Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time Domain

Modern electro-optical instruments are typically designed with assemblies of optomechanical members that support optics such that alignment is maintained in service environments that include random vibration loads. This paper presents a nonlinear numerical analysis that calculates statistics for the...

Full description

Saved in:
Bibliographic Details
Main Authors: Jeremy A. Palmer, Thomas L. Paez
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:Shock and Vibration
Online Access:http://dx.doi.org/10.3233/SAV-2010-0595
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849684859027456000
author Jeremy A. Palmer
Thomas L. Paez
author_facet Jeremy A. Palmer
Thomas L. Paez
author_sort Jeremy A. Palmer
collection DOAJ
description Modern electro-optical instruments are typically designed with assemblies of optomechanical members that support optics such that alignment is maintained in service environments that include random vibration loads. This paper presents a nonlinear numerical analysis that calculates statistics for the peak lateral response of optics in an optomechanical sub-assembly subject to random excitation of the housing. The work is unique in that the prior art does not address peak response probability distribution for stationary random vibration in the time domain for a common lens-retainer-housing system with Coulomb damping. Analytical results are validated by using displacement response data from random vibration testing of representative prototype sub-assemblies. A comparison of predictions to experimental results yields reasonable agreement. The Type I Asymptotic form provides the cumulative distribution function for peak response probabilities. Probabilities are calculated for actual lens centration tolerances. The probability that peak response will not exceed the centration tolerance is greater than 80% for prototype configurations where the tolerance is high (on the order of 30 micrometers). Conversely, the probability is low for those where the tolerance is less than 20 micrometers. The analysis suggests a design paradigm based on the influence of lateral stiffness on the magnitude of the response.
format Article
id doaj-art-c6a5c3a57eaa4fa1a76f74614cb47644
institution DOAJ
issn 1070-9622
1875-9203
language English
publishDate 2011-01-01
publisher Wiley
record_format Article
series Shock and Vibration
spelling doaj-art-c6a5c3a57eaa4fa1a76f74614cb476442025-08-20T03:23:19ZengWileyShock and Vibration1070-96221875-92032011-01-0118574775810.3233/SAV-2010-0595Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time DomainJeremy A. Palmer0Thomas L. Paez1Sandia National Laboratories, P.O. Box 5800, MS 01304, Albuquerque, NM, USAThomas Paez Consulting, 175 Iron King, Durango, CO, USAModern electro-optical instruments are typically designed with assemblies of optomechanical members that support optics such that alignment is maintained in service environments that include random vibration loads. This paper presents a nonlinear numerical analysis that calculates statistics for the peak lateral response of optics in an optomechanical sub-assembly subject to random excitation of the housing. The work is unique in that the prior art does not address peak response probability distribution for stationary random vibration in the time domain for a common lens-retainer-housing system with Coulomb damping. Analytical results are validated by using displacement response data from random vibration testing of representative prototype sub-assemblies. A comparison of predictions to experimental results yields reasonable agreement. The Type I Asymptotic form provides the cumulative distribution function for peak response probabilities. Probabilities are calculated for actual lens centration tolerances. The probability that peak response will not exceed the centration tolerance is greater than 80% for prototype configurations where the tolerance is high (on the order of 30 micrometers). Conversely, the probability is low for those where the tolerance is less than 20 micrometers. The analysis suggests a design paradigm based on the influence of lateral stiffness on the magnitude of the response.http://dx.doi.org/10.3233/SAV-2010-0595
spellingShingle Jeremy A. Palmer
Thomas L. Paez
Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time Domain
Shock and Vibration
title Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time Domain
title_full Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time Domain
title_fullStr Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time Domain
title_full_unstemmed Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time Domain
title_short Dynamic Response of an Optomechanical System to a Stationary Random Excitation in the Time Domain
title_sort dynamic response of an optomechanical system to a stationary random excitation in the time domain
url http://dx.doi.org/10.3233/SAV-2010-0595
work_keys_str_mv AT jeremyapalmer dynamicresponseofanoptomechanicalsystemtoastationaryrandomexcitationinthetimedomain
AT thomaslpaez dynamicresponseofanoptomechanicalsystemtoastationaryrandomexcitationinthetimedomain