Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition
For the voltage source converter based high voltage direct current (VSC-HVDC) station equipped with hybrid DC breakers, the DC circuit breaker has fast speed for breaking fault current and short time for internal commutation. The electromagnetic influence of magnetic field caused by fault current on...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
State Grid Energy Research Institute
2021-10-01
|
| Series: | Zhongguo dianli |
| Subjects: | |
| Online Access: | https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202012100 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850030136876859392 |
|---|---|
| author | Meng BAO Hong SHEN Jialiang LI Yan SHI Lei QI Qian WANG |
| author_facet | Meng BAO Hong SHEN Jialiang LI Yan SHI Lei QI Qian WANG |
| author_sort | Meng BAO |
| collection | DOAJ |
| description | For the voltage source converter based high voltage direct current (VSC-HVDC) station equipped with hybrid DC breakers, the DC circuit breaker has fast speed for breaking fault current and short time for internal commutation. The electromagnetic influence of magnetic field caused by fault current on secondary equipment in DC field is not clear. A multi-path magnetic field calculation model of hybrid DC circuit breaker and a magnetic field calculation model of smoothing reactor and DC bus are established to predict the magnetic field around the secondary equipment in the DC field of Dinghai Converter Station and Zhangbei Converter Station with bipolar short circuit fault at the DC side, and the distribution characteristics of magnetic field in the DC yard is obtained. The calculation results show that the peak value of magnetic field intensity around the existing secondary equipment in the DC field of Dinghai Converter Station and Zhangbei Converter Station can reach 883 A/m and 362 A/m respectively; the peak value of magnetic field intensity occurs at the time when the fault current reaches its peak value or the DC breaker has the second commutation; the magnetic field intensity is higher near the smoothing reactor and at the location where there are many buses in the DC yard. The calculation results can provide a reference for the evaluation of secondary equipment immunity and the layout of electrical equipment. |
| format | Article |
| id | doaj-art-d1a86f3ed50e4c12b983f2cfbea59e95 |
| institution | DOAJ |
| issn | 1004-9649 |
| language | zho |
| publishDate | 2021-10-01 |
| publisher | State Grid Energy Research Institute |
| record_format | Article |
| series | Zhongguo dianli |
| spelling | doaj-art-d1a86f3ed50e4c12b983f2cfbea59e952025-08-20T02:59:18ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492021-10-015410556210.11930/j.issn.1004-9649.202012100zgdl-54-07-baomengModeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit ConditionMeng BAO0Hong SHEN1Jialiang LI2Yan SHI3Lei QI4Qian WANG5State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, ChinaState Grid Beijing Electric Power Research Institute, Beijing 100075, ChinaFor the voltage source converter based high voltage direct current (VSC-HVDC) station equipped with hybrid DC breakers, the DC circuit breaker has fast speed for breaking fault current and short time for internal commutation. The electromagnetic influence of magnetic field caused by fault current on secondary equipment in DC field is not clear. A multi-path magnetic field calculation model of hybrid DC circuit breaker and a magnetic field calculation model of smoothing reactor and DC bus are established to predict the magnetic field around the secondary equipment in the DC field of Dinghai Converter Station and Zhangbei Converter Station with bipolar short circuit fault at the DC side, and the distribution characteristics of magnetic field in the DC yard is obtained. The calculation results show that the peak value of magnetic field intensity around the existing secondary equipment in the DC field of Dinghai Converter Station and Zhangbei Converter Station can reach 883 A/m and 362 A/m respectively; the peak value of magnetic field intensity occurs at the time when the fault current reaches its peak value or the DC breaker has the second commutation; the magnetic field intensity is higher near the smoothing reactor and at the location where there are many buses in the DC yard. The calculation results can provide a reference for the evaluation of secondary equipment immunity and the layout of electrical equipment.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202012100vsc-hvdc converter stationhybrid dc breakershort circuit faultmagnetic field calculationelectromagnetic compatibility |
| spellingShingle | Meng BAO Hong SHEN Jialiang LI Yan SHI Lei QI Qian WANG Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition Zhongguo dianli vsc-hvdc converter station hybrid dc breaker short circuit fault magnetic field calculation electromagnetic compatibility |
| title | Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition |
| title_full | Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition |
| title_fullStr | Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition |
| title_full_unstemmed | Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition |
| title_short | Modeling and Prediction Analysis of Magnetic Field in DC Yard of VSC-HVDC Station under Short Circuit Condition |
| title_sort | modeling and prediction analysis of magnetic field in dc yard of vsc hvdc station under short circuit condition |
| topic | vsc-hvdc converter station hybrid dc breaker short circuit fault magnetic field calculation electromagnetic compatibility |
| url | https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202012100 |
| work_keys_str_mv | AT mengbao modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition AT hongshen modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition AT jialiangli modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition AT yanshi modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition AT leiqi modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition AT qianwang modelingandpredictionanalysisofmagneticfieldindcyardofvschvdcstationundershortcircuitcondition |