Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems

This study investigates the efficiency evaluation of a compressor rotor designed for drive units requiring compressors with a power demand of less than 30 kW. The primary aim of the research presented in this article is to assess the feasibility of utilizing axial compressors to maintain high effici...

Full description

Saved in:
Bibliographic Details
Main Authors: Natalia Kapela, Karolina Wyżkiewicz, Andrzej Frąckowiak
Format: Article
Language:English
Published: MDPI AG 2024-12-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/18/1/123
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841549232443490304
author Natalia Kapela
Karolina Wyżkiewicz
Andrzej Frąckowiak
author_facet Natalia Kapela
Karolina Wyżkiewicz
Andrzej Frąckowiak
author_sort Natalia Kapela
collection DOAJ
description This study investigates the efficiency evaluation of a compressor rotor designed for drive units requiring compressors with a power demand of less than 30 kW. The primary aim of the research presented in this article is to assess the feasibility of utilizing axial compressors to maintain high efficiency across a broad range of rotor speeds. A critical challenge in the considered power range is the occurrence of low Reynolds numbers, specifically those below 250,000. This research seeks to identify the underlying causes of efficiency degradation at low Reynolds numbers and determine the rotor’s geometric parameters which most significantly influence the localized efficiency drop. Compressor efficiency was evaluated through numerical simulations. The numerical model was validated using experimental data and subjected to a grid independence study. Simulations were conducted for nine geometric configurations of the axial compressor rotor, with modifications to parameters such as the blade angle, blade thickness, blade solidity, and hub-to-tip ratio. For each configuration, a series of simulations was performed at rotor speeds ranging from 400 RPM to 2400 RPM. The simulation results indicated that the blade angle solidity was the most influential parameter affecting efficiency. A reduction in the blade angle led to approximately a 20% decrease in efficiency, primarily due to localized flow separation near the blade tip. Additionally, altering the number of blades caused a 20% efficiency reduction attributed to hub corner separation. The findings enabled the identification of optimal parameters, which will serve as a foundation for efficiency testing in the multistage configuration.
format Article
id doaj-art-d26c74bb164d4211967445e91b7bef1a
institution Kabale University
issn 1996-1073
language English
publishDate 2024-12-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj-art-d26c74bb164d4211967445e91b7bef1a2025-01-10T13:17:10ZengMDPI AGEnergies1996-10732024-12-0118112310.3390/en18010123Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive SystemsNatalia Kapela0Karolina Wyżkiewicz1Andrzej Frąckowiak2Institute of Thermal Engineering, Poznan University of Technology, 60-965 Poznan, PolandInstitute of Thermal Engineering, Poznan University of Technology, 60-965 Poznan, PolandInstitute of Thermal Engineering, Poznan University of Technology, 60-965 Poznan, PolandThis study investigates the efficiency evaluation of a compressor rotor designed for drive units requiring compressors with a power demand of less than 30 kW. The primary aim of the research presented in this article is to assess the feasibility of utilizing axial compressors to maintain high efficiency across a broad range of rotor speeds. A critical challenge in the considered power range is the occurrence of low Reynolds numbers, specifically those below 250,000. This research seeks to identify the underlying causes of efficiency degradation at low Reynolds numbers and determine the rotor’s geometric parameters which most significantly influence the localized efficiency drop. Compressor efficiency was evaluated through numerical simulations. The numerical model was validated using experimental data and subjected to a grid independence study. Simulations were conducted for nine geometric configurations of the axial compressor rotor, with modifications to parameters such as the blade angle, blade thickness, blade solidity, and hub-to-tip ratio. For each configuration, a series of simulations was performed at rotor speeds ranging from 400 RPM to 2400 RPM. The simulation results indicated that the blade angle solidity was the most influential parameter affecting efficiency. A reduction in the blade angle led to approximately a 20% decrease in efficiency, primarily due to localized flow separation near the blade tip. Additionally, altering the number of blades caused a 20% efficiency reduction attributed to hub corner separation. The findings enabled the identification of optimal parameters, which will serve as a foundation for efficiency testing in the multistage configuration.https://www.mdpi.com/1996-1073/18/1/123turbomachineryaxial compressorReynolds number
spellingShingle Natalia Kapela
Karolina Wyżkiewicz
Andrzej Frąckowiak
Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems
Energies
turbomachinery
axial compressor
Reynolds number
title Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems
title_full Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems
title_fullStr Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems
title_full_unstemmed Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems
title_short Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems
title_sort performance analysis of a compressor rotor dedicated to low power drive systems
topic turbomachinery
axial compressor
Reynolds number
url https://www.mdpi.com/1996-1073/18/1/123
work_keys_str_mv AT nataliakapela performanceanalysisofacompressorrotordedicatedtolowpowerdrivesystems
AT karolinawyzkiewicz performanceanalysisofacompressorrotordedicatedtolowpowerdrivesystems
AT andrzejfrackowiak performanceanalysisofacompressorrotordedicatedtolowpowerdrivesystems