Mathematical evaluation of hemolysis in a channel centrifugal blood pump

The objective of this work is to conduct research on a mathematical model to assess hemolytic characteristics in a channel centrifugal blood pump developed by us with 2000–3400 rpm impeller speed range and 100–250 mmHg pressure drop in different parts of the pump flow path. Hemolysis index was measu...

Full description

Saved in:
Bibliographic Details
Main Authors: A. P. Kuleshov, G. P. Itkin, A. S. Buchnev, A. A. Drobyshev
Format: Article
Language:Russian
Published: Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov 2020-10-01
Series:Вестник трансплантологии и искусственных органов
Subjects:
Online Access:https://journal.transpl.ru/vtio/article/view/1230
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849774733253410816
author A. P. Kuleshov
G. P. Itkin
A. S. Buchnev
A. A. Drobyshev
author_facet A. P. Kuleshov
G. P. Itkin
A. S. Buchnev
A. A. Drobyshev
author_sort A. P. Kuleshov
collection DOAJ
description The objective of this work is to conduct research on a mathematical model to assess hemolytic characteristics in a channel centrifugal blood pump developed by us with 2000–3400 rpm impeller speed range and 100–250 mmHg pressure drop in different parts of the pump flow path. Hemolysis index was measured at 1 to 10 L/min flow rate. The result was an estimate of the average magnitude of the shear stress (SS), taking into account the distribution in the pump, which ranged from 40 to 60 Pa. The most critical areas of the pump in terms of blood injury were evaluated. The maximum SSs were determined: 456 Pa in the impeller wheel zone and 533.3 Pa in the adjacent area of the body, with an exposure time of 0.0115 s and 0.0821 s respectively. In these zones, maximum hemolysis index values were 0.0420 and 0.0744 respectively. Based on the data obtained, these zones were optimized in terms of minimizing hemolysis.
format Article
id doaj-art-caa2269dbed9483b9fb1eaae53fde5e0
institution DOAJ
issn 1995-1191
language Russian
publishDate 2020-10-01
publisher Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
record_format Article
series Вестник трансплантологии и искусственных органов
spelling doaj-art-caa2269dbed9483b9fb1eaae53fde5e02025-08-20T03:01:38ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.ShumakovВестник трансплантологии и искусственных органов1995-11912020-10-01223798510.15825/1995-1191-2020-3-79-85898Mathematical evaluation of hemolysis in a channel centrifugal blood pumpA. P. Kuleshov0G. P. Itkin1A. S. Buchnev2A. A. Drobyshev3Shumakov National Medical Research Center of Transplantology and Artificial OrgansShumakov National Medical Research Center of Transplantology and Artificial Organs; Moscow Institute of Physics and TechnologyShumakov National Medical Research Center of Transplantology and Artificial OrgansShumakov National Medical Research Center of Transplantology and Artificial OrgansThe objective of this work is to conduct research on a mathematical model to assess hemolytic characteristics in a channel centrifugal blood pump developed by us with 2000–3400 rpm impeller speed range and 100–250 mmHg pressure drop in different parts of the pump flow path. Hemolysis index was measured at 1 to 10 L/min flow rate. The result was an estimate of the average magnitude of the shear stress (SS), taking into account the distribution in the pump, which ranged from 40 to 60 Pa. The most critical areas of the pump in terms of blood injury were evaluated. The maximum SSs were determined: 456 Pa in the impeller wheel zone and 533.3 Pa in the adjacent area of the body, with an exposure time of 0.0115 s and 0.0821 s respectively. In these zones, maximum hemolysis index values were 0.0420 and 0.0744 respectively. Based on the data obtained, these zones were optimized in terms of minimizing hemolysis.https://journal.transpl.ru/vtio/article/view/12303d modelingmechanical circulatory supportchannel centrifugal blood pumpshear stressexposure timehemolysis index
spellingShingle A. P. Kuleshov
G. P. Itkin
A. S. Buchnev
A. A. Drobyshev
Mathematical evaluation of hemolysis in a channel centrifugal blood pump
Вестник трансплантологии и искусственных органов
3d modeling
mechanical circulatory support
channel centrifugal blood pump
shear stress
exposure time
hemolysis index
title Mathematical evaluation of hemolysis in a channel centrifugal blood pump
title_full Mathematical evaluation of hemolysis in a channel centrifugal blood pump
title_fullStr Mathematical evaluation of hemolysis in a channel centrifugal blood pump
title_full_unstemmed Mathematical evaluation of hemolysis in a channel centrifugal blood pump
title_short Mathematical evaluation of hemolysis in a channel centrifugal blood pump
title_sort mathematical evaluation of hemolysis in a channel centrifugal blood pump
topic 3d modeling
mechanical circulatory support
channel centrifugal blood pump
shear stress
exposure time
hemolysis index
url https://journal.transpl.ru/vtio/article/view/1230
work_keys_str_mv AT apkuleshov mathematicalevaluationofhemolysisinachannelcentrifugalbloodpump
AT gpitkin mathematicalevaluationofhemolysisinachannelcentrifugalbloodpump
AT asbuchnev mathematicalevaluationofhemolysisinachannelcentrifugalbloodpump
AT aadrobyshev mathematicalevaluationofhemolysisinachannelcentrifugalbloodpump