Monte Carlo-based analysis of the photon beam fluence with air gap thickness between Linac head exit window and patient’s skin in radiotherapy treatments

Linear accelerators (Linac) are used in radiation therapy treatment and its technology improvement ensures high dosimetry quality that should be conserved for high radiotherapy efficiency. However, does the air gap between the exit window of Linac head and patient’s skin alters the physical properti...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamed Bencheikh, Abdelmajid Maghnouj, Jaouad Tajmouati
Format: Article
Language:English
Published: Institute for Nuclear Research, National Academy of Sciences of Ukraine 2020-09-01
Series:Ядерна фізика та енергетика
Subjects:
Online Access:http://jnpae.kinr.kiev.ua/21.3/Articles_PDF/jnpae-2020-21-0275-Bencheikh.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849682895856205824
author Mohamed Bencheikh
Abdelmajid Maghnouj
Jaouad Tajmouati
author_facet Mohamed Bencheikh
Abdelmajid Maghnouj
Jaouad Tajmouati
author_sort Mohamed Bencheikh
collection DOAJ
description Linear accelerators (Linac) are used in radiation therapy treatment and its technology improvement ensures high dosimetry quality that should be conserved for high radiotherapy efficiency. However, does the air gap between the exit window of Linac head and patient’s skin alters the physical properties of the photon beam? The objective of this study is to assess the physical properties changes of photon beam fluence according to air gap thickness under the Linac head. The air gap under the Linac head is the last material in the photon beam path; it induces alterations in the beam quality before reaching the patient’s skin. The Varian Clinac 2100 head and the air gap up to the phantom surface are modelled using Monte Carlo BEAMnrc code; the nominal beam energy is 6 MV. The BEAMDP code is used to extract the photon fluence. The photon beam fluence is affected by the air gap under Linac head and decreases by six times due to the photon beam attenuation with air gap thickness; in addition to increasing of beam contamination by scattered photons and electrons. Thus, the air gap induces the beam quality deterioration which is evaluated in terms of photon fluence with air gap thickness. To remove the particles contaminations and conserve integrally the photon beam quality, the number of the photon interactions with air atoms should be as low as possible under Linac head up to patient’s skin and ensure a higher quality of the radiotherapy treatment of deep tumour.
format Article
id doaj-art-c987f8e60df54ee5af9da6cde877dbc8
institution DOAJ
issn 1818-331X
2074-0565
language English
publishDate 2020-09-01
publisher Institute for Nuclear Research, National Academy of Sciences of Ukraine
record_format Article
series Ядерна фізика та енергетика
spelling doaj-art-c987f8e60df54ee5af9da6cde877dbc82025-08-20T03:24:03ZengInstitute for Nuclear Research, National Academy of Sciences of UkraineЯдерна фізика та енергетика1818-331X2074-05652020-09-01213275280https://doi.org/10.15407/jnpae2020.03.275Monte Carlo-based analysis of the photon beam fluence with air gap thickness between Linac head exit window and patient’s skin in radiotherapy treatmentsMohamed Bencheikh0Abdelmajid Maghnouj1Jaouad Tajmouati2Physics Department, Faculty of Sciences and Technologies Mohammedia, Hassan II University of Casablanca, Mohammedia, MoroccoLISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez, MoroccoLISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez, MoroccoLinear accelerators (Linac) are used in radiation therapy treatment and its technology improvement ensures high dosimetry quality that should be conserved for high radiotherapy efficiency. However, does the air gap between the exit window of Linac head and patient’s skin alters the physical properties of the photon beam? The objective of this study is to assess the physical properties changes of photon beam fluence according to air gap thickness under the Linac head. The air gap under the Linac head is the last material in the photon beam path; it induces alterations in the beam quality before reaching the patient’s skin. The Varian Clinac 2100 head and the air gap up to the phantom surface are modelled using Monte Carlo BEAMnrc code; the nominal beam energy is 6 MV. The BEAMDP code is used to extract the photon fluence. The photon beam fluence is affected by the air gap under Linac head and decreases by six times due to the photon beam attenuation with air gap thickness; in addition to increasing of beam contamination by scattered photons and electrons. Thus, the air gap induces the beam quality deterioration which is evaluated in terms of photon fluence with air gap thickness. To remove the particles contaminations and conserve integrally the photon beam quality, the number of the photon interactions with air atoms should be as low as possible under Linac head up to patient’s skin and ensure a higher quality of the radiotherapy treatment of deep tumour.http://jnpae.kinr.kiev.ua/21.3/Articles_PDF/jnpae-2020-21-0275-Bencheikh.pdfair gaplinac headmonte carlo simulationphoton beam qualitybeamnrc code.
spellingShingle Mohamed Bencheikh
Abdelmajid Maghnouj
Jaouad Tajmouati
Monte Carlo-based analysis of the photon beam fluence with air gap thickness between Linac head exit window and patient’s skin in radiotherapy treatments
Ядерна фізика та енергетика
air gap
linac head
monte carlo simulation
photon beam quality
beamnrc code.
title Monte Carlo-based analysis of the photon beam fluence with air gap thickness between Linac head exit window and patient’s skin in radiotherapy treatments
title_full Monte Carlo-based analysis of the photon beam fluence with air gap thickness between Linac head exit window and patient’s skin in radiotherapy treatments
title_fullStr Monte Carlo-based analysis of the photon beam fluence with air gap thickness between Linac head exit window and patient’s skin in radiotherapy treatments
title_full_unstemmed Monte Carlo-based analysis of the photon beam fluence with air gap thickness between Linac head exit window and patient’s skin in radiotherapy treatments
title_short Monte Carlo-based analysis of the photon beam fluence with air gap thickness between Linac head exit window and patient’s skin in radiotherapy treatments
title_sort monte carlo based analysis of the photon beam fluence with air gap thickness between linac head exit window and patient s skin in radiotherapy treatments
topic air gap
linac head
monte carlo simulation
photon beam quality
beamnrc code.
url http://jnpae.kinr.kiev.ua/21.3/Articles_PDF/jnpae-2020-21-0275-Bencheikh.pdf
work_keys_str_mv AT mohamedbencheikh montecarlobasedanalysisofthephotonbeamfluencewithairgapthicknessbetweenlinacheadexitwindowandpatientsskininradiotherapytreatments
AT abdelmajidmaghnouj montecarlobasedanalysisofthephotonbeamfluencewithairgapthicknessbetweenlinacheadexitwindowandpatientsskininradiotherapytreatments
AT jaouadtajmouati montecarlobasedanalysisofthephotonbeamfluencewithairgapthicknessbetweenlinacheadexitwindowandpatientsskininradiotherapytreatments