Research on Suspended Monorail Traction Power Return Grounding Fault Detection Protection Mechanism

The traction power return grounding fault of suspended monorail in station will lead to large-scale tripping of circuit breakers of other trains and adjacent traction substations. In order to avoid the impact on other normal equipment, and help maintenance personnel locking the fault area quickly an...

Full description

Saved in:
Bibliographic Details
Main Authors: ZHANG Kun, YUAN Wenye, LIU Xiang, WANG Lichao
Format: Article
Language:zho
Published: Editorial Department of Electric Drive for Locomotives 2018-01-01
Series:机车电传动
Subjects:
Online Access:http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2018.06.018
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The traction power return grounding fault of suspended monorail in station will lead to large-scale tripping of circuit breakers of other trains and adjacent traction substations. In order to avoid the impact on other normal equipment, and help maintenance personnel locking the fault area quickly and accurately, improvements were made by canceling the grounding overvoltage relay on the train and increasing the differential current detection device of the on-board equipment. Meanwhile, a hierarchical grounding detection and protection mechanism was proposed for the protection and fast positioning of traction power return grounding fault. The improved grounding protection device has been used on the test line, and the verification results shows that the protection mechanism could reduce the impact of the fault and improve the efficiency of train operation.
ISSN:1000-128X