of works in Bells University of Technology, Ota for field compliance.
|
format | Article |
id | doaj-art-d2cd075189b94aaf8e905c1e4bf365ce |
institution | Kabale University |
issn | 2068-7559 2344-4932 |
language | English |
publishDate | 2020-06-01 |
publisher | Alma Mater Publishing House "Vasile Alecsandri" University of Bacau |
record_format | Article |
series | Journal of Engineering Studies and Research |
spelling | doaj-art-d2cd075189b94aaf8e905c1e4bf365ce2025-02-09T11:37:40ZengAlma Mater Publishing House "Vasile Alecsandri" University of BacauJournal of Engineering Studies and Research2068-75592344-49322020-06-01262REAL TIME ASSESSMENT OF 500-KVA, 11/0.415 KV DISTRIBUTION TRANSFORMER SITUATED AT BELLS UNIVERSITY OF TECHNOLOGY, OTA, OGUN STATE USING FLUKE 435 SERIES IIABRAHAM OLATIDE AMOLE KAZIM IDOWU OKUSAGA OLUFEMI OLANREWAJU ODEKUNLE IKECHUKWU JOSEPH ODITA Distribution transformer being major equipment in utility companies deserves to be routinely scrutinized for its performance with a view to ensure continuous supply of energy to end-users as well as to sustain improved revenue collection by the utility company. Presented in this paper is the real time assessment of 500-kVA, 11/0.415 kV distribution transformer situated at Bells University of Technology, Ota, Ogun State using power quality and energy analyzer equipment. The parameters measured on real time include phase to neutral voltage, phase to phase voltage, root mean square and peak current, frequency, active power, reactive and apparent power and line power factor. The assessment revealed wide variation of system voltages far from the standard, however, the line power factor and as well as frequency of operation was observed to be within the standard. Based on this analysis, several findings and appropriate recommendations were suggested to improve the supply of energy in the study area. It is hope that the findings of this research will be of immense benefit to distribution engineers at the Department of works in Bells University of Technology, Ota for field compliance. https://jesr.ub.ro/index.php/1/article/view/164apparent power, distribution transformer, power factor, reactive power, real power |
spellingShingle | ABRAHAM OLATIDE AMOLE KAZIM IDOWU OKUSAGA OLUFEMI OLANREWAJU ODEKUNLE IKECHUKWU JOSEPH ODITA REAL TIME ASSESSMENT OF 500-KVA, 11/0.415 KV DISTRIBUTION TRANSFORMER SITUATED AT BELLS UNIVERSITY OF TECHNOLOGY, OTA, OGUN STATE USING FLUKE 435 SERIES II Journal of Engineering Studies and Research apparent power, distribution transformer, power factor, reactive power, real power |
title | REAL TIME ASSESSMENT OF 500-KVA, 11/0.415 KV DISTRIBUTION TRANSFORMER SITUATED AT BELLS UNIVERSITY OF TECHNOLOGY, OTA, OGUN STATE USING FLUKE 435 SERIES II |
title_full | REAL TIME ASSESSMENT OF 500-KVA, 11/0.415 KV DISTRIBUTION TRANSFORMER SITUATED AT BELLS UNIVERSITY OF TECHNOLOGY, OTA, OGUN STATE USING FLUKE 435 SERIES II |
title_fullStr | REAL TIME ASSESSMENT OF 500-KVA, 11/0.415 KV DISTRIBUTION TRANSFORMER SITUATED AT BELLS UNIVERSITY OF TECHNOLOGY, OTA, OGUN STATE USING FLUKE 435 SERIES II |
title_full_unstemmed | REAL TIME ASSESSMENT OF 500-KVA, 11/0.415 KV DISTRIBUTION TRANSFORMER SITUATED AT BELLS UNIVERSITY OF TECHNOLOGY, OTA, OGUN STATE USING FLUKE 435 SERIES II |
title_short | REAL TIME ASSESSMENT OF 500-KVA, 11/0.415 KV DISTRIBUTION TRANSFORMER SITUATED AT BELLS UNIVERSITY OF TECHNOLOGY, OTA, OGUN STATE USING FLUKE 435 SERIES II |
title_sort | real time assessment of 500 kva 11 0 415 kv distribution transformer situated at bells university of technology ota ogun state using fluke 435 series ii |
topic | apparent power, distribution transformer, power factor, reactive power, real power |
url | https://jesr.ub.ro/index.php/1/article/view/164 |
work_keys_str_mv | AT abrahamolatideamole realtimeassessmentof500kva110415kvdistributiontransformersituatedatbellsuniversityoftechnologyotaogunstateusingfluke435seriesii AT kazimidowuokusaga realtimeassessmentof500kva110415kvdistributiontransformersituatedatbellsuniversityoftechnologyotaogunstateusingfluke435seriesii AT olufemiolanrewajuodekunle realtimeassessmentof500kva110415kvdistributiontransformersituatedatbellsuniversityoftechnologyotaogunstateusingfluke435seriesii AT ikechukwujosephodita realtimeassessmentof500kva110415kvdistributiontransformersituatedatbellsuniversityoftechnologyotaogunstateusingfluke435seriesii |