Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams

The aim of the study was to investigate surface and buildup region doses for 6 MV and 15 MV photon beams using a Markus parallel-plate ionization chamber, GafChromic EBT3 film, and MOSFET detector for different field sizes and beam angles. The measurements were made in a water equivalent solid phant...

Full description

Saved in:
Bibliographic Details
Main Authors: Ugur Akbas, Nazmiye Donmez Kesen, Canan Koksal, Hatice Bilge
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:Advances in High Energy Physics
Online Access:http://dx.doi.org/10.1155/2016/8361028
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849696171840241664
author Ugur Akbas
Nazmiye Donmez Kesen
Canan Koksal
Hatice Bilge
author_facet Ugur Akbas
Nazmiye Donmez Kesen
Canan Koksal
Hatice Bilge
author_sort Ugur Akbas
collection DOAJ
description The aim of the study was to investigate surface and buildup region doses for 6 MV and 15 MV photon beams using a Markus parallel-plate ionization chamber, GafChromic EBT3 film, and MOSFET detector for different field sizes and beam angles. The measurements were made in a water equivalent solid phantom at the surface and in the buildup region of the 6 MV and 15 MV photon beams at 100 cm source-detector distance for 5 × 5, 10 × 10, and 20 × 20 cm2 field sizes and 0°, 30°, 60°, and 80° beam angles. The surface doses using 6 MV photon beams for 10 × 10 cm2 field size were found to be 20.3%, 18.8%, and 25.5% for Markus chamber, EBT3 film, and MOSFET detector, respectively. The surface doses using 15 MV photon beams for 10 × 10 cm2 field size were found to be 14.9%, 13.4%, and 16.4% for Markus chamber, EBT3 film, and MOSFET detector, respectively. The surface dose increased with field size for all dosimeters. As the angle of the incident radiation beam became more oblique, the surface dose increased. The effective measurement depths of dosimeters vary; thus, the results of the measurements could be different. This issue can lead to mistakes at surface and buildup dosimetry and must be taken into account.
format Article
id doaj-art-cc532d4665d048fc9f8ad34d574ae0e0
institution DOAJ
issn 1687-7357
1687-7365
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series Advances in High Energy Physics
spelling doaj-art-cc532d4665d048fc9f8ad34d574ae0e02025-08-20T03:19:32ZengWileyAdvances in High Energy Physics1687-73571687-73652016-01-01201610.1155/2016/83610288361028Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon BeamsUgur Akbas0Nazmiye Donmez Kesen1Canan Koksal2Hatice Bilge3Division of Medical Physics, Istanbul University Oncology Institute, Istanbul, TurkeyDivision of Medical Physics, Istanbul University Oncology Institute, Istanbul, TurkeyDivision of Medical Physics, Istanbul University Oncology Institute, Istanbul, TurkeyDivision of Medical Physics, Istanbul University Oncology Institute, Istanbul, TurkeyThe aim of the study was to investigate surface and buildup region doses for 6 MV and 15 MV photon beams using a Markus parallel-plate ionization chamber, GafChromic EBT3 film, and MOSFET detector for different field sizes and beam angles. The measurements were made in a water equivalent solid phantom at the surface and in the buildup region of the 6 MV and 15 MV photon beams at 100 cm source-detector distance for 5 × 5, 10 × 10, and 20 × 20 cm2 field sizes and 0°, 30°, 60°, and 80° beam angles. The surface doses using 6 MV photon beams for 10 × 10 cm2 field size were found to be 20.3%, 18.8%, and 25.5% for Markus chamber, EBT3 film, and MOSFET detector, respectively. The surface doses using 15 MV photon beams for 10 × 10 cm2 field size were found to be 14.9%, 13.4%, and 16.4% for Markus chamber, EBT3 film, and MOSFET detector, respectively. The surface dose increased with field size for all dosimeters. As the angle of the incident radiation beam became more oblique, the surface dose increased. The effective measurement depths of dosimeters vary; thus, the results of the measurements could be different. This issue can lead to mistakes at surface and buildup dosimetry and must be taken into account.http://dx.doi.org/10.1155/2016/8361028
spellingShingle Ugur Akbas
Nazmiye Donmez Kesen
Canan Koksal
Hatice Bilge
Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams
Advances in High Energy Physics
title Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams
title_full Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams
title_fullStr Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams
title_full_unstemmed Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams
title_short Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams
title_sort surface and buildup region dose measurements with markus parallel plate ionization chamber gafchromic ebt3 film and mosfet detector for high energy photon beams
url http://dx.doi.org/10.1155/2016/8361028
work_keys_str_mv AT ugurakbas surfaceandbuildupregiondosemeasurementswithmarkusparallelplateionizationchambergafchromicebt3filmandmosfetdetectorforhighenergyphotonbeams
AT nazmiyedonmezkesen surfaceandbuildupregiondosemeasurementswithmarkusparallelplateionizationchambergafchromicebt3filmandmosfetdetectorforhighenergyphotonbeams
AT canankoksal surfaceandbuildupregiondosemeasurementswithmarkusparallelplateionizationchambergafchromicebt3filmandmosfetdetectorforhighenergyphotonbeams
AT haticebilge surfaceandbuildupregiondosemeasurementswithmarkusparallelplateionizationchambergafchromicebt3filmandmosfetdetectorforhighenergyphotonbeams