Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass Grafting
Background. Long-term graft patency is the major factor impacting survival after coronary artery bypass grafting. Arteries are superior in this regard. Radial artery is considered the second best conduit after internal mammary artery. Several studies have shown excellent radial artery patency. We ev...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2016-01-01
|
Series: | Cardiology Research and Practice |
Online Access: | http://dx.doi.org/10.1155/2016/8047340 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832561528453201920 |
---|---|
author | Om Prakash Yadava Vinod Sharma Arvind Prakash Vikas Ahlawat Anirban Kundu Bikram K. Mohanty Rekha Mishra Amit K. Dinda |
author_facet | Om Prakash Yadava Vinod Sharma Arvind Prakash Vikas Ahlawat Anirban Kundu Bikram K. Mohanty Rekha Mishra Amit K. Dinda |
author_sort | Om Prakash Yadava |
collection | DOAJ |
description | Background. Long-term graft patency is the major factor impacting survival after coronary artery bypass grafting. Arteries are superior in this regard. Radial artery is considered the second best conduit after internal mammary artery. Several studies have shown excellent radial artery patency. We evaluated the morphologic characteristics of radial artery by three modalities, (i) preoperative Doppler ultrasound, (ii) intraoperative manual morphometry, and (iii) postoperative histology-based morphometry, and compared these with the aim of validating Doppler as a noninvasive test of choice for preoperative assessment of radial artery. Methods. This was a prospective study involving 100 patients undergoing coronary artery bypass grafting in which radial artery was used. The radial artery was assessed using preoperative Doppler ultrasound studies, intraoperative morphometry, and postoperative histopathology and morphometry. The morphometric measurements included (i) luminal diameter, (ii) intimal and medial thickness, and (iii) intima-media thickness ratio. Results. Using Bland-Altman plots, there was a 95% limit of agreement between the preoperative Doppler measurements and the postoperative histopathology and morphometry. Conclusion. Doppler ultrasound is an accurate screening test for evaluation of radial artery, in terms of intimal/medial thickness and luminal diameter as a conduit in coronary artery bypass grafting and has been validated by both morphometric and histopathology based studies. |
format | Article |
id | doaj-art-c8653cb16b6547e0be8880e69403c64b |
institution | Kabale University |
issn | 2090-8016 2090-0597 |
language | English |
publishDate | 2016-01-01 |
publisher | Wiley |
record_format | Article |
series | Cardiology Research and Practice |
spelling | doaj-art-c8653cb16b6547e0be8880e69403c64b2025-02-03T01:24:55ZengWileyCardiology Research and Practice2090-80162090-05972016-01-01201610.1155/2016/80473408047340Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass GraftingOm Prakash Yadava0Vinod Sharma1Arvind Prakash2Vikas Ahlawat3Anirban Kundu4Bikram K. Mohanty5Rekha Mishra6Amit K. Dinda7Department of Cardiothoracic Surgery, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, IndiaDepartment of Cardiology, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, IndiaDepartment of Cardiac Anesthesiology, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, IndiaDepartment of Cardiothoracic Surgery, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, IndiaDepartment of Cardiothoracic Surgery, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, IndiaDepartment of Cardiothoracic Surgery, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, IndiaDepartment of Cardiology, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, IndiaDepartment of Pathology, All India Institute of Medical Sciences, New Delhi 110029, IndiaBackground. Long-term graft patency is the major factor impacting survival after coronary artery bypass grafting. Arteries are superior in this regard. Radial artery is considered the second best conduit after internal mammary artery. Several studies have shown excellent radial artery patency. We evaluated the morphologic characteristics of radial artery by three modalities, (i) preoperative Doppler ultrasound, (ii) intraoperative manual morphometry, and (iii) postoperative histology-based morphometry, and compared these with the aim of validating Doppler as a noninvasive test of choice for preoperative assessment of radial artery. Methods. This was a prospective study involving 100 patients undergoing coronary artery bypass grafting in which radial artery was used. The radial artery was assessed using preoperative Doppler ultrasound studies, intraoperative morphometry, and postoperative histopathology and morphometry. The morphometric measurements included (i) luminal diameter, (ii) intimal and medial thickness, and (iii) intima-media thickness ratio. Results. Using Bland-Altman plots, there was a 95% limit of agreement between the preoperative Doppler measurements and the postoperative histopathology and morphometry. Conclusion. Doppler ultrasound is an accurate screening test for evaluation of radial artery, in terms of intimal/medial thickness and luminal diameter as a conduit in coronary artery bypass grafting and has been validated by both morphometric and histopathology based studies.http://dx.doi.org/10.1155/2016/8047340 |
spellingShingle | Om Prakash Yadava Vinod Sharma Arvind Prakash Vikas Ahlawat Anirban Kundu Bikram K. Mohanty Rekha Mishra Amit K. Dinda Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass Grafting Cardiology Research and Practice |
title | Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass Grafting |
title_full | Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass Grafting |
title_fullStr | Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass Grafting |
title_full_unstemmed | Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass Grafting |
title_short | Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass Grafting |
title_sort | correlation between doppler manual morphometry and histopathology based morphometry of radial artery as a conduit in coronary artery bypass grafting |
url | http://dx.doi.org/10.1155/2016/8047340 |
work_keys_str_mv | AT omprakashyadava correlationbetweendopplermanualmorphometryandhistopathologybasedmorphometryofradialarteryasaconduitincoronaryarterybypassgrafting AT vinodsharma correlationbetweendopplermanualmorphometryandhistopathologybasedmorphometryofradialarteryasaconduitincoronaryarterybypassgrafting AT arvindprakash correlationbetweendopplermanualmorphometryandhistopathologybasedmorphometryofradialarteryasaconduitincoronaryarterybypassgrafting AT vikasahlawat correlationbetweendopplermanualmorphometryandhistopathologybasedmorphometryofradialarteryasaconduitincoronaryarterybypassgrafting AT anirbankundu correlationbetweendopplermanualmorphometryandhistopathologybasedmorphometryofradialarteryasaconduitincoronaryarterybypassgrafting AT bikramkmohanty correlationbetweendopplermanualmorphometryandhistopathologybasedmorphometryofradialarteryasaconduitincoronaryarterybypassgrafting AT rekhamishra correlationbetweendopplermanualmorphometryandhistopathologybasedmorphometryofradialarteryasaconduitincoronaryarterybypassgrafting AT amitkdinda correlationbetweendopplermanualmorphometryandhistopathologybasedmorphometryofradialarteryasaconduitincoronaryarterybypassgrafting |