Comparative analysis of Microsoft Kinect Azure and manual measurement methods in the sit and reach test among elite female weightlifters

Abstract Microsoft Kinect is an increasingly common tool for low-cost and portable measurement of human movements. The aim of this study was to investigate the potential reliability and reproducibility of Microsoft Kinect Azure in the sit-and-reach test conducted under standardized test conditions i...

Full description

Saved in:
Bibliographic Details
Main Authors: Usame Ömer Osmanoğlu, Kenan Erdaği, Bülent IŞIK, Serkan Örücü, Erkan Özbay
Format: Article
Language:English
Published: Nature Portfolio 2025-07-01
Series:Scientific Reports
Subjects:
Online Access:https://doi.org/10.1038/s41598-025-09754-w
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849333360924557312
author Usame Ömer Osmanoğlu
Kenan Erdaği
Bülent IŞIK
Serkan Örücü
Erkan Özbay
author_facet Usame Ömer Osmanoğlu
Kenan Erdaği
Bülent IŞIK
Serkan Örücü
Erkan Özbay
author_sort Usame Ömer Osmanoğlu
collection DOAJ
description Abstract Microsoft Kinect is an increasingly common tool for low-cost and portable measurement of human movements. The aim of this study was to investigate the potential reliability and reproducibility of Microsoft Kinect Azure in the sit-and-reach test conducted under standardized test conditions in a controlled training environment with elite female weightlifters. The sit-and-reach test was performed with Microsoft Kinect Azure and manual methods and also the reliability and validity were analyzed by comparing the wrist, elbow, shoulder and trunk joint angle measurements with the digital goniometer. Twenty-one healthy female weightlifter athletes who won medals in international championships were included in the study. Sit-and-reach testing was performed using Microsoft Kinect Azure and manual methods in accordance with the standards of the American College of Sports Medicine. The flexion range of motions of each athlete’s wrist, elbow, shoulder and trunk joint angles were measured with a digital goniometer and Microsoft Kinect Azure. Statistical analyses were performed using IBM SPSS 25.0 and Python 3.9.12 software. Descriptive statistics were calculated for all variables, and differences between Kinect and manual methods were evaluated with the Mann-Whitney U test and Wilcoxon Signed-Rank Test. Linear relationships between measurements were analyzed with Spearman correlation coefficients. Intraclass Correlation Coefficient was calculated for the concordance analysis and presented with Bland-Altman plots. The level of significance was accepted as p < 0.05. The findings suggest that Kinect Azure may provide good reproducibility and agreement with manual goniometric measurements for joint angles under the specific structured conditions tested. For parameters such as the elbow, shoulder, wrist, trunk angles and distance traveled, high ICC values (> 0.90) indicated strong consistency between the methods. Kinect Azure may serve as a reliable alternative to manual measurement methods under standardized testing conditions. Further studies are recommended to examine its generalizability to other populations and test environments.
format Article
id doaj-art-cbdc55d5b9444e6b9ce7645d35f0079d
institution Kabale University
issn 2045-2322
language English
publishDate 2025-07-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj-art-cbdc55d5b9444e6b9ce7645d35f0079d2025-08-20T03:45:53ZengNature PortfolioScientific Reports2045-23222025-07-0115111810.1038/s41598-025-09754-wComparative analysis of Microsoft Kinect Azure and manual measurement methods in the sit and reach test among elite female weightliftersUsame Ömer Osmanoğlu0Kenan Erdaği1Bülent IŞIK2Serkan Örücü3Erkan Özbay4Departments of Biostatistics, Faculty of Medicine, University of Karamanoğlu MehmetbeyDepartments of Physical Education and Sports, Ahmet Keleşoğlu Faculty of Education, Necmettin Erbakan UniversityDepartments of Physiology, Faculty of Medicine, University of Karamanoğlu MehmetbeyComputer Technologies Program, Vocational School of Technical Sciences, Karamanoğlu Mehmetbey UniversityDepartment of Medical Services and Techniques, Health Services Vocational School, University of Karamanoğlu MehmetbeyAbstract Microsoft Kinect is an increasingly common tool for low-cost and portable measurement of human movements. The aim of this study was to investigate the potential reliability and reproducibility of Microsoft Kinect Azure in the sit-and-reach test conducted under standardized test conditions in a controlled training environment with elite female weightlifters. The sit-and-reach test was performed with Microsoft Kinect Azure and manual methods and also the reliability and validity were analyzed by comparing the wrist, elbow, shoulder and trunk joint angle measurements with the digital goniometer. Twenty-one healthy female weightlifter athletes who won medals in international championships were included in the study. Sit-and-reach testing was performed using Microsoft Kinect Azure and manual methods in accordance with the standards of the American College of Sports Medicine. The flexion range of motions of each athlete’s wrist, elbow, shoulder and trunk joint angles were measured with a digital goniometer and Microsoft Kinect Azure. Statistical analyses were performed using IBM SPSS 25.0 and Python 3.9.12 software. Descriptive statistics were calculated for all variables, and differences between Kinect and manual methods were evaluated with the Mann-Whitney U test and Wilcoxon Signed-Rank Test. Linear relationships between measurements were analyzed with Spearman correlation coefficients. Intraclass Correlation Coefficient was calculated for the concordance analysis and presented with Bland-Altman plots. The level of significance was accepted as p < 0.05. The findings suggest that Kinect Azure may provide good reproducibility and agreement with manual goniometric measurements for joint angles under the specific structured conditions tested. For parameters such as the elbow, shoulder, wrist, trunk angles and distance traveled, high ICC values (> 0.90) indicated strong consistency between the methods. Kinect Azure may serve as a reliable alternative to manual measurement methods under standardized testing conditions. Further studies are recommended to examine its generalizability to other populations and test environments.https://doi.org/10.1038/s41598-025-09754-wMicrosoft Kinect AzureSit-and-reachOlympic style weightliftingFlexibility
spellingShingle Usame Ömer Osmanoğlu
Kenan Erdaği
Bülent IŞIK
Serkan Örücü
Erkan Özbay
Comparative analysis of Microsoft Kinect Azure and manual measurement methods in the sit and reach test among elite female weightlifters
Scientific Reports
Microsoft Kinect Azure
Sit-and-reach
Olympic style weightlifting
Flexibility
title Comparative analysis of Microsoft Kinect Azure and manual measurement methods in the sit and reach test among elite female weightlifters
title_full Comparative analysis of Microsoft Kinect Azure and manual measurement methods in the sit and reach test among elite female weightlifters
title_fullStr Comparative analysis of Microsoft Kinect Azure and manual measurement methods in the sit and reach test among elite female weightlifters
title_full_unstemmed Comparative analysis of Microsoft Kinect Azure and manual measurement methods in the sit and reach test among elite female weightlifters
title_short Comparative analysis of Microsoft Kinect Azure and manual measurement methods in the sit and reach test among elite female weightlifters
title_sort comparative analysis of microsoft kinect azure and manual measurement methods in the sit and reach test among elite female weightlifters
topic Microsoft Kinect Azure
Sit-and-reach
Olympic style weightlifting
Flexibility
url https://doi.org/10.1038/s41598-025-09754-w
work_keys_str_mv AT usameomerosmanoglu comparativeanalysisofmicrosoftkinectazureandmanualmeasurementmethodsinthesitandreachtestamongelitefemaleweightlifters
AT kenanerdagi comparativeanalysisofmicrosoftkinectazureandmanualmeasurementmethodsinthesitandreachtestamongelitefemaleweightlifters
AT bulentisik comparativeanalysisofmicrosoftkinectazureandmanualmeasurementmethodsinthesitandreachtestamongelitefemaleweightlifters
AT serkanorucu comparativeanalysisofmicrosoftkinectazureandmanualmeasurementmethodsinthesitandreachtestamongelitefemaleweightlifters
AT erkanozbay comparativeanalysisofmicrosoftkinectazureandmanualmeasurementmethodsinthesitandreachtestamongelitefemaleweightlifters