Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor
A theoretical investigation on the thermal hydraulic characteristics of a new type of passive residual heat removal system (PRHRS), which is connected to the reactor coolant system via the secondary side of the steam generator, for an integral pressurized water reactor is presented in this paper. Th...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2009-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2009/473795 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832555563321393152 |
---|---|
author | Junli Gou Suizheng Qiu Guanghui Su Douna Jia |
author_facet | Junli Gou Suizheng Qiu Guanghui Su Douna Jia |
author_sort | Junli Gou |
collection | DOAJ |
description | A theoretical investigation on the thermal hydraulic characteristics of a new type of passive residual heat removal system (PRHRS), which is connected to the reactor coolant system via the secondary side of the steam generator, for an integral pressurized water reactor is presented in this paper. Three-interknited natural circulation loops are adopted by this PRHRS to remove the residual heat of the reactor core after a reactor trip. Based on the one-dimensional model and a simulation code (SCPRHRS), the transient behaviors of the PRHRS as well as the effects of the height difference between the steam generator and the heat exchanger and the heat transfer area of the heat exchanger are studied in detail. Through the calculation analysis, it is found that the calculated parameter variation trends are reasonable. The higher height difference between the steam generator and the residual heat exchanger and the larger heat transfer area of the residual heat exchanger are favorable to the passive residual heat removal system. |
format | Article |
id | doaj-art-c6269bbf61eb4af6b5516c9f22df7d83 |
institution | Kabale University |
issn | 1687-6075 1687-6083 |
language | English |
publishDate | 2009-01-01 |
publisher | Wiley |
record_format | Article |
series | Science and Technology of Nuclear Installations |
spelling | doaj-art-c6269bbf61eb4af6b5516c9f22df7d832025-02-03T05:47:52ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832009-01-01200910.1155/2009/473795473795Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water ReactorJunli Gou0Suizheng Qiu1Guanghui Su2Douna Jia3Department of Nuclear Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, ChinaDepartment of Nuclear Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, ChinaDepartment of Nuclear Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, ChinaDepartment of Nuclear Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, ChinaA theoretical investigation on the thermal hydraulic characteristics of a new type of passive residual heat removal system (PRHRS), which is connected to the reactor coolant system via the secondary side of the steam generator, for an integral pressurized water reactor is presented in this paper. Three-interknited natural circulation loops are adopted by this PRHRS to remove the residual heat of the reactor core after a reactor trip. Based on the one-dimensional model and a simulation code (SCPRHRS), the transient behaviors of the PRHRS as well as the effects of the height difference between the steam generator and the heat exchanger and the heat transfer area of the heat exchanger are studied in detail. Through the calculation analysis, it is found that the calculated parameter variation trends are reasonable. The higher height difference between the steam generator and the residual heat exchanger and the larger heat transfer area of the residual heat exchanger are favorable to the passive residual heat removal system.http://dx.doi.org/10.1155/2009/473795 |
spellingShingle | Junli Gou Suizheng Qiu Guanghui Su Douna Jia Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor Science and Technology of Nuclear Installations |
title | Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor |
title_full | Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor |
title_fullStr | Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor |
title_full_unstemmed | Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor |
title_short | Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor |
title_sort | thermal hydraulic analysis of a passive residual heat removal system for an integral pressurized water reactor |
url | http://dx.doi.org/10.1155/2009/473795 |
work_keys_str_mv | AT junligou thermalhydraulicanalysisofapassiveresidualheatremovalsystemforanintegralpressurizedwaterreactor AT suizhengqiu thermalhydraulicanalysisofapassiveresidualheatremovalsystemforanintegralpressurizedwaterreactor AT guanghuisu thermalhydraulicanalysisofapassiveresidualheatremovalsystemforanintegralpressurizedwaterreactor AT dounajia thermalhydraulicanalysisofapassiveresidualheatremovalsystemforanintegralpressurizedwaterreactor |