THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2

The assessment of the suitability of cables of 6–110 kW with XLPE insulation in comparison with cables of the same voltage but possessing paper-oil insulation has been fulfilled on the basis of the method of multi-objective optimization that makes it possible to account not only the quantitative cha...

Full description

Saved in:
Bibliographic Details
Main Authors: M. A. Korotkevich, S. I. Podgaiskiy, A. V. Golomuzdov
Format: Article
Language:Russian
Published: Belarusian National Technical University 2017-11-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/1094
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849398674349621248
author M. A. Korotkevich
S. I. Podgaiskiy
A. V. Golomuzdov
author_facet M. A. Korotkevich
S. I. Podgaiskiy
A. V. Golomuzdov
author_sort M. A. Korotkevich
collection DOAJ
description The assessment of the suitability of cables of 6–110 kW with XLPE insulation in comparison with cables of the same voltage but possessing paper-oil insulation has been fulfilled on the basis of the method of multi-objective optimization that makes it possible to account not only the quantitative characteristics (of reduced costs), but also qualitative ones. As an indicator of the reliability of the cable line the maximum mean time to failure (the value inversely proportional to the parameter of succession of failures), which is an order more for cable lines with XLPE insulation than for cable lines with paper insulation, is adopted. A comprehensive assessment of the convenience of installation of cable lines revealed that the installation of cable with XLPE insulation features a 1.2–1.6 times easier installation as compared to three-wire (voltage 10 kW) and 1.4 times easier installation as compared to single-core oil-filled cables (voltage of 110 kW). The efficacy of the cables 6–110 kW with XLPE insulation is proved on the basis on the method of multi-objective optimization, that took into account as the costs for the construction and operation of cable lines and the reliability of its operation, ease of its installation and other quality indicators. If the goals taken into account are considered as equally important, the polyethylene-insulated cables for a voltage of 10–110 kW is more efficient as compared to three-wire (voltage 10 kW) and solid (110 kW) cables with paper insulation. Herewith, the cost of the cable with XLPE insulation may exceed the cost of cable with paper insulation up to two times. If the most important aim is to provide the minimum reduced costs for the construction and operation of the cable line, the use of cables with XLPE insulation for voltage of 10 kW is most advisable in individual cases.
format Article
id doaj-art-cb589c4f65204c74b67fe54b1ea9eba6
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2017-11-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-cb589c4f65204c74b67fe54b1ea9eba62025-08-20T03:38:31ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412017-11-0160650552210.21122/1029-7448-2017-60-6-505-5221055THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2M. A. Korotkevich0S. I. Podgaiskiy1A. V. Golomuzdov2Belarusian National Technical UniversityEnergokomplektEnergokomplektThe assessment of the suitability of cables of 6–110 kW with XLPE insulation in comparison with cables of the same voltage but possessing paper-oil insulation has been fulfilled on the basis of the method of multi-objective optimization that makes it possible to account not only the quantitative characteristics (of reduced costs), but also qualitative ones. As an indicator of the reliability of the cable line the maximum mean time to failure (the value inversely proportional to the parameter of succession of failures), which is an order more for cable lines with XLPE insulation than for cable lines with paper insulation, is adopted. A comprehensive assessment of the convenience of installation of cable lines revealed that the installation of cable with XLPE insulation features a 1.2–1.6 times easier installation as compared to three-wire (voltage 10 kW) and 1.4 times easier installation as compared to single-core oil-filled cables (voltage of 110 kW). The efficacy of the cables 6–110 kW with XLPE insulation is proved on the basis on the method of multi-objective optimization, that took into account as the costs for the construction and operation of cable lines and the reliability of its operation, ease of its installation and other quality indicators. If the goals taken into account are considered as equally important, the polyethylene-insulated cables for a voltage of 10–110 kW is more efficient as compared to three-wire (voltage 10 kW) and solid (110 kW) cables with paper insulation. Herewith, the cost of the cable with XLPE insulation may exceed the cost of cable with paper insulation up to two times. If the most important aim is to provide the minimum reduced costs for the construction and operation of the cable line, the use of cables with XLPE insulation for voltage of 10 kW is most advisable in individual cases.https://energy.bntu.by/jour/article/view/1094cable linesvoltage of 6–110 kwxlpepaper-oil insulationreliabilityease of installationmulti-purpose optimization
spellingShingle M. A. Korotkevich
S. I. Podgaiskiy
A. V. Golomuzdov
THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
cable lines
voltage of 6–110 kw
xlpe
paper-oil insulation
reliability
ease of installation
multi-purpose optimization
title THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_full THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_fullStr THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_full_unstemmed THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_short THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2
title_sort efficacy of the cables of 6 110 kw with xlpe insulation part 2
topic cable lines
voltage of 6–110 kw
xlpe
paper-oil insulation
reliability
ease of installation
multi-purpose optimization
url https://energy.bntu.by/jour/article/view/1094
work_keys_str_mv AT makorotkevich theefficacyofthecablesof6110kwwithxlpeinsulationpart2
AT sipodgaiskiy theefficacyofthecablesof6110kwwithxlpeinsulationpart2
AT avgolomuzdov theefficacyofthecablesof6110kwwithxlpeinsulationpart2
AT makorotkevich efficacyofthecablesof6110kwwithxlpeinsulationpart2
AT sipodgaiskiy efficacyofthecablesof6110kwwithxlpeinsulationpart2
AT avgolomuzdov efficacyofthecablesof6110kwwithxlpeinsulationpart2