Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits
Early detection of any disease is always a life-saving methodology for human beings likewise the detection of p24 antigen is always better than the detection of HIV antibodies. In the current era, p24 antigen is added additionally in HIV antibodies detection assays and called HIV fourth-generation i...
Saved in:
| Main Authors: | , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wolters Kluwer Medknow Publications
2024-12-01
|
| Series: | Asian Journal of Transfusion Science |
| Subjects: | |
| Online Access: | https://journals.lww.com/10.4103/ajts.ajts_224_23 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850080904742961152 |
|---|---|
| author | Rajesh Kumar Sharma Bharti Chauhan Ashrat Manzoor Rajeev Kumar Daud Ali Rich Baranwal Akanksha Bisht Harish Chander Anup Anvikar |
| author_facet | Rajesh Kumar Sharma Bharti Chauhan Ashrat Manzoor Rajeev Kumar Daud Ali Rich Baranwal Akanksha Bisht Harish Chander Anup Anvikar |
| author_sort | Rajesh Kumar Sharma |
| collection | DOAJ |
| description | Early detection of any disease is always a life-saving methodology for human beings likewise the detection of p24 antigen is always better than the detection of HIV antibodies. In the current era, p24 antigen is added additionally in HIV antibodies detection assays and called HIV fourth-generation immunodiagnostic kit. The different HIV fourth-generation kit having different capacities to pick up the low concentration of analyte as well as represent the detection values in different units. A total of 30 assays were used in this study and it was found that the detection concentration assigned by the manufacturers in the case of imported kits was 0.48 IU/mL to 2 IU/mL. However, the detection range of the indigenous kits was 25 pg/mL to 1000 IU/mL. This study gives an idea/knowledge for the startups concerned with high hope and broad scope for make in India concept in the IVDs market. |
| format | Article |
| id | doaj-art-d0bd732fe4a84407b5044ecb0dce28b1 |
| institution | DOAJ |
| issn | 0973-6247 1998-3565 |
| language | English |
| publishDate | 2024-12-01 |
| publisher | Wolters Kluwer Medknow Publications |
| record_format | Article |
| series | Asian Journal of Transfusion Science |
| spelling | doaj-art-d0bd732fe4a84407b5044ecb0dce28b12025-08-20T02:44:50ZengWolters Kluwer Medknow PublicationsAsian Journal of Transfusion Science0973-62471998-35652024-12-0118235936210.4103/ajts.ajts_224_23Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kitsRajesh Kumar SharmaBharti ChauhanAshrat ManzoorRajeev KumarDaud AliRich BaranwalAkanksha BishtHarish ChanderAnup AnvikarEarly detection of any disease is always a life-saving methodology for human beings likewise the detection of p24 antigen is always better than the detection of HIV antibodies. In the current era, p24 antigen is added additionally in HIV antibodies detection assays and called HIV fourth-generation immunodiagnostic kit. The different HIV fourth-generation kit having different capacities to pick up the low concentration of analyte as well as represent the detection values in different units. A total of 30 assays were used in this study and it was found that the detection concentration assigned by the manufacturers in the case of imported kits was 0.48 IU/mL to 2 IU/mL. However, the detection range of the indigenous kits was 25 pg/mL to 1000 IU/mL. This study gives an idea/knowledge for the startups concerned with high hope and broad scope for make in India concept in the IVDs market.https://journals.lww.com/10.4103/ajts.ajts_224_23detection concentrationhivp24 antigen |
| spellingShingle | Rajesh Kumar Sharma Bharti Chauhan Ashrat Manzoor Rajeev Kumar Daud Ali Rich Baranwal Akanksha Bisht Harish Chander Anup Anvikar Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits Asian Journal of Transfusion Science detection concentration hiv p24 antigen |
| title | Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits |
| title_full | Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits |
| title_fullStr | Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits |
| title_full_unstemmed | Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits |
| title_short | Comparison: Imported and Indigenous HIV Fourth-generation immunodiagnostic kits |
| title_sort | comparison imported and indigenous hiv fourth generation immunodiagnostic kits |
| topic | detection concentration hiv p24 antigen |
| url | https://journals.lww.com/10.4103/ajts.ajts_224_23 |
| work_keys_str_mv | AT rajeshkumarsharma comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits AT bhartichauhan comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits AT ashratmanzoor comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits AT rajeevkumar comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits AT daudali comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits AT richbaranwal comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits AT akankshabisht comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits AT harishchander comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits AT anupanvikar comparisonimportedandindigenoushivfourthgenerationimmunodiagnostickits |