Improvement and Validation of System Code for Thermal-hydraulic Analysis of In-pool Passive Residual Heat Removal System

After Fukushima nuclear accident, the passive concept is widely adopted in the thermal safety design of advanced nuclear reactors. The in-pool passive residual heat removal system (PRHRS) can also provide security guarantee for the domestic reactor HPR1000 without driving of the external power. Alth...

Full description

Saved in:
Bibliographic Details
Main Author: LIAN Qiang1, 2, 3, ZHU Longxiang1, 2, 3, TANG Simiao1, 2, 3, HUANG Tao4, ZHANG Yong4, PAN Liangming1, 2
Format: Article
Language:English
Published: Editorial Board of Atomic Energy Science and Technology 2025-04-01
Series:Yuanzineng kexue jishu
Subjects:
Online Access:https://yznkxjs.xml-journal.net/article/doi/10.7538/yzk.2024.youxian.0626
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850204105423716352
author LIAN Qiang1, 2, 3, ZHU Longxiang1, 2, 3, TANG Simiao1, 2, 3, HUANG Tao4, ZHANG Yong4, PAN Liangming1, 2
author_facet LIAN Qiang1, 2, 3, ZHU Longxiang1, 2, 3, TANG Simiao1, 2, 3, HUANG Tao4, ZHANG Yong4, PAN Liangming1, 2
author_sort LIAN Qiang1, 2, 3, ZHU Longxiang1, 2, 3, TANG Simiao1, 2, 3, HUANG Tao4, ZHANG Yong4, PAN Liangming1, 2
collection DOAJ
description After Fukushima nuclear accident, the passive concept is widely adopted in the thermal safety design of advanced nuclear reactors. The in-pool passive residual heat removal system (PRHRS) can also provide security guarantee for the domestic reactor HPR1000 without driving of the external power. Although RELAP5 code has been extensively validated for thermal-hydraulic transients in nuclear reactor, it underestimates the heat exchanging power and the system flow rate in the in-pool PRHRS due to the lack of specialized model for in-pool heat exchanger. Therefore, the model development for the in-pool heat exchanger is necessary for accurate simulation of PRHRS and safety assessment of the reactor system. In this study, the in-pool bundle boiling model and large-diameter tube condensation model were selected and implemented in RELAP5 code as the in-pool heat exchanger model. Firstly, the relevant heat transfer models in original RELAP5 were evaluated. The results show that Chen correlation developed initially for in-tube boiling is not suitable for bundle boiling heat transfer. Thus Cooper correlation developed initially for in-pool boiling considering the surface roughness is used to replace Chen correlation for the bundle geometry. On the other hand, the calculation in original RELAP5 for in-tube condensation encounters some faults under the condition with low gas speed in the natural circulation of PRHRS. The Shah method modified through fluid viscosity and pressure is chosen for the calculation of condensation heat transfer coefficient in the large-diameter tube. Secondly, the separate effect validation was carried out for the two heat transfer models. For the validation of in-pool bundle boiling model, the root-mean-square error of the heat transfer coefficient predicted by the improved RELAP5 is reduced to 16.2%, compared to the value of 53.8% obtained by the original code. For the validation of in-tube condensation model, the root-mean-square error of the heat flux predicted by the improved RELAP5 is reduced from 10.9% to 7.6%. Both models are improved effectively. After that, the influence of nodalization method was analyzed based on the in-pool energy removal system for emergency operation (PERSTO) facility. It is shown that the nodalization for the heat exchanger and pool has important influence on the thermal-hydraulic simulation of PERSTO. The pool should be modelled as at least two hydraulic components and the volume size of the heat exchanger along the flow direction should be less than 0.09 m. Finally, the simulation capabilities of the original RELAP5 and the improved code were compared based on the transient parameters of the integral experimental facility. The heat exchanger power and the flow rate in the natural circulation predicted by the improved RELAP5 are consistent with the experimental data. Then the improved code in this study is confirmed for thermal-hydraulic analysis of in-pool PRHRS after separate effect validation and integral effect validation. This study can provide the basic technology support for the structure design of PRHRS and safety analysis of the reactor system.
format Article
id doaj-art-cfc8a35433ce41eba6b143e898e4a269
institution OA Journals
issn 1000-6931
language English
publishDate 2025-04-01
publisher Editorial Board of Atomic Energy Science and Technology
record_format Article
series Yuanzineng kexue jishu
spelling doaj-art-cfc8a35433ce41eba6b143e898e4a2692025-08-20T02:11:21ZengEditorial Board of Atomic Energy Science and TechnologyYuanzineng kexue jishu1000-69312025-04-0159485886610.7538/yzk.2024.youxian.0626Improvement and Validation of System Code for Thermal-hydraulic Analysis of In-pool Passive Residual Heat Removal SystemLIAN Qiang1, 2, 3, ZHU Longxiang1, 2, 3, TANG Simiao1, 2, 3, HUANG Tao4, ZHANG Yong4, PAN Liangming1, 201. Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China 2. Department of Nuclear Engineering and Technology, Chongqing University, Chongqing 400044, China 3. Postdoctoral Station of Power Engineering and Engineering Thermophysics, Chongqing University, Chongqing 400044, China 4. Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu 610213, ChinaAfter Fukushima nuclear accident, the passive concept is widely adopted in the thermal safety design of advanced nuclear reactors. The in-pool passive residual heat removal system (PRHRS) can also provide security guarantee for the domestic reactor HPR1000 without driving of the external power. Although RELAP5 code has been extensively validated for thermal-hydraulic transients in nuclear reactor, it underestimates the heat exchanging power and the system flow rate in the in-pool PRHRS due to the lack of specialized model for in-pool heat exchanger. Therefore, the model development for the in-pool heat exchanger is necessary for accurate simulation of PRHRS and safety assessment of the reactor system. In this study, the in-pool bundle boiling model and large-diameter tube condensation model were selected and implemented in RELAP5 code as the in-pool heat exchanger model. Firstly, the relevant heat transfer models in original RELAP5 were evaluated. The results show that Chen correlation developed initially for in-tube boiling is not suitable for bundle boiling heat transfer. Thus Cooper correlation developed initially for in-pool boiling considering the surface roughness is used to replace Chen correlation for the bundle geometry. On the other hand, the calculation in original RELAP5 for in-tube condensation encounters some faults under the condition with low gas speed in the natural circulation of PRHRS. The Shah method modified through fluid viscosity and pressure is chosen for the calculation of condensation heat transfer coefficient in the large-diameter tube. Secondly, the separate effect validation was carried out for the two heat transfer models. For the validation of in-pool bundle boiling model, the root-mean-square error of the heat transfer coefficient predicted by the improved RELAP5 is reduced to 16.2%, compared to the value of 53.8% obtained by the original code. For the validation of in-tube condensation model, the root-mean-square error of the heat flux predicted by the improved RELAP5 is reduced from 10.9% to 7.6%. Both models are improved effectively. After that, the influence of nodalization method was analyzed based on the in-pool energy removal system for emergency operation (PERSTO) facility. It is shown that the nodalization for the heat exchanger and pool has important influence on the thermal-hydraulic simulation of PERSTO. The pool should be modelled as at least two hydraulic components and the volume size of the heat exchanger along the flow direction should be less than 0.09 m. Finally, the simulation capabilities of the original RELAP5 and the improved code were compared based on the transient parameters of the integral experimental facility. The heat exchanger power and the flow rate in the natural circulation predicted by the improved RELAP5 are consistent with the experimental data. Then the improved code in this study is confirmed for thermal-hydraulic analysis of in-pool PRHRS after separate effect validation and integral effect validation. This study can provide the basic technology support for the structure design of PRHRS and safety analysis of the reactor system. https://yznkxjs.xml-journal.net/article/doi/10.7538/yzk.2024.youxian.0626in-pool passive residual heat removal systemthermal-hydraulicssystem code improvementnodalization methodmodel validation
spellingShingle LIAN Qiang1, 2, 3, ZHU Longxiang1, 2, 3, TANG Simiao1, 2, 3, HUANG Tao4, ZHANG Yong4, PAN Liangming1, 2
Improvement and Validation of System Code for Thermal-hydraulic Analysis of In-pool Passive Residual Heat Removal System
Yuanzineng kexue jishu
in-pool passive residual heat removal system
thermal-hydraulics
system code improvement
nodalization method
model validation
title Improvement and Validation of System Code for Thermal-hydraulic Analysis of In-pool Passive Residual Heat Removal System
title_full Improvement and Validation of System Code for Thermal-hydraulic Analysis of In-pool Passive Residual Heat Removal System
title_fullStr Improvement and Validation of System Code for Thermal-hydraulic Analysis of In-pool Passive Residual Heat Removal System
title_full_unstemmed Improvement and Validation of System Code for Thermal-hydraulic Analysis of In-pool Passive Residual Heat Removal System
title_short Improvement and Validation of System Code for Thermal-hydraulic Analysis of In-pool Passive Residual Heat Removal System
title_sort improvement and validation of system code for thermal hydraulic analysis of in pool passive residual heat removal system
topic in-pool passive residual heat removal system
thermal-hydraulics
system code improvement
nodalization method
model validation
url https://yznkxjs.xml-journal.net/article/doi/10.7538/yzk.2024.youxian.0626
work_keys_str_mv AT lianqiang123zhulongxiang123tangsimiao123huangtao4zhangyong4panliangming12 improvementandvalidationofsystemcodeforthermalhydraulicanalysisofinpoolpassiveresidualheatremovalsystem