Is “Bite force” a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?

Objectives: Mandible is an integral part of masticatory system, and it is expected that it’s fracture will have a significant impact on occlusal forces, range of motion, muscle activity levels, and occlusion. The main objective of this study was to compare the efficacy of 3-dimensional (3D) miniplat...

Full description

Saved in:
Bibliographic Details
Main Authors: Shital Patel, Kruna Bhimani, Roma Narsingyani, Zenish Bhatti, Rajan Savani
Format: Article
Language:English
Published: Elsevier 2022-11-01
Series:Journal of Oral Biology and Craniofacial Research
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2212426822001257
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850060775265140736
author Shital Patel
Kruna Bhimani
Roma Narsingyani
Zenish Bhatti
Rajan Savani
author_facet Shital Patel
Kruna Bhimani
Roma Narsingyani
Zenish Bhatti
Rajan Savani
author_sort Shital Patel
collection DOAJ
description Objectives: Mandible is an integral part of masticatory system, and it is expected that it’s fracture will have a significant impact on occlusal forces, range of motion, muscle activity levels, and occlusion. The main objective of this study was to compare the efficacy of 3-dimensional (3D) miniplate and conventional miniplates for fixation of anterior mandibular fractures on the basis of bite force as a main parameter. Methods: 66 patients having isolated anterior mandibular fractures were randomized into two groups equally: Conventional miniplates and 3D miniplates. The bite force at incisor, canine, and molar regions was measured preoperatively and postoperatively at weekly intervals until the sixth week, and the mean bite force as well as changes in mean bite force were compared between two groups. Results: An increase in bite force was noted at each subsequent follow up in both the groups across all sites. Statistically significant difference was found in mean bite force values between both the groups during mid-follow up period. The difference in changes in the mean bite force too was observed to be statistically significant during the mid to late follow up period. Interpretation & conclusion: Bite force is a reliable parameter to assess restoration of masticatory efficiency following open reduction and internal fixation (ORIF). 3D miniplates when used in anterior mandibular fractures management are efficient enough to withstand masticatory forces throughout the healing process, providing better stability of fractured segments against torsional forces during immediate post-operative period.
format Article
id doaj-art-d1d5c1d6578446fcb24610fc20c9efdf
institution DOAJ
issn 2212-4268
language English
publishDate 2022-11-01
publisher Elsevier
record_format Article
series Journal of Oral Biology and Craniofacial Research
spelling doaj-art-d1d5c1d6578446fcb24610fc20c9efdf2025-08-20T02:50:27ZengElsevierJournal of Oral Biology and Craniofacial Research2212-42682022-11-0112677778110.1016/j.jobcr.2022.09.004Is “Bite force” a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?Shital Patel0Kruna Bhimani1Roma Narsingyani2Zenish Bhatti3Rajan Savani4Department of Oral and Maxillofacial Surgery, Ahmedabad Municipal Corporation Dental College and Hospital, Ahmedabad, IndiaCorresponding author. 306, Candle Madhav co.op.hsg.soc.ltd, Near-Golden Point, GIDC, Ankleshwar, 393002, India.; Department of Oral and Maxillofacial Surgery, Ahmedabad Municipal Corporation Dental College and Hospital, Ahmedabad, IndiaDepartment of Oral and Maxillofacial Surgery, Ahmedabad Municipal Corporation Dental College and Hospital, Ahmedabad, IndiaDepartment of Oral and Maxillofacial Surgery, Ahmedabad Municipal Corporation Dental College and Hospital, Ahmedabad, IndiaDepartment of Oral and Maxillofacial Surgery, Ahmedabad Municipal Corporation Dental College and Hospital, Ahmedabad, IndiaObjectives: Mandible is an integral part of masticatory system, and it is expected that it’s fracture will have a significant impact on occlusal forces, range of motion, muscle activity levels, and occlusion. The main objective of this study was to compare the efficacy of 3-dimensional (3D) miniplate and conventional miniplates for fixation of anterior mandibular fractures on the basis of bite force as a main parameter. Methods: 66 patients having isolated anterior mandibular fractures were randomized into two groups equally: Conventional miniplates and 3D miniplates. The bite force at incisor, canine, and molar regions was measured preoperatively and postoperatively at weekly intervals until the sixth week, and the mean bite force as well as changes in mean bite force were compared between two groups. Results: An increase in bite force was noted at each subsequent follow up in both the groups across all sites. Statistically significant difference was found in mean bite force values between both the groups during mid-follow up period. The difference in changes in the mean bite force too was observed to be statistically significant during the mid to late follow up period. Interpretation & conclusion: Bite force is a reliable parameter to assess restoration of masticatory efficiency following open reduction and internal fixation (ORIF). 3D miniplates when used in anterior mandibular fractures management are efficient enough to withstand masticatory forces throughout the healing process, providing better stability of fractured segments against torsional forces during immediate post-operative period.http://www.sciencedirect.com/science/article/pii/S2212426822001257Anterior mandibular fracturesConventional and 3D miniplateMaximum bite forceORIF
spellingShingle Shital Patel
Kruna Bhimani
Roma Narsingyani
Zenish Bhatti
Rajan Savani
Is “Bite force” a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?
Journal of Oral Biology and Craniofacial Research
Anterior mandibular fractures
Conventional and 3D miniplate
Maximum bite force
ORIF
title Is “Bite force” a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?
title_full Is “Bite force” a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?
title_fullStr Is “Bite force” a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?
title_full_unstemmed Is “Bite force” a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?
title_short Is “Bite force” a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?
title_sort is bite force a reliable parameter to compare masticatory efficiency restoration following orif of anterior mandibular fractures
topic Anterior mandibular fractures
Conventional and 3D miniplate
Maximum bite force
ORIF
url http://www.sciencedirect.com/science/article/pii/S2212426822001257
work_keys_str_mv AT shitalpatel isbiteforceareliableparametertocomparemasticatoryefficiencyrestorationfollowingorifofanteriormandibularfractures
AT krunabhimani isbiteforceareliableparametertocomparemasticatoryefficiencyrestorationfollowingorifofanteriormandibularfractures
AT romanarsingyani isbiteforceareliableparametertocomparemasticatoryefficiencyrestorationfollowingorifofanteriormandibularfractures
AT zenishbhatti isbiteforceareliableparametertocomparemasticatoryefficiencyrestorationfollowingorifofanteriormandibularfractures
AT rajansavani isbiteforceareliableparametertocomparemasticatoryefficiencyrestorationfollowingorifofanteriormandibularfractures