Effects of local enemal matrix protein on osseointegration of different surface Titanium implants
The aim of this study is to investigate the osseointegration levels of implants with different surfaces locally applied with enamel matrix protein by biomechanical methods. Thirty adult female Spraque Dawley rats weighing 300–350 g were included in the study as subjects. The rats were divided into...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Universidad del Zulia
2025-05-01
|
| Series: | Revista Científica |
| Subjects: | |
| Online Access: | https://produccioncientificaluz.org/index.php/cientifica/article/view/43854 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849715908291854336 |
|---|---|
| author | Ozmen Istek Kevser Sokmen Erhan Cahit Ozcan Murat Tanrisever Turker Gelic Umit Koray Can Alihan Bozoglan Serkan Dundar |
| author_facet | Ozmen Istek Kevser Sokmen Erhan Cahit Ozcan Murat Tanrisever Turker Gelic Umit Koray Can Alihan Bozoglan Serkan Dundar |
| author_sort | Ozmen Istek |
| collection | DOAJ |
| description |
The aim of this study is to investigate the osseointegration levels of implants with different surfaces locally applied with enamel matrix protein by biomechanical methods. Thirty adult female Spraque Dawley rats weighing 300–350 g were included in the study as subjects. The rats were divided into 3 groups with 10 rats in each group: Machined Surface Group (n = 10), Sandblasted Large Acid Grid (SLA) Surface Group (n = 10) and Resorbable Blasting Material (RBM) Surface Group (n = 10). Titanium implants were surgically placed in the right tibias of the rats with sterile physiological serum cooling. Immediately before the implants were placed, local enamel matrix protein was applied to the prepared sockets and then the implants were placed. The rats were euthanized after waiting for osseointegration for four weeks and the implants were taken with the surrounding bone tissues after the soft tissues were removed. The bone–implant contact of all implants was analyzed by biomechanical method and recorded in Newton·cm-1 (N·cm-1). When the obtained biomechanical data were examined, the average bone–implant contact value was found to be 2.24 ± 0.67 (N·cm-1) in machined surface implants, 4.5 ± 1.36 (N·cm-1) in SLA surface implants and 3.24 ± 0.94 (N·cm-1) in RBM surface implants. A statistically difference was detected between machined surface implants and SLA surface implants (P<0.05; P=0.02). It can be stated that local enamel matrix protein application may increase bone–implant connection in SLA surface implants.
|
| format | Article |
| id | doaj-art-cae18fe5a6ef40df9c680fac95b78b3c |
| institution | DOAJ |
| issn | 0798-2259 2521-9715 |
| language | English |
| publishDate | 2025-05-01 |
| publisher | Universidad del Zulia |
| record_format | Article |
| series | Revista Científica |
| spelling | doaj-art-cae18fe5a6ef40df9c680fac95b78b3c2025-08-20T03:13:11ZengUniversidad del ZuliaRevista Científica0798-22592521-97152025-05-0135210.52973/rcfcv-e35625Effects of local enemal matrix protein on osseointegration of different surface Titanium implantsOzmen Istek0Kevser Sokmen1Erhan Cahit Ozcan2Murat Tanrisever3Turker Gelic4Umit Koray Can5Alihan Bozoglan6Serkan Dundar7Mus Alparslan University, Faculty of Health Sciences, Department of Nursing. Mus, Türkiye.Alanya Alaaddin Keykubat University, Faculty of Dentistry, Department of Periodontology. Antalya, Türkiye.Firat University, Faculty of Medicine, Department of Estetic, Plastic and Reconstructive Surgery. Elazig, Türkiye. Firat University, Faculty of Veterinary, Department of Surgery. Elazig, Türkiye.Firat University, Faculty of Veterinary, Department of Surgery. Elazig, Türkiye.Turkish Jockey Club. Elazig, Türkiye.Firat University, Faculty of Dentistry, Department of Periodontology. Elazig, Türkiye. Firat University, Faculty of Dentistry, Department of Periodontology. Elazig, Türkiye. The aim of this study is to investigate the osseointegration levels of implants with different surfaces locally applied with enamel matrix protein by biomechanical methods. Thirty adult female Spraque Dawley rats weighing 300–350 g were included in the study as subjects. The rats were divided into 3 groups with 10 rats in each group: Machined Surface Group (n = 10), Sandblasted Large Acid Grid (SLA) Surface Group (n = 10) and Resorbable Blasting Material (RBM) Surface Group (n = 10). Titanium implants were surgically placed in the right tibias of the rats with sterile physiological serum cooling. Immediately before the implants were placed, local enamel matrix protein was applied to the prepared sockets and then the implants were placed. The rats were euthanized after waiting for osseointegration for four weeks and the implants were taken with the surrounding bone tissues after the soft tissues were removed. The bone–implant contact of all implants was analyzed by biomechanical method and recorded in Newton·cm-1 (N·cm-1). When the obtained biomechanical data were examined, the average bone–implant contact value was found to be 2.24 ± 0.67 (N·cm-1) in machined surface implants, 4.5 ± 1.36 (N·cm-1) in SLA surface implants and 3.24 ± 0.94 (N·cm-1) in RBM surface implants. A statistically difference was detected between machined surface implants and SLA surface implants (P<0.05; P=0.02). It can be stated that local enamel matrix protein application may increase bone–implant connection in SLA surface implants. https://produccioncientificaluz.org/index.php/cientifica/article/view/43854Local enamel matrix proteintitanium implantosseointegrationbone implant connectionbone implant contact |
| spellingShingle | Ozmen Istek Kevser Sokmen Erhan Cahit Ozcan Murat Tanrisever Turker Gelic Umit Koray Can Alihan Bozoglan Serkan Dundar Effects of local enemal matrix protein on osseointegration of different surface Titanium implants Revista Científica Local enamel matrix protein titanium implant osseointegration bone implant connection bone implant contact |
| title | Effects of local enemal matrix protein on osseointegration of different surface Titanium implants |
| title_full | Effects of local enemal matrix protein on osseointegration of different surface Titanium implants |
| title_fullStr | Effects of local enemal matrix protein on osseointegration of different surface Titanium implants |
| title_full_unstemmed | Effects of local enemal matrix protein on osseointegration of different surface Titanium implants |
| title_short | Effects of local enemal matrix protein on osseointegration of different surface Titanium implants |
| title_sort | effects of local enemal matrix protein on osseointegration of different surface titanium implants |
| topic | Local enamel matrix protein titanium implant osseointegration bone implant connection bone implant contact |
| url | https://produccioncientificaluz.org/index.php/cientifica/article/view/43854 |
| work_keys_str_mv | AT ozmenistek effectsoflocalenemalmatrixproteinonosseointegrationofdifferentsurfacetitaniumimplants AT kevsersokmen effectsoflocalenemalmatrixproteinonosseointegrationofdifferentsurfacetitaniumimplants AT erhancahitozcan effectsoflocalenemalmatrixproteinonosseointegrationofdifferentsurfacetitaniumimplants AT murattanrisever effectsoflocalenemalmatrixproteinonosseointegrationofdifferentsurfacetitaniumimplants AT turkergelic effectsoflocalenemalmatrixproteinonosseointegrationofdifferentsurfacetitaniumimplants AT umitkoraycan effectsoflocalenemalmatrixproteinonosseointegrationofdifferentsurfacetitaniumimplants AT alihanbozoglan effectsoflocalenemalmatrixproteinonosseointegrationofdifferentsurfacetitaniumimplants AT serkandundar effectsoflocalenemalmatrixproteinonosseointegrationofdifferentsurfacetitaniumimplants |