Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid Chromatography

RP-HPLC analytical method for the estimation of nabumetone in pharmaceutical dosage forms was developed and validated. A Hypersil ODS C18, 4.6 mm x 250 mm, 5 μm column from Supelco (India), with mobile phase comprised of acetonitrile: triple distilled water (50:50) with a total run time of 18 min wa...

Full description

Saved in:
Bibliographic Details
Main Authors: Prafulla Kumar Sahu, M. Mathrusri Annapurna
Format: Article
Language:English
Published: Wiley 2009-01-01
Series:E-Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2009/795896
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850173333637693440
author Prafulla Kumar Sahu
M. Mathrusri Annapurna
author_facet Prafulla Kumar Sahu
M. Mathrusri Annapurna
author_sort Prafulla Kumar Sahu
collection DOAJ
description RP-HPLC analytical method for the estimation of nabumetone in pharmaceutical dosage forms was developed and validated. A Hypersil ODS C18, 4.6 mm x 250 mm, 5 μm column from Supelco (India), with mobile phase comprised of acetonitrile: triple distilled water (50:50) with a total run time of 18 min was used and the wavelength of the detector was set at 230 nm. Stavudin is used as internal standard. The retention times were 14.167 min and 1.967 min for nabumetone and stavudin (IS) respectively. The extraction recovery of nabumetone from pharmaceutical dosage form (tablets) was >101% and the calibration curve was linear (r2 = 0.995) over nabumetone concentrations ranging from 1 to 200 µg/mL. The method had an accuracy of >99% and LOD and LOQ of 0.17482 µg/mL and 0.5827 µg/mL respectively. The method reported is simple, reliable, precise and accurate and has the capability of being used for determination of nabumetone in bulk and pharmaceutical dosage forms.
format Article
id doaj-art-cd477f79127149f5a829ff294b1803e0
institution OA Journals
issn 0973-4945
2090-9810
language English
publishDate 2009-01-01
publisher Wiley
record_format Article
series E-Journal of Chemistry
spelling doaj-art-cd477f79127149f5a829ff294b1803e02025-08-20T02:19:52ZengWileyE-Journal of Chemistry0973-49452090-98102009-01-016S1S59S6410.1155/2009/795896Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid ChromatographyPrafulla Kumar Sahu0M. Mathrusri Annapurna1Gayatri Institute of Pharmaceutical Science and Technology, Gunupur, Rayagada, Orissa, IndiaDepartment of Pharmaceutical Analysis & Quality Assurance, Roland Institute of Pharmaceutical Sciences, Berhampur, Orissa, IndiaRP-HPLC analytical method for the estimation of nabumetone in pharmaceutical dosage forms was developed and validated. A Hypersil ODS C18, 4.6 mm x 250 mm, 5 μm column from Supelco (India), with mobile phase comprised of acetonitrile: triple distilled water (50:50) with a total run time of 18 min was used and the wavelength of the detector was set at 230 nm. Stavudin is used as internal standard. The retention times were 14.167 min and 1.967 min for nabumetone and stavudin (IS) respectively. The extraction recovery of nabumetone from pharmaceutical dosage form (tablets) was >101% and the calibration curve was linear (r2 = 0.995) over nabumetone concentrations ranging from 1 to 200 µg/mL. The method had an accuracy of >99% and LOD and LOQ of 0.17482 µg/mL and 0.5827 µg/mL respectively. The method reported is simple, reliable, precise and accurate and has the capability of being used for determination of nabumetone in bulk and pharmaceutical dosage forms.http://dx.doi.org/10.1155/2009/795896
spellingShingle Prafulla Kumar Sahu
M. Mathrusri Annapurna
Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid Chromatography
E-Journal of Chemistry
title Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid Chromatography
title_full Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid Chromatography
title_fullStr Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid Chromatography
title_full_unstemmed Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid Chromatography
title_short Analysis of Nabumetone in Bulk and Tablet Formulation by a New and Validated Reverse Phase High Performance Liquid Chromatography
title_sort analysis of nabumetone in bulk and tablet formulation by a new and validated reverse phase high performance liquid chromatography
url http://dx.doi.org/10.1155/2009/795896
work_keys_str_mv AT prafullakumarsahu analysisofnabumetoneinbulkandtabletformulationbyanewandvalidatedreversephasehighperformanceliquidchromatography
AT mmathrusriannapurna analysisofnabumetoneinbulkandtabletformulationbyanewandvalidatedreversephasehighperformanceliquidchromatography