Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study

It is a fact that contamination of EEG by ocular artifacts reduces the classification accuracy of a brain-computer interface (BCI) and diagnosis of brain diseases in clinical research. Therefore, for BCI and clinical applications, it is very important to remove/reduce these artifacts before EEG sign...

Full description

Saved in:
Bibliographic Details
Main Authors: Malik M. Naeem Mannan, M. Ahmad Kamran, Shinil Kang, Myung Yung Jeong
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Complexity
Online Access:http://dx.doi.org/10.1155/2018/4853741
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832560900345692160
author Malik M. Naeem Mannan
M. Ahmad Kamran
Shinil Kang
Myung Yung Jeong
author_facet Malik M. Naeem Mannan
M. Ahmad Kamran
Shinil Kang
Myung Yung Jeong
author_sort Malik M. Naeem Mannan
collection DOAJ
description It is a fact that contamination of EEG by ocular artifacts reduces the classification accuracy of a brain-computer interface (BCI) and diagnosis of brain diseases in clinical research. Therefore, for BCI and clinical applications, it is very important to remove/reduce these artifacts before EEG signal analysis. Although, EOG-based methods are simple and fast for removing artifacts but their performance, meanwhile, is highly affected by the bidirectional contamination process. Some studies emphasized that the solution to this problem is low-pass filtering EOG signals before using them in artifact removal algorithm but there is still no evidence on the optimal low-pass frequency limits of EOG signals. In this study, we investigated the optimal EOG signal filtering limits using state-of-the-art artifact removal techniques with fifteen artificially contaminated EEG and EOG datasets. In this comprehensive analysis, unfiltered and twelve different low-pass filtering of EOG signals were used with five different algorithms, namely, simple regression, least mean squares, recursive least squares, REGICA, and AIR. Results from statistical testing of time and frequency domain metrics suggested that a low-pass frequency between 6 and 8 Hz could be used as the most optimal filtering frequency of EOG signals, both to maximally overcome/minimize the effect of bidirectional contamination and to achieve good results from artifact removal algorithms. Furthermore, we also used BCI competition IV datasets to show the efficacy of the proposed framework on real EEG signals. The motor-imagery-based BCI achieved statistically significant high-classification accuracies when artifacts from EEG were removed by using 7 Hz low-pass filtering as compared to all other filterings of EOG signals. These results also validated our hypothesis that low-pass filtering should be applied to EOG signals for enhancing the performance of each algorithm before using them for artifact removal process. Moreover, the comparison results indicated that the hybrid algorithms outperformed the performance of single algorithms for both simulated and experimental EEG datasets.
format Article
id doaj-art-c675d068daef4180b7b5af18c1566dfc
institution Kabale University
issn 1076-2787
1099-0526
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Complexity
spelling doaj-art-c675d068daef4180b7b5af18c1566dfc2025-02-03T01:26:28ZengWileyComplexity1076-27871099-05262018-01-01201810.1155/2018/48537414853741Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive StudyMalik M. Naeem Mannan0M. Ahmad Kamran1Shinil Kang2Myung Yung Jeong3Department of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro 63beon-gil Geumjeong-gu, Busan 609-735, Republic of KoreaDepartment of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro 63beon-gil Geumjeong-gu, Busan 609-735, Republic of KoreaNational Center for Optically-Assisted Ultrahigh-precision Mechanical Systems, Yonsei University, Seoul 03722, Republic of KoreaDepartment of Cogno-Mechatronics Engineering, Pusan National University, 2 Busandaehak-ro 63beon-gil Geumjeong-gu, Busan 609-735, Republic of KoreaIt is a fact that contamination of EEG by ocular artifacts reduces the classification accuracy of a brain-computer interface (BCI) and diagnosis of brain diseases in clinical research. Therefore, for BCI and clinical applications, it is very important to remove/reduce these artifacts before EEG signal analysis. Although, EOG-based methods are simple and fast for removing artifacts but their performance, meanwhile, is highly affected by the bidirectional contamination process. Some studies emphasized that the solution to this problem is low-pass filtering EOG signals before using them in artifact removal algorithm but there is still no evidence on the optimal low-pass frequency limits of EOG signals. In this study, we investigated the optimal EOG signal filtering limits using state-of-the-art artifact removal techniques with fifteen artificially contaminated EEG and EOG datasets. In this comprehensive analysis, unfiltered and twelve different low-pass filtering of EOG signals were used with five different algorithms, namely, simple regression, least mean squares, recursive least squares, REGICA, and AIR. Results from statistical testing of time and frequency domain metrics suggested that a low-pass frequency between 6 and 8 Hz could be used as the most optimal filtering frequency of EOG signals, both to maximally overcome/minimize the effect of bidirectional contamination and to achieve good results from artifact removal algorithms. Furthermore, we also used BCI competition IV datasets to show the efficacy of the proposed framework on real EEG signals. The motor-imagery-based BCI achieved statistically significant high-classification accuracies when artifacts from EEG were removed by using 7 Hz low-pass filtering as compared to all other filterings of EOG signals. These results also validated our hypothesis that low-pass filtering should be applied to EOG signals for enhancing the performance of each algorithm before using them for artifact removal process. Moreover, the comparison results indicated that the hybrid algorithms outperformed the performance of single algorithms for both simulated and experimental EEG datasets.http://dx.doi.org/10.1155/2018/4853741
spellingShingle Malik M. Naeem Mannan
M. Ahmad Kamran
Shinil Kang
Myung Yung Jeong
Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study
Complexity
title Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study
title_full Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study
title_fullStr Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study
title_full_unstemmed Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study
title_short Effect of EOG Signal Filtering on the Removal of Ocular Artifacts and EEG-Based Brain-Computer Interface: A Comprehensive Study
title_sort effect of eog signal filtering on the removal of ocular artifacts and eeg based brain computer interface a comprehensive study
url http://dx.doi.org/10.1155/2018/4853741
work_keys_str_mv AT malikmnaeemmannan effectofeogsignalfilteringontheremovalofocularartifactsandeegbasedbraincomputerinterfaceacomprehensivestudy
AT mahmadkamran effectofeogsignalfilteringontheremovalofocularartifactsandeegbasedbraincomputerinterfaceacomprehensivestudy
AT shinilkang effectofeogsignalfilteringontheremovalofocularartifactsandeegbasedbraincomputerinterfaceacomprehensivestudy
AT myungyungjeong effectofeogsignalfilteringontheremovalofocularartifactsandeegbasedbraincomputerinterfaceacomprehensivestudy