Higher Reliability of Electric Power Supply under Wind Electrical Installation Operation in General Power System by Optimization of Their Scheduled Control Period
The paper considers reliability criteria characterizing wind electrical installations (WEI) as restorable systems. It has been shown that the main criterion influencing on reliability of WEI electric supply is a restoration time. Evaluation of restoration time influence on WEI control time has been...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2010-06-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Online Access: | https://energy.bntu.by/jour/article/view/422 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832557261124272128 |
---|---|
author | Y. A. Rolik A. V. Gornostay |
author_facet | Y. A. Rolik A. V. Gornostay |
author_sort | Y. A. Rolik |
collection | DOAJ |
description | The paper considers reliability criteria characterizing wind electrical installations (WEI) as restorable systems. It has been shown that the main criterion influencing on reliability of WEI electric supply is a restoration time. Evaluation of restoration time influence on WEI control time has been made in the paper. The paper presents methodology for determination of optimum period of WEI control. The optimum period of the scheduled control for WEI of NORDEX-type No.54 has been determined in the paper. |
format | Article |
id | doaj-art-c5bb84e4c119490f88f8d3a13a4e8406 |
institution | Kabale University |
issn | 1029-7448 2414-0341 |
language | Russian |
publishDate | 2010-06-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
spelling | doaj-art-c5bb84e4c119490f88f8d3a13a4e84062025-02-03T05:35:48ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412010-06-01033341415Higher Reliability of Electric Power Supply under Wind Electrical Installation Operation in General Power System by Optimization of Their Scheduled Control PeriodY. A. Rolik0A. V. Gornostay1Transport and Telecommunication InstituteBelarusian National Technical UniversityThe paper considers reliability criteria characterizing wind electrical installations (WEI) as restorable systems. It has been shown that the main criterion influencing on reliability of WEI electric supply is a restoration time. Evaluation of restoration time influence on WEI control time has been made in the paper. The paper presents methodology for determination of optimum period of WEI control. The optimum period of the scheduled control for WEI of NORDEX-type No.54 has been determined in the paper.https://energy.bntu.by/jour/article/view/422 |
spellingShingle | Y. A. Rolik A. V. Gornostay Higher Reliability of Electric Power Supply under Wind Electrical Installation Operation in General Power System by Optimization of Their Scheduled Control Period Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
title | Higher Reliability of Electric Power Supply under Wind Electrical Installation Operation in General Power System by Optimization of Their Scheduled Control Period |
title_full | Higher Reliability of Electric Power Supply under Wind Electrical Installation Operation in General Power System by Optimization of Their Scheduled Control Period |
title_fullStr | Higher Reliability of Electric Power Supply under Wind Electrical Installation Operation in General Power System by Optimization of Their Scheduled Control Period |
title_full_unstemmed | Higher Reliability of Electric Power Supply under Wind Electrical Installation Operation in General Power System by Optimization of Their Scheduled Control Period |
title_short | Higher Reliability of Electric Power Supply under Wind Electrical Installation Operation in General Power System by Optimization of Their Scheduled Control Period |
title_sort | higher reliability of electric power supply under wind electrical installation operation in general power system by optimization of their scheduled control period |
url | https://energy.bntu.by/jour/article/view/422 |
work_keys_str_mv | AT yarolik higherreliabilityofelectricpowersupplyunderwindelectricalinstallationoperationingeneralpowersystembyoptimizationoftheirscheduledcontrolperiod AT avgornostay higherreliabilityofelectricpowersupplyunderwindelectricalinstallationoperationingeneralpowersystembyoptimizationoftheirscheduledcontrolperiod |