Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power System

This paper presents an application of the recently introduced Antlion Optimizer (ALO) to find the parameters of primary governor loop of thermal generators for successful Automatic Generation Control (AGC) of two-area interconnected power system. Two standard objective functions, Integral Square Err...

Full description

Saved in:
Bibliographic Details
Main Authors: Esha Gupta, Akash Saxena
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:Journal of Engineering
Online Access:http://dx.doi.org/10.1155/2016/4570617
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832555809736753152
author Esha Gupta
Akash Saxena
author_facet Esha Gupta
Akash Saxena
author_sort Esha Gupta
collection DOAJ
description This paper presents an application of the recently introduced Antlion Optimizer (ALO) to find the parameters of primary governor loop of thermal generators for successful Automatic Generation Control (AGC) of two-area interconnected power system. Two standard objective functions, Integral Square Error (ISE) and Integral Time Absolute Error (ITAE), have been employed to carry out this parameter estimation process. The problem is transformed in optimization problem to obtain integral gains, speed regulation, and frequency sensitivity coefficient for both areas. The comparison of the regulator performance obtained from ALO is carried out with Genetic Algorithm (GA), Particle Swarm Optimization (PSO), and Gravitational Search Algorithm (GSA) based regulators. Different types of perturbations and load changes are incorporated to establish the efficacy of the obtained design. It is observed that ALO outperforms all three optimization methods for this real problem. The optimization performance of ALO is compared with other algorithms on the basis of standard deviations in the values of parameters and objective functions.
format Article
id doaj-art-c4210bedd05d46ba9b2b2de13d89e8aa
institution Kabale University
issn 2314-4904
2314-4912
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series Journal of Engineering
spelling doaj-art-c4210bedd05d46ba9b2b2de13d89e8aa2025-02-03T05:47:09ZengWileyJournal of Engineering2314-49042314-49122016-01-01201610.1155/2016/45706174570617Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power SystemEsha Gupta0Akash Saxena1Department of Electrical Engineering, Swami Keshvanand Institute of Technology, Management and Gramothan, Office No. AC-201, Ramnagaria, Jagatpura, Jaipur, Rajasthan 302017, IndiaDepartment of Electrical Engineering, Swami Keshvanand Institute of Technology, Management and Gramothan, Office No. AC-201, Ramnagaria, Jagatpura, Jaipur, Rajasthan 302017, IndiaThis paper presents an application of the recently introduced Antlion Optimizer (ALO) to find the parameters of primary governor loop of thermal generators for successful Automatic Generation Control (AGC) of two-area interconnected power system. Two standard objective functions, Integral Square Error (ISE) and Integral Time Absolute Error (ITAE), have been employed to carry out this parameter estimation process. The problem is transformed in optimization problem to obtain integral gains, speed regulation, and frequency sensitivity coefficient for both areas. The comparison of the regulator performance obtained from ALO is carried out with Genetic Algorithm (GA), Particle Swarm Optimization (PSO), and Gravitational Search Algorithm (GSA) based regulators. Different types of perturbations and load changes are incorporated to establish the efficacy of the obtained design. It is observed that ALO outperforms all three optimization methods for this real problem. The optimization performance of ALO is compared with other algorithms on the basis of standard deviations in the values of parameters and objective functions.http://dx.doi.org/10.1155/2016/4570617
spellingShingle Esha Gupta
Akash Saxena
Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power System
Journal of Engineering
title Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power System
title_full Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power System
title_fullStr Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power System
title_full_unstemmed Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power System
title_short Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power System
title_sort performance evaluation of antlion optimizer based regulator in automatic generation control of interconnected power system
url http://dx.doi.org/10.1155/2016/4570617
work_keys_str_mv AT eshagupta performanceevaluationofantlionoptimizerbasedregulatorinautomaticgenerationcontrolofinterconnectedpowersystem
AT akashsaxena performanceevaluationofantlionoptimizerbasedregulatorinautomaticgenerationcontrolofinterconnectedpowersystem