A Prototype Mechatronic Device for Upper Limb Rehabilitation and Analysis of Its Functionality

A prototype device was developed as a simple yet effective tool for the rehabilitation of individuals with upper limb paresis resulting from stroke. The primary objective of the design process was to create a portable rehabilitation device that could be remotely controlled by a therapist via a Bluet...

Full description

Saved in:
Bibliographic Details
Main Authors: Jacek S. Tutak, Jacek Mucha
Format: Article
Language:English
Published: MDPI AG 2025-06-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/15/12/6613
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850156655447113728
author Jacek S. Tutak
Jacek Mucha
author_facet Jacek S. Tutak
Jacek Mucha
author_sort Jacek S. Tutak
collection DOAJ
description A prototype device was developed as a simple yet effective tool for the rehabilitation of individuals with upper limb paresis resulting from stroke. The primary objective of the design process was to create a portable rehabilitation device that could be remotely controlled by a therapist via a Bluetooth protocol. The device enables the execution of upper limb rehabilitation exercises and integrates essential modules for assessment, reporting, and user feedback (biofeedback). It comprises a base and three movable arms, each fitted with a container at its distal end. The central arm, positioned at the midpoint of the device’s housing, holds a storage container from which specific objects are retrieved by the user. This arm features an adjustable reach. The remaining two arms are equipped with task-specific containers mounted at their ends. The conceptual framework is based on the execution of various tasks displayed on a screen. The user retrieves objects from the central storage unit and places them into either the left or right container, as indicated. The target container is highlighted both visually on the screen and via an illuminated LED indicator. Pre-programmed sequences for object retrieval and placement are presented on the display, offering clear guidance for the correct positioning and ordering of blocks within the designated containers. The device includes 12 dedicated blocks varying in shape, colour, material, and texture. A mechatronic control system governs the container positioning and arm inclination, enabling a precise adjustment of range of movement according to the exercise’s requirements. A dedicated software system has also been developed for control and management. Functional testing of the prototype was conducted to assess the device’s effectiveness and practical applicability in rehabilitation settings.
format Article
id doaj-art-d18c657f22a14f30828ab5ae4f75daed
institution OA Journals
issn 2076-3417
language English
publishDate 2025-06-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj-art-d18c657f22a14f30828ab5ae4f75daed2025-08-20T02:24:26ZengMDPI AGApplied Sciences2076-34172025-06-011512661310.3390/app15126613A Prototype Mechatronic Device for Upper Limb Rehabilitation and Analysis of Its FunctionalityJacek S. Tutak0Jacek Mucha1Department of Applied Mechanics and Robotics, The Faculty of Mechanical Engineering and Aeronautics, Rzeszów University of Technology, Al. Powstańców Warszawy 8, 35-959 Rzeszów, PolandDepartment of Mechanical Engineering, The Faculty of Mechanical Engineering and Aeronautics, Rzeszów University of Technology, Al. Powstańców Warszawy 8, 35-959 Rzeszów, PolandA prototype device was developed as a simple yet effective tool for the rehabilitation of individuals with upper limb paresis resulting from stroke. The primary objective of the design process was to create a portable rehabilitation device that could be remotely controlled by a therapist via a Bluetooth protocol. The device enables the execution of upper limb rehabilitation exercises and integrates essential modules for assessment, reporting, and user feedback (biofeedback). It comprises a base and three movable arms, each fitted with a container at its distal end. The central arm, positioned at the midpoint of the device’s housing, holds a storage container from which specific objects are retrieved by the user. This arm features an adjustable reach. The remaining two arms are equipped with task-specific containers mounted at their ends. The conceptual framework is based on the execution of various tasks displayed on a screen. The user retrieves objects from the central storage unit and places them into either the left or right container, as indicated. The target container is highlighted both visually on the screen and via an illuminated LED indicator. Pre-programmed sequences for object retrieval and placement are presented on the display, offering clear guidance for the correct positioning and ordering of blocks within the designated containers. The device includes 12 dedicated blocks varying in shape, colour, material, and texture. A mechatronic control system governs the container positioning and arm inclination, enabling a precise adjustment of range of movement according to the exercise’s requirements. A dedicated software system has also been developed for control and management. Functional testing of the prototype was conducted to assess the device’s effectiveness and practical applicability in rehabilitation settings.https://www.mdpi.com/2076-3417/15/12/6613rehabilitation deviceupper limb rehabilitationcontrol rehabilitationmechatronics controlmobile mechatronic systems
spellingShingle Jacek S. Tutak
Jacek Mucha
A Prototype Mechatronic Device for Upper Limb Rehabilitation and Analysis of Its Functionality
Applied Sciences
rehabilitation device
upper limb rehabilitation
control rehabilitation
mechatronics control
mobile mechatronic systems
title A Prototype Mechatronic Device for Upper Limb Rehabilitation and Analysis of Its Functionality
title_full A Prototype Mechatronic Device for Upper Limb Rehabilitation and Analysis of Its Functionality
title_fullStr A Prototype Mechatronic Device for Upper Limb Rehabilitation and Analysis of Its Functionality
title_full_unstemmed A Prototype Mechatronic Device for Upper Limb Rehabilitation and Analysis of Its Functionality
title_short A Prototype Mechatronic Device for Upper Limb Rehabilitation and Analysis of Its Functionality
title_sort prototype mechatronic device for upper limb rehabilitation and analysis of its functionality
topic rehabilitation device
upper limb rehabilitation
control rehabilitation
mechatronics control
mobile mechatronic systems
url https://www.mdpi.com/2076-3417/15/12/6613
work_keys_str_mv AT jacekstutak aprototypemechatronicdeviceforupperlimbrehabilitationandanalysisofitsfunctionality
AT jacekmucha aprototypemechatronicdeviceforupperlimbrehabilitationandanalysisofitsfunctionality
AT jacekstutak prototypemechatronicdeviceforupperlimbrehabilitationandanalysisofitsfunctionality
AT jacekmucha prototypemechatronicdeviceforupperlimbrehabilitationandanalysisofitsfunctionality