Matched all-pass filtering of the received echoes for range improvement in medical ultrasound imaging

The purpose of this work was to investigate a possibility of using chirp waveforms in very high frequency ultrasound medical imaging to increase range resolution and concurrently maximize penetration depth. It is shown that the improvement in range resolution can be achieved by using appropriately d...

Full description

Saved in:
Bibliographic Details
Main Authors: A. NOWICKI, A. KUBERA, K. RENE, A. LEWIN, T. PAŁKO
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2014-01-01
Series:Archives of Acoustics
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/957
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849318647490674688
author A. NOWICKI
A. KUBERA
K. RENE
A. LEWIN
T. PAŁKO
author_facet A. NOWICKI
A. KUBERA
K. RENE
A. LEWIN
T. PAŁKO
author_sort A. NOWICKI
collection DOAJ
description The purpose of this work was to investigate a possibility of using chirp waveforms in very high frequency ultrasound medical imaging to increase range resolution and concurrently maximize penetration depth. It is shown that the improvement in range resolution can be achieved by using appropriately designed all pass matched filter at the receiver input. The paper describes in depth theoretical optimization process and computer simulation of the matched 96-th order all pass filter for chirp waveforms of 1 μs duration in the frequency range 30 MHz-50 MHz. A prototype of 24-th order filter was constructed to verify the results of analytical and numerical methods. Excellent agreement was observed between the theoretical predictions and experimental data. Continuation of this work will include design and optimization of superwide bandwidth transducers.
format Article
id doaj-art-c4cfe8badb8642dabd71d2f6c292e6cb
institution Kabale University
issn 0137-5075
2300-262X
language English
publishDate 2014-01-01
publisher Institute of Fundamental Technological Research Polish Academy of Sciences
record_format Article
series Archives of Acoustics
spelling doaj-art-c4cfe8badb8642dabd71d2f6c292e6cb2025-08-20T03:50:45ZengInstitute of Fundamental Technological Research Polish Academy of SciencesArchives of Acoustics0137-50752300-262X2014-01-01223Matched all-pass filtering of the received echoes for range improvement in medical ultrasound imagingA. NOWICKI0A. KUBERA1K. RENE2A. LEWIN3T. PAŁKO4Department of Ultrasound, Institute of Fundamental Technological Research Polish Academy of SciencesDepartment of Ultrasound, Institute of Fundamental Technological Research Polish Academy of SciencesDepartment of Ultrasound, Institute of Fundamental Technological Research Polish Academy of SciencesDrexel UniversityWarsaw University of TechnologyThe purpose of this work was to investigate a possibility of using chirp waveforms in very high frequency ultrasound medical imaging to increase range resolution and concurrently maximize penetration depth. It is shown that the improvement in range resolution can be achieved by using appropriately designed all pass matched filter at the receiver input. The paper describes in depth theoretical optimization process and computer simulation of the matched 96-th order all pass filter for chirp waveforms of 1 μs duration in the frequency range 30 MHz-50 MHz. A prototype of 24-th order filter was constructed to verify the results of analytical and numerical methods. Excellent agreement was observed between the theoretical predictions and experimental data. Continuation of this work will include design and optimization of superwide bandwidth transducers.https://acoustics.ippt.pan.pl/index.php/aa/article/view/957
spellingShingle A. NOWICKI
A. KUBERA
K. RENE
A. LEWIN
T. PAŁKO
Matched all-pass filtering of the received echoes for range improvement in medical ultrasound imaging
Archives of Acoustics
title Matched all-pass filtering of the received echoes for range improvement in medical ultrasound imaging
title_full Matched all-pass filtering of the received echoes for range improvement in medical ultrasound imaging
title_fullStr Matched all-pass filtering of the received echoes for range improvement in medical ultrasound imaging
title_full_unstemmed Matched all-pass filtering of the received echoes for range improvement in medical ultrasound imaging
title_short Matched all-pass filtering of the received echoes for range improvement in medical ultrasound imaging
title_sort matched all pass filtering of the received echoes for range improvement in medical ultrasound imaging
url https://acoustics.ippt.pan.pl/index.php/aa/article/view/957
work_keys_str_mv AT anowicki matchedallpassfilteringofthereceivedechoesforrangeimprovementinmedicalultrasoundimaging
AT akubera matchedallpassfilteringofthereceivedechoesforrangeimprovementinmedicalultrasoundimaging
AT krene matchedallpassfilteringofthereceivedechoesforrangeimprovementinmedicalultrasoundimaging
AT alewin matchedallpassfilteringofthereceivedechoesforrangeimprovementinmedicalultrasoundimaging
AT tpałko matchedallpassfilteringofthereceivedechoesforrangeimprovementinmedicalultrasoundimaging