Electrochemical Sensing of Nicotine Using Laser-Induced Graphene Screen-Printed Electrode

Nicotine is one of the major addictive substances in tobacco plants, which caused a global pandemic. Rapid detection of nicotine is crucial to allow quick identification of harmful substances that will cause significant health risks, especially with the recent rise in electronic cigarettes. Since s...

Full description

Saved in:
Bibliographic Details
Main Authors: Balqis Nurnadia Badrol Hisham, Rosminazuin Ab. Rahim, Anis Nurashikin Nordin, Aliza Aini Md Ralib, Nor Farahidah Za'bah, Lun Hao Tung, Zainiharyati Mohd Zain
Format: Article
Language:English
Published: IIUM Press, International Islamic University Malaysia 2025-01-01
Series:International Islamic University Malaysia Engineering Journal
Subjects:
Online Access:https://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/3392
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850113433320554496
author Balqis Nurnadia Badrol Hisham
Rosminazuin Ab. Rahim
Anis Nurashikin Nordin
Aliza Aini Md Ralib
Nor Farahidah Za'bah
Lun Hao Tung
Zainiharyati Mohd Zain
author_facet Balqis Nurnadia Badrol Hisham
Rosminazuin Ab. Rahim
Anis Nurashikin Nordin
Aliza Aini Md Ralib
Nor Farahidah Za'bah
Lun Hao Tung
Zainiharyati Mohd Zain
author_sort Balqis Nurnadia Badrol Hisham
collection DOAJ
description Nicotine is one of the major addictive substances in tobacco plants, which caused a global pandemic. Rapid detection of nicotine is crucial to allow quick identification of harmful substances that will cause significant health risks, especially with the recent rise in electronic cigarettes. Since smoking cessation programs are typically limited to screening, awareness, consultation, medication, and follow-up activities, there is a need for a device to check the nicotine level in former smokers at the end of the programs. However, most of the current nicotine detection is based on chromatography technology, which involves complicated sample pre-treatment and bulky and expensive instruments. Thus, screen-printing technology employing electrochemical detection is a promising solution as it offers a simple and portable setup for nicotine detection. Yet, conventional screen-printed electrodes (SPE) have relatively low sensitivity and need modification to improve the electrode material. Therefore, this work aims to investigate the performance of laser-induced graphene (LIG) as SPE-modified electrodes to detect the presence of nicotine through electrochemical measurements. A finite element simulation was conducted to investigate laser power's effect on the induced graphene's quality. The CO2 laser with 3W laser power, Dots per inch (DPI) of 1200, and a laser speed of 13% was used to fabricate the LIG sensor on a Kapton substrate. Material characterizations such as SEM, EDX, and Raman spectra were performed on the fabricated LIG-SPE to confirm the presence of LIG. Cyclic voltammetry (CV) measurement was done using 0.1M [Fe (CN)6]3-/4- and 0.1M KCL to find the suitable scan rates. At a fixed scan rate of 50 mV/s, the sensor's performance was analyzed using 0.1M of nicotine with 3 different phosphate buffer solutions (PBS) of pH 5, pH 7, and pH 9 at different nicotine concentrations. Nicotine with PBS pH 5 solution was found to be the optimum measured solution, with the value obtained for R² having the highest value of 0.9988 and the lowest LOD of 4.2183 ?M. The proposed electrochemical sensing of nicotine using a laser-induced graphene screen printed electrode can detect nicotine with high linearity at different pH levels of PBS buffer solution. ABSTRAK: Nikotin adalah salah satu bahan ketagihan utama dalam tumbuhan tembakau yang menyebabkan pandemik global. Pengesanan cepat nikotin adalah penting bagi membolehkan pengecaman cepat bahan merbahaya yang menyebabkan risiko kesihatan ketara terutamanya dengan peningkatan rokok elektronik pada masa sekarang. Memandangkan program berhenti merokok biasanya terhad kepada pemeriksaan, kesedaran, perundingan, ubat-ubatan dan aktiviti susulan, terdapat keperluan bagi peranti memeriksa tahap nikotin dalam bekas perokok pada akhir program. Walau bagaimanapun, kebanyakan pengesanan nikotin semasa adalah berdasarkan teknologi kromatografi, di mana melibatkan sampel pra-rawatan rumit, instrumen besar dan mahal. Oleh itu, teknologi percetakan skrin yang menggunakan pengesanan eletrokimia adalah penyelesaian bermakna kerana ia menawarkan persediaan mudah dan mudah alih bagi mengesan nikotin. Namun, skrin-cetakan elektrod konvensional (SPE) mempunyai sensitiviti rendah dan memerlukan pengubahsuaian bagi menambah baik bahan elektrod. Oleh itu, kajian ini adalah untuk menyiasat prestasi laser graphen teraruh (LIG) sebagai elektrod SPE yang diubah suai bagi mengesan kehadiran nikotin melalui pengukuran elektrokimia. Simulasi unsur terhingga telah dijalankan bagi melihat kesan kuasa laser ke atas kualiti graphen teraruh. Laser CO? dengan kuasa laser 3W, dot per inci (DPI) sebanyak 1200, dan kelajuan laser sehingga 13% telah digunakan bagi mengfabrikasi pengimbas LIG pada substrat Kapton. Pencirian bahan sperti SEM, EDX, dan spektrum Raman dilakukan pada LIG-SPE yang direka bagi mengesahkan kehadiran LIG. Pengukuran voltametri kitaran (CV) dilakukan menggunakan 0.1M [Fe (CN)6]3-/4- dan 0.1M KCL bagi mencari kadar imbasan yang sesuai. Pada kadar imbasan tetap 50 mV/s, prestasi pengimbas dianalisa menggunakan 0.1M nikotin dengan 3 larutan penimbal fosfat (PBS) berbeza pH 5, pH 7, dan pH 9 pada kepekatan nikotin berbeza. Nikotin dengan larutan PBS pH 5 didapati sebagai larutan optimum, dengan nilai R² tertinggi 0.9988 dan LOD terendah 4.2183 ?M. Kesimpulannya, pengimbas elektrokimia nikotin menggunakan laser elektrod skrin bercetak graphen teraruh dapat mengesan nikotin dengan pemalaran tinggi pada pH larutan penimbal PBS yang berbeza.
format Article
id doaj-art-c3d4bce199b54017b3bdf4859570f4f5
institution OA Journals
issn 1511-788X
2289-7860
language English
publishDate 2025-01-01
publisher IIUM Press, International Islamic University Malaysia
record_format Article
series International Islamic University Malaysia Engineering Journal
spelling doaj-art-c3d4bce199b54017b3bdf4859570f4f52025-08-20T02:37:09ZengIIUM Press, International Islamic University MalaysiaInternational Islamic University Malaysia Engineering Journal1511-788X2289-78602025-01-0126110.31436/iiumej.v26i1.3392Electrochemical Sensing of Nicotine Using Laser-Induced Graphene Screen-Printed ElectrodeBalqis Nurnadia Badrol Hisham0https://orcid.org/0009-0000-0381-2328Rosminazuin Ab. Rahim1https://orcid.org/0000-0002-7220-9183Anis Nurashikin Nordin2https://orcid.org/0000-0002-8301-4365Aliza Aini Md Ralib3https://orcid.org/0000-0001-6786-1735Nor Farahidah Za'bah4https://orcid.org/0000-0002-8226-3247Lun Hao Tung5https://orcid.org/0000-0002-9335-614XZainiharyati Mohd Zain6https://orcid.org/0000-0002-0247-2031International Islamic University Malaysia International Islamic University Malaysia International Islamic University Malaysia International Islamic University Malaysia International Islamic University Malaysia Jabil Circuit Sdn BhdUniversiti Teknologi MARA Nicotine is one of the major addictive substances in tobacco plants, which caused a global pandemic. Rapid detection of nicotine is crucial to allow quick identification of harmful substances that will cause significant health risks, especially with the recent rise in electronic cigarettes. Since smoking cessation programs are typically limited to screening, awareness, consultation, medication, and follow-up activities, there is a need for a device to check the nicotine level in former smokers at the end of the programs. However, most of the current nicotine detection is based on chromatography technology, which involves complicated sample pre-treatment and bulky and expensive instruments. Thus, screen-printing technology employing electrochemical detection is a promising solution as it offers a simple and portable setup for nicotine detection. Yet, conventional screen-printed electrodes (SPE) have relatively low sensitivity and need modification to improve the electrode material. Therefore, this work aims to investigate the performance of laser-induced graphene (LIG) as SPE-modified electrodes to detect the presence of nicotine through electrochemical measurements. A finite element simulation was conducted to investigate laser power's effect on the induced graphene's quality. The CO2 laser with 3W laser power, Dots per inch (DPI) of 1200, and a laser speed of 13% was used to fabricate the LIG sensor on a Kapton substrate. Material characterizations such as SEM, EDX, and Raman spectra were performed on the fabricated LIG-SPE to confirm the presence of LIG. Cyclic voltammetry (CV) measurement was done using 0.1M [Fe (CN)6]3-/4- and 0.1M KCL to find the suitable scan rates. At a fixed scan rate of 50 mV/s, the sensor's performance was analyzed using 0.1M of nicotine with 3 different phosphate buffer solutions (PBS) of pH 5, pH 7, and pH 9 at different nicotine concentrations. Nicotine with PBS pH 5 solution was found to be the optimum measured solution, with the value obtained for R² having the highest value of 0.9988 and the lowest LOD of 4.2183 ?M. The proposed electrochemical sensing of nicotine using a laser-induced graphene screen printed electrode can detect nicotine with high linearity at different pH levels of PBS buffer solution. ABSTRAK: Nikotin adalah salah satu bahan ketagihan utama dalam tumbuhan tembakau yang menyebabkan pandemik global. Pengesanan cepat nikotin adalah penting bagi membolehkan pengecaman cepat bahan merbahaya yang menyebabkan risiko kesihatan ketara terutamanya dengan peningkatan rokok elektronik pada masa sekarang. Memandangkan program berhenti merokok biasanya terhad kepada pemeriksaan, kesedaran, perundingan, ubat-ubatan dan aktiviti susulan, terdapat keperluan bagi peranti memeriksa tahap nikotin dalam bekas perokok pada akhir program. Walau bagaimanapun, kebanyakan pengesanan nikotin semasa adalah berdasarkan teknologi kromatografi, di mana melibatkan sampel pra-rawatan rumit, instrumen besar dan mahal. Oleh itu, teknologi percetakan skrin yang menggunakan pengesanan eletrokimia adalah penyelesaian bermakna kerana ia menawarkan persediaan mudah dan mudah alih bagi mengesan nikotin. Namun, skrin-cetakan elektrod konvensional (SPE) mempunyai sensitiviti rendah dan memerlukan pengubahsuaian bagi menambah baik bahan elektrod. Oleh itu, kajian ini adalah untuk menyiasat prestasi laser graphen teraruh (LIG) sebagai elektrod SPE yang diubah suai bagi mengesan kehadiran nikotin melalui pengukuran elektrokimia. Simulasi unsur terhingga telah dijalankan bagi melihat kesan kuasa laser ke atas kualiti graphen teraruh. Laser CO? dengan kuasa laser 3W, dot per inci (DPI) sebanyak 1200, dan kelajuan laser sehingga 13% telah digunakan bagi mengfabrikasi pengimbas LIG pada substrat Kapton. Pencirian bahan sperti SEM, EDX, dan spektrum Raman dilakukan pada LIG-SPE yang direka bagi mengesahkan kehadiran LIG. Pengukuran voltametri kitaran (CV) dilakukan menggunakan 0.1M [Fe (CN)6]3-/4- dan 0.1M KCL bagi mencari kadar imbasan yang sesuai. Pada kadar imbasan tetap 50 mV/s, prestasi pengimbas dianalisa menggunakan 0.1M nikotin dengan 3 larutan penimbal fosfat (PBS) berbeza pH 5, pH 7, dan pH 9 pada kepekatan nikotin berbeza. Nikotin dengan larutan PBS pH 5 didapati sebagai larutan optimum, dengan nilai R² tertinggi 0.9988 dan LOD terendah 4.2183 ?M. Kesimpulannya, pengimbas elektrokimia nikotin menggunakan laser elektrod skrin bercetak graphen teraruh dapat mengesan nikotin dengan pemalaran tinggi pada pH larutan penimbal PBS yang berbeza. https://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/3392laser-induced graphenescreen-printed electrodenicotineelectrochemical
spellingShingle Balqis Nurnadia Badrol Hisham
Rosminazuin Ab. Rahim
Anis Nurashikin Nordin
Aliza Aini Md Ralib
Nor Farahidah Za'bah
Lun Hao Tung
Zainiharyati Mohd Zain
Electrochemical Sensing of Nicotine Using Laser-Induced Graphene Screen-Printed Electrode
International Islamic University Malaysia Engineering Journal
laser-induced graphene
screen-printed electrode
nicotine
electrochemical
title Electrochemical Sensing of Nicotine Using Laser-Induced Graphene Screen-Printed Electrode
title_full Electrochemical Sensing of Nicotine Using Laser-Induced Graphene Screen-Printed Electrode
title_fullStr Electrochemical Sensing of Nicotine Using Laser-Induced Graphene Screen-Printed Electrode
title_full_unstemmed Electrochemical Sensing of Nicotine Using Laser-Induced Graphene Screen-Printed Electrode
title_short Electrochemical Sensing of Nicotine Using Laser-Induced Graphene Screen-Printed Electrode
title_sort electrochemical sensing of nicotine using laser induced graphene screen printed electrode
topic laser-induced graphene
screen-printed electrode
nicotine
electrochemical
url https://journals.iium.edu.my/ejournal/index.php/iiumej/article/view/3392
work_keys_str_mv AT balqisnurnadiabadrolhisham electrochemicalsensingofnicotineusinglaserinducedgraphenescreenprintedelectrode
AT rosminazuinabrahim electrochemicalsensingofnicotineusinglaserinducedgraphenescreenprintedelectrode
AT anisnurashikinnordin electrochemicalsensingofnicotineusinglaserinducedgraphenescreenprintedelectrode
AT alizaainimdralib electrochemicalsensingofnicotineusinglaserinducedgraphenescreenprintedelectrode
AT norfarahidahzabah electrochemicalsensingofnicotineusinglaserinducedgraphenescreenprintedelectrode
AT lunhaotung electrochemicalsensingofnicotineusinglaserinducedgraphenescreenprintedelectrode
AT zainiharyatimohdzain electrochemicalsensingofnicotineusinglaserinducedgraphenescreenprintedelectrode