PRIMO Monte Carlo Simulation and One-dimensional Gamma Index Analysis as a Tool to Validate Experimentally Measured Beam Data and Treatment Planning System Calculated Dose Distribution

Purpose: The purpose of this study was to validate experimentally measured beam data, and treatment planning system (TPS) calculated volumetric modulated arc therapy (VMAT) three-dimensional (3D) dose distribution using PRIMO Monte Carlo (MC) simulation and one-dimensional (1D) gamma index analysis....

Full description

Saved in:
Bibliographic Details
Main Authors: Ngangom Robert, Ranjit Singh, Arun S Oinam, Budhi Singh, Gaurav Trivedi
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2025-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:https://journals.lww.com/10.4103/jmp.jmp_194_24
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849768845265338368
author Ngangom Robert
Ranjit Singh
Arun S Oinam
Budhi Singh
Gaurav Trivedi
author_facet Ngangom Robert
Ranjit Singh
Arun S Oinam
Budhi Singh
Gaurav Trivedi
author_sort Ngangom Robert
collection DOAJ
description Purpose: The purpose of this study was to validate experimentally measured beam data, and treatment planning system (TPS) calculated volumetric modulated arc therapy (VMAT) three-dimensional (3D) dose distribution using PRIMO Monte Carlo (MC) simulation and one-dimensional (1D) gamma index analysis. Materials and Methods: The PRIMO code simulates the percentage depth dose (PDD) and beam profiles across varying field sizes in water phantoms, which were then compared with the ion chamber-measured beam characteristics using 1D gamma analysis. For the VMAT 3D dose distribution, the computed tomography scan of the anthropomorphic pelvis phantom was used for dose calculation and simulation in Eclipse TPS and PRIMO, respectively. Then, the doses of the target and organ at risk were compared with 1D gamma index analysis. Results: The results show that the PDD passed the 1D gamma index above 95% of all evaluated points at 2%/2 mm criteria. There was no significant difference between the mean values of measured and MC-simulated PDD at all field sizes. The results were statistically significant as P < 0.05. For beam profile at a 10 cm depth along in-line (in-plane) and cross-line (cross-plane) directions, above 95% of all the evaluated points passed the 1D gamma index at 3%/3 mm. The matching of dose volume histogram (DVH) of TPS calculated and PRIMO simulated DVH passed 2%/2 mm and 3%/3 mm gamma index passing criteria. Conclusions: Based on this study’s findings, PRIMO MC simulation can validate experimentally measured medical linear accelerator beam data and TPS 3D dose distribution with acceptable agreement using 1D gamma analysis.
format Article
id doaj-art-cb748fb2a69548c3bbff2e0266926c88
institution DOAJ
issn 0971-6203
1998-3913
language English
publishDate 2025-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Physics
spelling doaj-art-cb748fb2a69548c3bbff2e0266926c882025-08-20T03:03:40ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132025-01-01501606610.4103/jmp.jmp_194_24PRIMO Monte Carlo Simulation and One-dimensional Gamma Index Analysis as a Tool to Validate Experimentally Measured Beam Data and Treatment Planning System Calculated Dose DistributionNgangom RobertRanjit SinghArun S OinamBudhi SinghGaurav TrivediPurpose: The purpose of this study was to validate experimentally measured beam data, and treatment planning system (TPS) calculated volumetric modulated arc therapy (VMAT) three-dimensional (3D) dose distribution using PRIMO Monte Carlo (MC) simulation and one-dimensional (1D) gamma index analysis. Materials and Methods: The PRIMO code simulates the percentage depth dose (PDD) and beam profiles across varying field sizes in water phantoms, which were then compared with the ion chamber-measured beam characteristics using 1D gamma analysis. For the VMAT 3D dose distribution, the computed tomography scan of the anthropomorphic pelvis phantom was used for dose calculation and simulation in Eclipse TPS and PRIMO, respectively. Then, the doses of the target and organ at risk were compared with 1D gamma index analysis. Results: The results show that the PDD passed the 1D gamma index above 95% of all evaluated points at 2%/2 mm criteria. There was no significant difference between the mean values of measured and MC-simulated PDD at all field sizes. The results were statistically significant as P < 0.05. For beam profile at a 10 cm depth along in-line (in-plane) and cross-line (cross-plane) directions, above 95% of all the evaluated points passed the 1D gamma index at 3%/3 mm. The matching of dose volume histogram (DVH) of TPS calculated and PRIMO simulated DVH passed 2%/2 mm and 3%/3 mm gamma index passing criteria. Conclusions: Based on this study’s findings, PRIMO MC simulation can validate experimentally measured medical linear accelerator beam data and TPS 3D dose distribution with acceptable agreement using 1D gamma analysis.https://journals.lww.com/10.4103/jmp.jmp_194_24gamma indexmonte carlo simulationpenelopeprimo
spellingShingle Ngangom Robert
Ranjit Singh
Arun S Oinam
Budhi Singh
Gaurav Trivedi
PRIMO Monte Carlo Simulation and One-dimensional Gamma Index Analysis as a Tool to Validate Experimentally Measured Beam Data and Treatment Planning System Calculated Dose Distribution
Journal of Medical Physics
gamma index
monte carlo simulation
penelope
primo
title PRIMO Monte Carlo Simulation and One-dimensional Gamma Index Analysis as a Tool to Validate Experimentally Measured Beam Data and Treatment Planning System Calculated Dose Distribution
title_full PRIMO Monte Carlo Simulation and One-dimensional Gamma Index Analysis as a Tool to Validate Experimentally Measured Beam Data and Treatment Planning System Calculated Dose Distribution
title_fullStr PRIMO Monte Carlo Simulation and One-dimensional Gamma Index Analysis as a Tool to Validate Experimentally Measured Beam Data and Treatment Planning System Calculated Dose Distribution
title_full_unstemmed PRIMO Monte Carlo Simulation and One-dimensional Gamma Index Analysis as a Tool to Validate Experimentally Measured Beam Data and Treatment Planning System Calculated Dose Distribution
title_short PRIMO Monte Carlo Simulation and One-dimensional Gamma Index Analysis as a Tool to Validate Experimentally Measured Beam Data and Treatment Planning System Calculated Dose Distribution
title_sort primo monte carlo simulation and one dimensional gamma index analysis as a tool to validate experimentally measured beam data and treatment planning system calculated dose distribution
topic gamma index
monte carlo simulation
penelope
primo
url https://journals.lww.com/10.4103/jmp.jmp_194_24
work_keys_str_mv AT ngangomrobert primomontecarlosimulationandonedimensionalgammaindexanalysisasatooltovalidateexperimentallymeasuredbeamdataandtreatmentplanningsystemcalculateddosedistribution
AT ranjitsingh primomontecarlosimulationandonedimensionalgammaindexanalysisasatooltovalidateexperimentallymeasuredbeamdataandtreatmentplanningsystemcalculateddosedistribution
AT arunsoinam primomontecarlosimulationandonedimensionalgammaindexanalysisasatooltovalidateexperimentallymeasuredbeamdataandtreatmentplanningsystemcalculateddosedistribution
AT budhisingh primomontecarlosimulationandonedimensionalgammaindexanalysisasatooltovalidateexperimentallymeasuredbeamdataandtreatmentplanningsystemcalculateddosedistribution
AT gauravtrivedi primomontecarlosimulationandonedimensionalgammaindexanalysisasatooltovalidateexperimentallymeasuredbeamdataandtreatmentplanningsystemcalculateddosedistribution