Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition

For the voltage source converter based high voltage direct current (VSC-HVDC) station equipped with hybrid DC breakers, the DC circuit breaker has fast speed for breaking fault current and short time for internal commutation. The electromagnetic influence of magnetic field caused by fault current on...

Full description

Saved in:
Bibliographic Details
Main Authors: Meng BAO, Hong SHEN, Jialiang LI, Yan SHI, Lei QI, Qian WANG
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2021-10-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202012100
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850030136876859392
author Meng BAO
Hong SHEN
Jialiang LI
Yan SHI
Lei QI
Qian WANG
author_facet Meng BAO
Hong SHEN
Jialiang LI
Yan SHI
Lei QI
Qian WANG
author_sort Meng BAO
collection DOAJ
description For the voltage source converter based high voltage direct current (VSC-HVDC) station equipped with hybrid DC breakers, the DC circuit breaker has fast speed for breaking fault current and short time for internal commutation. The electromagnetic influence of magnetic field caused by fault current on secondary equipment in DC field is not clear. A multi-path magnetic field calculation model of hybrid DC circuit breaker and a magnetic field calculation model of smoothing reactor and DC bus are established to predict the magnetic field around the secondary equipment in the DC field of Dinghai Converter Station and Zhangbei Converter Station with bipolar short circuit fault at the DC side, and the distribution characteristics of magnetic field in the DC yard is obtained. The calculation results show that the peak value of magnetic field intensity around the existing secondary equipment in the DC field of Dinghai Converter Station and Zhangbei Converter Station can reach 883 A/m and 362 A/m respectively; the peak value of magnetic field intensity occurs at the time when the fault current reaches its peak value or the DC breaker has the second commutation; the magnetic field intensity is higher near the smoothing reactor and at the location where there are many buses in the DC yard. The calculation results can provide a reference for the evaluation of secondary equipment immunity and the layout of electrical equipment.
format Article
id doaj-art-d1a86f3ed50e4c12b983f2cfbea59e95
institution DOAJ
issn 1004-9649
language zho
publishDate 2021-10-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-d1a86f3ed50e4c12b983f2cfbea59e952025-08-20T02:59:18ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492021-10-015410556210.11930/j.issn.1004-9649.202012100zgdl-54-07-baomengModeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit ConditionMeng BAO0Hong SHEN1Jialiang LI2Yan SHI3Lei QI4Qian WANG5State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Grid Beijing Electric Power Research Institute, Beijing 100075, ChinaFor the voltage source converter based high voltage direct current (VSC-HVDC) station equipped with hybrid DC breakers, the DC circuit breaker has fast speed for breaking fault current and short time for internal commutation. The electromagnetic influence of magnetic field caused by fault current on secondary equipment in DC field is not clear. A multi-path magnetic field calculation model of hybrid DC circuit breaker and a magnetic field calculation model of smoothing reactor and DC bus are established to predict the magnetic field around the secondary equipment in the DC field of Dinghai Converter Station and Zhangbei Converter Station with bipolar short circuit fault at the DC side, and the distribution characteristics of magnetic field in the DC yard is obtained. The calculation results show that the peak value of magnetic field intensity around the existing secondary equipment in the DC field of Dinghai Converter Station and Zhangbei Converter Station can reach 883 A/m and 362 A/m respectively; the peak value of magnetic field intensity occurs at the time when the fault current reaches its peak value or the DC breaker has the second commutation; the magnetic field intensity is higher near the smoothing reactor and at the location where there are many buses in the DC yard. The calculation results can provide a reference for the evaluation of secondary equipment immunity and the layout of electrical equipment.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202012100vsc-hvdc converter stationhybrid dc breakershort circuit faultmagnetic field calculationelectromagnetic compatibility
spellingShingle Meng BAO
Hong SHEN
Jialiang LI
Yan SHI
Lei QI
Qian WANG
Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition
Zhongguo dianli
vsc-hvdc converter station
hybrid dc breaker
short circuit fault
magnetic field calculation
electromagnetic compatibility
title Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition
title_full Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition
title_fullStr Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition
title_full_unstemmed Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition
title_short Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition
title_sort modeling and prediction analysis of magnetic field in dc yard of vsc hvdc station under short circuit condition
topic vsc-hvdc converter station
hybrid dc breaker
short circuit fault
magnetic field calculation
electromagnetic compatibility
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202012100
work_keys_str_mv AT mengbao modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition
AT hongshen modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition
AT jialiangli modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition
AT yanshi modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition
AT leiqi modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition
AT qianwang modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition