Comparative Assessment of Rapid Identification and Antimicrobial Susceptibility Testing Methods for Bloodstream Infections in a Non-24/7 Clinical Microbiology Laboratory

Rapid identification and antimicrobial susceptibility testing are essential for timely bloodstream infection (BSI) management. This study aimed to investigate the performance and turnaround time of multiple rapid diagnostic methods in a microbiology laboratory without 24/7 operation. This study incl...

Full description

Saved in:
Bibliographic Details
Main Authors: Sunggyun Park, Dohoon Kim, Namhee Ryoo
Format: Article
Language:English
Published: MDPI AG 2025-04-01
Series:Microorganisms
Subjects:
Online Access:https://www.mdpi.com/2076-2607/13/5/1041
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850256152023007232
author Sunggyun Park
Dohoon Kim
Namhee Ryoo
author_facet Sunggyun Park
Dohoon Kim
Namhee Ryoo
author_sort Sunggyun Park
collection DOAJ
description Rapid identification and antimicrobial susceptibility testing are essential for timely bloodstream infection (BSI) management. This study aimed to investigate the performance and turnaround time of multiple rapid diagnostic methods in a microbiology laboratory without 24/7 operation. This study included 236 positive blood culture bottles. Rapid identification methods were assessed with the SepsiTyper kit and the FilmArray blood culture identification 2 (BCID2) panel. Rapid antimicrobial susceptibility testing (AST) methods involved direct AST using the BD Phoenix M50 system and QuantaMatrix direct and rapid antimicrobial susceptibility testing (dRAST) and resistance gene detection with the FilmArray BCID2 panel. Conventional methods were used to compare results. The turnaround time was analyzed from blood culture positivity to preparation initiation and from preparation initiation to result reporting. Both rapid identification methods significantly reduced the turnaround time (~1 day and 19 h) compared to conventional identification. SepsiTyper demonstrated higher species-level accuracy in monomicrobial samples, whereas BCID2 outperformed in polymicrobial cases. Among the rapid AST methods, BCID2 and dRAST enabled result reporting within 24 h of positivity. Preparation delays were >45% of the overall turnaround time. Rapid diagnostics substantially shortened the BSI diagnostic time, even in limited-operation settings. Their clinical utility may be improved through 24/7 laboratory workflows.
format Article
id doaj-art-c6e29498b75a4daab1f0dbb3dda096f4
institution OA Journals
issn 2076-2607
language English
publishDate 2025-04-01
publisher MDPI AG
record_format Article
series Microorganisms
spelling doaj-art-c6e29498b75a4daab1f0dbb3dda096f42025-08-20T01:56:42ZengMDPI AGMicroorganisms2076-26072025-04-01135104110.3390/microorganisms13051041Comparative Assessment of Rapid Identification and Antimicrobial Susceptibility Testing Methods for Bloodstream Infections in a Non-24/7 Clinical Microbiology LaboratorySunggyun Park0Dohoon Kim1Namhee Ryoo2Department of Laboratory Medicine, Keimyung University School of Medicine, Daegu 42601, Republic of KoreaDepartment of Laboratory Medicine, Keimyung University School of Medicine, Daegu 42601, Republic of KoreaDepartment of Laboratory Medicine, Keimyung University School of Medicine, Daegu 42601, Republic of KoreaRapid identification and antimicrobial susceptibility testing are essential for timely bloodstream infection (BSI) management. This study aimed to investigate the performance and turnaround time of multiple rapid diagnostic methods in a microbiology laboratory without 24/7 operation. This study included 236 positive blood culture bottles. Rapid identification methods were assessed with the SepsiTyper kit and the FilmArray blood culture identification 2 (BCID2) panel. Rapid antimicrobial susceptibility testing (AST) methods involved direct AST using the BD Phoenix M50 system and QuantaMatrix direct and rapid antimicrobial susceptibility testing (dRAST) and resistance gene detection with the FilmArray BCID2 panel. Conventional methods were used to compare results. The turnaround time was analyzed from blood culture positivity to preparation initiation and from preparation initiation to result reporting. Both rapid identification methods significantly reduced the turnaround time (~1 day and 19 h) compared to conventional identification. SepsiTyper demonstrated higher species-level accuracy in monomicrobial samples, whereas BCID2 outperformed in polymicrobial cases. Among the rapid AST methods, BCID2 and dRAST enabled result reporting within 24 h of positivity. Preparation delays were >45% of the overall turnaround time. Rapid diagnostics substantially shortened the BSI diagnostic time, even in limited-operation settings. Their clinical utility may be improved through 24/7 laboratory workflows.https://www.mdpi.com/2076-2607/13/5/1041bloodstream infectionantimicrobial susceptibility testingturnaround timenon-24/7 microbiology laboratory
spellingShingle Sunggyun Park
Dohoon Kim
Namhee Ryoo
Comparative Assessment of Rapid Identification and Antimicrobial Susceptibility Testing Methods for Bloodstream Infections in a Non-24/7 Clinical Microbiology Laboratory
Microorganisms
bloodstream infection
antimicrobial susceptibility testing
turnaround time
non-24/7 microbiology laboratory
title Comparative Assessment of Rapid Identification and Antimicrobial Susceptibility Testing Methods for Bloodstream Infections in a Non-24/7 Clinical Microbiology Laboratory
title_full Comparative Assessment of Rapid Identification and Antimicrobial Susceptibility Testing Methods for Bloodstream Infections in a Non-24/7 Clinical Microbiology Laboratory
title_fullStr Comparative Assessment of Rapid Identification and Antimicrobial Susceptibility Testing Methods for Bloodstream Infections in a Non-24/7 Clinical Microbiology Laboratory
title_full_unstemmed Comparative Assessment of Rapid Identification and Antimicrobial Susceptibility Testing Methods for Bloodstream Infections in a Non-24/7 Clinical Microbiology Laboratory
title_short Comparative Assessment of Rapid Identification and Antimicrobial Susceptibility Testing Methods for Bloodstream Infections in a Non-24/7 Clinical Microbiology Laboratory
title_sort comparative assessment of rapid identification and antimicrobial susceptibility testing methods for bloodstream infections in a non 24 7 clinical microbiology laboratory
topic bloodstream infection
antimicrobial susceptibility testing
turnaround time
non-24/7 microbiology laboratory
url https://www.mdpi.com/2076-2607/13/5/1041
work_keys_str_mv AT sunggyunpark comparativeassessmentofrapididentificationandantimicrobialsusceptibilitytestingmethodsforbloodstreaminfectionsinanon247clinicalmicrobiologylaboratory
AT dohoonkim comparativeassessmentofrapididentificationandantimicrobialsusceptibilitytestingmethodsforbloodstreaminfectionsinanon247clinicalmicrobiologylaboratory
AT namheeryoo comparativeassessmentofrapididentificationandantimicrobialsusceptibilitytestingmethodsforbloodstreaminfectionsinanon247clinicalmicrobiologylaboratory