Design and Construction of Sewage Structures Under High-Level Underground Water Conditions Using theTop-Down Method: A Case Study of Sewage Pumping Station PS2 in Dorood City

In this paper, various issues related to the design and construction of a pump station under high-level underground water conditions in Dorood City using different approaches are investigated. These methods include deep wells, sheet pile walls, and secant walls. By evaluating the deficiencies of the...

Full description

Saved in:
Bibliographic Details
Main Authors: Bahador Mirzaei, Abbas Pirayandeh, Hojjat Emami
Format: Article
Language:English
Published: Water and Wastewater Consulting Engineers Research Development 2024-08-01
Series:آب و فاضلاب
Subjects:
Online Access:https://www.wwjournal.ir/article_209265_a17b03af89ae63f906fa9ca4a226e8ed.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832575480322064384
author Bahador Mirzaei
Abbas Pirayandeh
Hojjat Emami
author_facet Bahador Mirzaei
Abbas Pirayandeh
Hojjat Emami
author_sort Bahador Mirzaei
collection DOAJ
description In this paper, various issues related to the design and construction of a pump station under high-level underground water conditions in Dorood City using different approaches are investigated. These methods include deep wells, sheet pile walls, and secant walls. By evaluating the deficiencies of these methods in dealing with high-level underground water conditions, a new approach called the Top-Down method is studied and introduced; it was previously presented for the construction of caissons and buildings. In comparison to other methods, the advantages and disadvantages of the Top-Down method are evaluated, leading to its selection; Subsequently, the problems, including the waterstop placement system and construction details were addressed and modified. Architectural and structural details for the construction of such structures applying the Top-Down method were then presented in the research. Finally, the efficiency and robustness of the proposed approach in the design and construction of concrete sewage structures exposed to high-level underground water, are demonstrated from the technical and economic perspectives, construction time, costs and safety level.
format Article
id doaj-art-ca48ad4b15044a068bc58db090d5d06c
institution Kabale University
issn 1024-5936
2383-0905
language English
publishDate 2024-08-01
publisher Water and Wastewater Consulting Engineers Research Development
record_format Article
series آب و فاضلاب
spelling doaj-art-ca48ad4b15044a068bc58db090d5d06c2025-02-01T07:44:57ZengWater and Wastewater Consulting Engineers Research Developmentآب و فاضلاب1024-59362383-09052024-08-01353254410.22093/wwj.2024.416237.3370209265Design and Construction of Sewage Structures Under High-Level Underground Water Conditions Using theTop-Down Method: A Case Study of Sewage Pumping Station PS2 in Dorood CityBahador Mirzaei0Abbas Pirayandeh1Hojjat Emami2Senior Structural Engineer and Project/Design Manager, Water and Wastewater Consulting Engineers, Isfahan, IranChief Executive Officer, Water and Wastewater Consulting Engineers, Isfahan, IranHead of Civil Engineering Design/Drafting Dept., Water and Wastewater Consulting Engineers, Isfahan, IranIn this paper, various issues related to the design and construction of a pump station under high-level underground water conditions in Dorood City using different approaches are investigated. These methods include deep wells, sheet pile walls, and secant walls. By evaluating the deficiencies of these methods in dealing with high-level underground water conditions, a new approach called the Top-Down method is studied and introduced; it was previously presented for the construction of caissons and buildings. In comparison to other methods, the advantages and disadvantages of the Top-Down method are evaluated, leading to its selection; Subsequently, the problems, including the waterstop placement system and construction details were addressed and modified. Architectural and structural details for the construction of such structures applying the Top-Down method were then presented in the research. Finally, the efficiency and robustness of the proposed approach in the design and construction of concrete sewage structures exposed to high-level underground water, are demonstrated from the technical and economic perspectives, construction time, costs and safety level.https://www.wwjournal.ir/article_209265_a17b03af89ae63f906fa9ca4a226e8ed.pdfpumping stationsewagetop-down methodhigh groundwater level
spellingShingle Bahador Mirzaei
Abbas Pirayandeh
Hojjat Emami
Design and Construction of Sewage Structures Under High-Level Underground Water Conditions Using theTop-Down Method: A Case Study of Sewage Pumping Station PS2 in Dorood City
آب و فاضلاب
pumping station
sewage
top-down method
high groundwater level
title Design and Construction of Sewage Structures Under High-Level Underground Water Conditions Using theTop-Down Method: A Case Study of Sewage Pumping Station PS2 in Dorood City
title_full Design and Construction of Sewage Structures Under High-Level Underground Water Conditions Using theTop-Down Method: A Case Study of Sewage Pumping Station PS2 in Dorood City
title_fullStr Design and Construction of Sewage Structures Under High-Level Underground Water Conditions Using theTop-Down Method: A Case Study of Sewage Pumping Station PS2 in Dorood City
title_full_unstemmed Design and Construction of Sewage Structures Under High-Level Underground Water Conditions Using theTop-Down Method: A Case Study of Sewage Pumping Station PS2 in Dorood City
title_short Design and Construction of Sewage Structures Under High-Level Underground Water Conditions Using theTop-Down Method: A Case Study of Sewage Pumping Station PS2 in Dorood City
title_sort design and construction of sewage structures under high level underground water conditions using thetop down method a case study of sewage pumping station ps2 in dorood city
topic pumping station
sewage
top-down method
high groundwater level
url https://www.wwjournal.ir/article_209265_a17b03af89ae63f906fa9ca4a226e8ed.pdf
work_keys_str_mv AT bahadormirzaei designandconstructionofsewagestructuresunderhighlevelundergroundwaterconditionsusingthetopdownmethodacasestudyofsewagepumpingstationps2indoroodcity
AT abbaspirayandeh designandconstructionofsewagestructuresunderhighlevelundergroundwaterconditionsusingthetopdownmethodacasestudyofsewagepumpingstationps2indoroodcity
AT hojjatemami designandconstructionofsewagestructuresunderhighlevelundergroundwaterconditionsusingthetopdownmethodacasestudyofsewagepumpingstationps2indoroodcity