Aplicabilidade de um Protótipo para Determinação da Dose Absorvida Utilizando Equipamentos de Braquiterapia com Fontes de 192Ir

In the intention to have a "body of evidence" that can be used in quality control (QA) of hospitals and clinics that provide services for the treatment of patients with malignancies sources Ir - 192 (brachytherapy with high rates of dose) a system with Fricke dosimetry was developed by res...

Full description

Saved in:
Bibliographic Details
Main Authors: Vivianne L. B. Souza, Rízia K. Nascimento, Cássia K. L. Fonseca, Suzana O. Santos, Waldecy A. Silva
Format: Article
Language:English
Published: Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) 2015-05-01
Series:Brazilian Journal of Radiation Sciences
Subjects:
Online Access:https://bjrs.org.br/revista/index.php/REVISTA/article/view/153
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849317913946750976
author Vivianne L. B. Souza
Rízia K. Nascimento
Cássia K. L. Fonseca
Suzana O. Santos
Waldecy A. Silva
author_facet Vivianne L. B. Souza
Rízia K. Nascimento
Cássia K. L. Fonseca
Suzana O. Santos
Waldecy A. Silva
author_sort Vivianne L. B. Souza
collection DOAJ
description In the intention to have a "body of evidence" that can be used in quality control (QA) of hospitals and clinics that provide services for the treatment of patients with malignancies sources Ir - 192 (brachytherapy with high rates of dose) a system with Fricke dosimetry was developed by researchers at the Centro Regional de Ciências Nucleares (CRCN) and is being used in public and private institutions of laboratories throughout the Northeast and Southeast Brazilian, where they are irradiated samples in triplicate with a dose of 150 or 300 cGy over a distance of 2.5 cm from the source. This work aims at the development and improvement of a device to perform the absolute dosimetry of Ir - 192 sources using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid diluted in distilled water three pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Couter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. Could be seen by the obtained results that the states of Pernambuco, Ceará, Paraíba and Piauí are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose.
format Article
id doaj-art-c52394d084084eb6b9287c833dd0f555
institution Kabale University
issn 2319-0612
language English
publishDate 2015-05-01
publisher Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
record_format Article
series Brazilian Journal of Radiation Sciences
spelling doaj-art-c52394d084084eb6b9287c833dd0f5552025-08-20T03:51:03ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122015-05-0131A (Suppl.)10.15392/bjrs.v3i1A.153120Aplicabilidade de um Protótipo para Determinação da Dose Absorvida Utilizando Equipamentos de Braquiterapia com Fontes de 192IrVivianne L. B. Souza0Rízia K. NascimentoCássia K. L. Fonseca1Suzana O. Santos2Waldecy A. Silva3Centro Regional de Ciências Nucleares/Comissão Nacional de energia NuclearCentro Regional de Ciências Nucleares/Comissão Nacional de Energia NuclearCentro Regional de Ciências Nucleares/Comissão Nacional de Energia NuclearCentro Regional de Ciências Nucleares/Comissão Nacional de Energia NuclearIn the intention to have a "body of evidence" that can be used in quality control (QA) of hospitals and clinics that provide services for the treatment of patients with malignancies sources Ir - 192 (brachytherapy with high rates of dose) a system with Fricke dosimetry was developed by researchers at the Centro Regional de Ciências Nucleares (CRCN) and is being used in public and private institutions of laboratories throughout the Northeast and Southeast Brazilian, where they are irradiated samples in triplicate with a dose of 150 or 300 cGy over a distance of 2.5 cm from the source. This work aims at the development and improvement of a device to perform the absolute dosimetry of Ir - 192 sources using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid diluted in distilled water three pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Couter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. Could be seen by the obtained results that the states of Pernambuco, Ceará, Paraíba and Piauí are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose.https://bjrs.org.br/revista/index.php/REVISTA/article/view/153brachytherapydosimeterquality control
spellingShingle Vivianne L. B. Souza
Rízia K. Nascimento
Cássia K. L. Fonseca
Suzana O. Santos
Waldecy A. Silva
Aplicabilidade de um Protótipo para Determinação da Dose Absorvida Utilizando Equipamentos de Braquiterapia com Fontes de 192Ir
Brazilian Journal of Radiation Sciences
brachytherapy
dosimeter
quality control
title Aplicabilidade de um Protótipo para Determinação da Dose Absorvida Utilizando Equipamentos de Braquiterapia com Fontes de 192Ir
title_full Aplicabilidade de um Protótipo para Determinação da Dose Absorvida Utilizando Equipamentos de Braquiterapia com Fontes de 192Ir
title_fullStr Aplicabilidade de um Protótipo para Determinação da Dose Absorvida Utilizando Equipamentos de Braquiterapia com Fontes de 192Ir
title_full_unstemmed Aplicabilidade de um Protótipo para Determinação da Dose Absorvida Utilizando Equipamentos de Braquiterapia com Fontes de 192Ir
title_short Aplicabilidade de um Protótipo para Determinação da Dose Absorvida Utilizando Equipamentos de Braquiterapia com Fontes de 192Ir
title_sort aplicabilidade de um prototipo para determinacao da dose absorvida utilizando equipamentos de braquiterapia com fontes de 192ir
topic brachytherapy
dosimeter
quality control
url https://bjrs.org.br/revista/index.php/REVISTA/article/view/153
work_keys_str_mv AT viviannelbsouza aplicabilidadedeumprototipoparadeterminacaodadoseabsorvidautilizandoequipamentosdebraquiterapiacomfontesde192ir
AT riziaknascimento aplicabilidadedeumprototipoparadeterminacaodadoseabsorvidautilizandoequipamentosdebraquiterapiacomfontesde192ir
AT cassiaklfonseca aplicabilidadedeumprototipoparadeterminacaodadoseabsorvidautilizandoequipamentosdebraquiterapiacomfontesde192ir
AT suzanaosantos aplicabilidadedeumprototipoparadeterminacaodadoseabsorvidautilizandoequipamentosdebraquiterapiacomfontesde192ir
AT waldecyasilva aplicabilidadedeumprototipoparadeterminacaodadoseabsorvidautilizandoequipamentosdebraquiterapiacomfontesde192ir