Graphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion

Abstract This study presents the first application of a graphene/cobalt hexacyanoferrate composite as an ion-to-electron transducer interlayer for the selective electrochemical determination of bupropion. The composite was prepared by homogeneously dispersing graphene with tween 80 and then decorati...

Full description

Saved in:
Bibliographic Details
Main Authors: Eman M. Moaaz, Ahmed S. Fayed, Mamdouh R. Rezk, Ezzat M. Abdel-Moety
Format: Article
Language:English
Published: Nature Portfolio 2025-08-01
Series:Scientific Reports
Subjects:
Online Access:https://doi.org/10.1038/s41598-025-16259-z
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849226379752636416
author Eman M. Moaaz
Ahmed S. Fayed
Mamdouh R. Rezk
Ezzat M. Abdel-Moety
author_facet Eman M. Moaaz
Ahmed S. Fayed
Mamdouh R. Rezk
Ezzat M. Abdel-Moety
author_sort Eman M. Moaaz
collection DOAJ
description Abstract This study presents the first application of a graphene/cobalt hexacyanoferrate composite as an ion-to-electron transducer interlayer for the selective electrochemical determination of bupropion. The composite was prepared by homogeneously dispersing graphene with tween 80 and then decorating it with cobalt-hexacyanoferrate nanoparticles. Modifying glassy carbon electrodes with this interlayer improved and stabilized the measured potential by preventing the formation of an aqueous layer beneath the sensing membrane and enhancing charge transfer. The formation of the aqueous layer is a phenomenon commonly associated with solid-contact ion-selective electrodes. These electrodes encounter challenges regarding selectivity affecting their analytical performance in the presence of ions with similar charges and proper lipophilicity. Molecularly imprinted polymer (MIP) approach was employed to resolve the selectivity problem of analyzing bupropion in presence of naltrexone for obesity management. Scanning electron microscope and Fourier-transform infrared were utilized to characterize the fabricated composite and the MIP. Two cationic exchangers were separately integrated with the precipitated MIP to produce sensors for selective determination of bupropion in the dosage form and in spiked human plasma. The sensors exhibited Nernstian slope of 54.66 mV/decade and 55.89 mV/decade with detection limits as low as 2.51 × 10− 7 M and 2.0 × 10− 7 M. Moreover, three different metric ways verified sufficient sustainability of the proposed potentiometric method.
format Article
id doaj-art-c559f3405cf044818bfc210e2cc07df4
institution Kabale University
issn 2045-2322
language English
publishDate 2025-08-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj-art-c559f3405cf044818bfc210e2cc07df42025-08-24T11:22:40ZengNature PortfolioScientific Reports2045-23222025-08-0115111510.1038/s41598-025-16259-zGraphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropionEman M. Moaaz0Ahmed S. Fayed1Mamdouh R. Rezk2Ezzat M. Abdel-Moety3Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo UniversityPharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo UniversityPharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo UniversityPharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo UniversityAbstract This study presents the first application of a graphene/cobalt hexacyanoferrate composite as an ion-to-electron transducer interlayer for the selective electrochemical determination of bupropion. The composite was prepared by homogeneously dispersing graphene with tween 80 and then decorating it with cobalt-hexacyanoferrate nanoparticles. Modifying glassy carbon electrodes with this interlayer improved and stabilized the measured potential by preventing the formation of an aqueous layer beneath the sensing membrane and enhancing charge transfer. The formation of the aqueous layer is a phenomenon commonly associated with solid-contact ion-selective electrodes. These electrodes encounter challenges regarding selectivity affecting their analytical performance in the presence of ions with similar charges and proper lipophilicity. Molecularly imprinted polymer (MIP) approach was employed to resolve the selectivity problem of analyzing bupropion in presence of naltrexone for obesity management. Scanning electron microscope and Fourier-transform infrared were utilized to characterize the fabricated composite and the MIP. Two cationic exchangers were separately integrated with the precipitated MIP to produce sensors for selective determination of bupropion in the dosage form and in spiked human plasma. The sensors exhibited Nernstian slope of 54.66 mV/decade and 55.89 mV/decade with detection limits as low as 2.51 × 10− 7 M and 2.0 × 10− 7 M. Moreover, three different metric ways verified sufficient sustainability of the proposed potentiometric method.https://doi.org/10.1038/s41598-025-16259-zBupropionCobalt hexacyanoferrateGrapheneMolecularly imprinted polymerSolid-Contact ion selective electrode
spellingShingle Eman M. Moaaz
Ahmed S. Fayed
Mamdouh R. Rezk
Ezzat M. Abdel-Moety
Graphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
Scientific Reports
Bupropion
Cobalt hexacyanoferrate
Graphene
Molecularly imprinted polymer
Solid-Contact ion selective electrode
title Graphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
title_full Graphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
title_fullStr Graphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
title_full_unstemmed Graphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
title_short Graphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
title_sort graphene cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
topic Bupropion
Cobalt hexacyanoferrate
Graphene
Molecularly imprinted polymer
Solid-Contact ion selective electrode
url https://doi.org/10.1038/s41598-025-16259-z
work_keys_str_mv AT emanmmoaaz graphenecobalthexacyanoferratemodifiedsensordopedwithmolecularlyimprintedpolymerforselectivepotentiometricdeterminationofbupropion
AT ahmedsfayed graphenecobalthexacyanoferratemodifiedsensordopedwithmolecularlyimprintedpolymerforselectivepotentiometricdeterminationofbupropion
AT mamdouhrrezk graphenecobalthexacyanoferratemodifiedsensordopedwithmolecularlyimprintedpolymerforselectivepotentiometricdeterminationofbupropion
AT ezzatmabdelmoety graphenecobalthexacyanoferratemodifiedsensordopedwithmolecularlyimprintedpolymerforselectivepotentiometricdeterminationofbupropion