Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor

A theoretical investigation on the thermal hydraulic characteristics of a new type of passive residual heat removal system (PRHRS), which is connected to the reactor coolant system via the secondary side of the steam generator, for an integral pressurized water reactor is presented in this paper. Th...

Full description

Saved in:
Bibliographic Details
Main Authors: Junli Gou, Suizheng Qiu, Guanghui Su, Douna Jia
Format: Article
Language:English
Published: Wiley 2009-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2009/473795
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832555563321393152
author Junli Gou
Suizheng Qiu
Guanghui Su
Douna Jia
author_facet Junli Gou
Suizheng Qiu
Guanghui Su
Douna Jia
author_sort Junli Gou
collection DOAJ
description A theoretical investigation on the thermal hydraulic characteristics of a new type of passive residual heat removal system (PRHRS), which is connected to the reactor coolant system via the secondary side of the steam generator, for an integral pressurized water reactor is presented in this paper. Three-interknited natural circulation loops are adopted by this PRHRS to remove the residual heat of the reactor core after a reactor trip. Based on the one-dimensional model and a simulation code (SCPRHRS), the transient behaviors of the PRHRS as well as the effects of the height difference between the steam generator and the heat exchanger and the heat transfer area of the heat exchanger are studied in detail. Through the calculation analysis, it is found that the calculated parameter variation trends are reasonable. The higher height difference between the steam generator and the residual heat exchanger and the larger heat transfer area of the residual heat exchanger are favorable to the passive residual heat removal system.
format Article
id doaj-art-c6269bbf61eb4af6b5516c9f22df7d83
institution Kabale University
issn 1687-6075
1687-6083
language English
publishDate 2009-01-01
publisher Wiley
record_format Article
series Science and Technology of Nuclear Installations
spelling doaj-art-c6269bbf61eb4af6b5516c9f22df7d832025-02-03T05:47:52ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832009-01-01200910.1155/2009/473795473795Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water ReactorJunli Gou0Suizheng Qiu1Guanghui Su2Douna Jia3Department of Nuclear Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, ChinaDepartment of Nuclear Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, ChinaDepartment of Nuclear Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, ChinaDepartment of Nuclear Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, ChinaA theoretical investigation on the thermal hydraulic characteristics of a new type of passive residual heat removal system (PRHRS), which is connected to the reactor coolant system via the secondary side of the steam generator, for an integral pressurized water reactor is presented in this paper. Three-interknited natural circulation loops are adopted by this PRHRS to remove the residual heat of the reactor core after a reactor trip. Based on the one-dimensional model and a simulation code (SCPRHRS), the transient behaviors of the PRHRS as well as the effects of the height difference between the steam generator and the heat exchanger and the heat transfer area of the heat exchanger are studied in detail. Through the calculation analysis, it is found that the calculated parameter variation trends are reasonable. The higher height difference between the steam generator and the residual heat exchanger and the larger heat transfer area of the residual heat exchanger are favorable to the passive residual heat removal system.http://dx.doi.org/10.1155/2009/473795
spellingShingle Junli Gou
Suizheng Qiu
Guanghui Su
Douna Jia
Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor
Science and Technology of Nuclear Installations
title Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor
title_full Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor
title_fullStr Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor
title_full_unstemmed Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor
title_short Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor
title_sort thermal hydraulic analysis of a passive residual heat removal system for an integral pressurized water reactor
url http://dx.doi.org/10.1155/2009/473795
work_keys_str_mv AT junligou thermalhydraulicanalysisofapassiveresidualheatremovalsystemforanintegralpressurizedwaterreactor
AT suizhengqiu thermalhydraulicanalysisofapassiveresidualheatremovalsystemforanintegralpressurizedwaterreactor
AT guanghuisu thermalhydraulicanalysisofapassiveresidualheatremovalsystemforanintegralpressurizedwaterreactor
AT dounajia thermalhydraulicanalysisofapassiveresidualheatremovalsystemforanintegralpressurizedwaterreactor