Occurrence and Mitigation of PM<sub>2.5</sub>, NO<sub>2</sub>, CO and CO<sub>2</sub> in Homes Due to Cooking and Gas Stoves

We surveyed the air quality conditions in 18 homes with gas stoves for PM<sub>2.5</sub>, CO<sub>2</sub>, NO<sub>2</sub> and CO using calibrated low-cost sensors. In each home, participants were asked to cook as usual, but to record their cooking activities and mit...

Full description

Saved in:
Bibliographic Details
Main Authors: Daniel Jaffe, Devon Nirschl, Stephanie Birman
Format: Article
Language:English
Published: MDPI AG 2025-07-01
Series:Atmosphere
Subjects:
Online Access:https://www.mdpi.com/2073-4433/16/7/882
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849409576318795776
author Daniel Jaffe
Devon Nirschl
Stephanie Birman
author_facet Daniel Jaffe
Devon Nirschl
Stephanie Birman
author_sort Daniel Jaffe
collection DOAJ
description We surveyed the air quality conditions in 18 homes with gas stoves for PM<sub>2.5</sub>, CO<sub>2</sub>, NO<sub>2</sub> and CO using calibrated low-cost sensors. In each home, participants were asked to cook as usual, but to record their cooking activities and mitigation efforts (windows, ventilation fans, etc.). All homes showed enhanced pollutants during, and immediately after, times of cooking or stove use. For each home, we quantified the minutes per day and minutes per minute of cooking over known health thresholds for each pollutant. On average, homes exhibited 38 min per day over one or more of these thresholds, with PM<sub>2.5</sub> and NO<sub>2</sub> being the pollutants of greatest concern. Six homes had much higher occurrences over the health thresholds, averaging 73 min per day. We found an average of 1.0 min over one or more of the health thresholds per minute of cooking when no mitigation was used, whereas when mitigation was used (filtration or vent fan), this value was reduced by 34%. We further investigated several mitigation methods including natural diffusion, a commercial HEPA filter unit, a commercial O<sub>3</sub> scrubber and a ventilation fan. We found that the HEPA unit was highly effective for PM<sub>2.5</sub> but had no impact on any of the gaseous pollutants. The O<sub>3</sub> scrubber was moderately effective for NO<sub>2</sub> but had little impact on the other pollutants. The ventilation fan was highly effective for all pollutants and reduced the average pollutant lifetime significantly. Under controlled test conditions, the pollutant lifetime (or time to reach 37% of the original concentration), was reduced from an average of 45 min (with no ventilation) to 7 min. While no commercial filter showed efficacy for both PM<sub>2.5</sub> and NO<sub>2</sub>, the fact that each could be removed individually suggests that a combined filter for both pollutants could be developed, which would significantly reduce health impacts in homes with gas stoves.
format Article
id doaj-art-c3ce2a33060b420ebd17ade517b2b7d5
institution Kabale University
issn 2073-4433
language English
publishDate 2025-07-01
publisher MDPI AG
record_format Article
series Atmosphere
spelling doaj-art-c3ce2a33060b420ebd17ade517b2b7d52025-08-20T03:35:27ZengMDPI AGAtmosphere2073-44332025-07-0116788210.3390/atmos16070882Occurrence and Mitigation of PM<sub>2.5</sub>, NO<sub>2</sub>, CO and CO<sub>2</sub> in Homes Due to Cooking and Gas StovesDaniel Jaffe0Devon Nirschl1Stephanie Birman2School of Science, Technology, Engineering, and Mathematics, University of Washington, Bothell, WA 98011, USASchool of Science, Technology, Engineering, and Mathematics, University of Washington, Bothell, WA 98011, USASchool of Science, Technology, Engineering, and Mathematics, University of Washington, Bothell, WA 98011, USAWe surveyed the air quality conditions in 18 homes with gas stoves for PM<sub>2.5</sub>, CO<sub>2</sub>, NO<sub>2</sub> and CO using calibrated low-cost sensors. In each home, participants were asked to cook as usual, but to record their cooking activities and mitigation efforts (windows, ventilation fans, etc.). All homes showed enhanced pollutants during, and immediately after, times of cooking or stove use. For each home, we quantified the minutes per day and minutes per minute of cooking over known health thresholds for each pollutant. On average, homes exhibited 38 min per day over one or more of these thresholds, with PM<sub>2.5</sub> and NO<sub>2</sub> being the pollutants of greatest concern. Six homes had much higher occurrences over the health thresholds, averaging 73 min per day. We found an average of 1.0 min over one or more of the health thresholds per minute of cooking when no mitigation was used, whereas when mitigation was used (filtration or vent fan), this value was reduced by 34%. We further investigated several mitigation methods including natural diffusion, a commercial HEPA filter unit, a commercial O<sub>3</sub> scrubber and a ventilation fan. We found that the HEPA unit was highly effective for PM<sub>2.5</sub> but had no impact on any of the gaseous pollutants. The O<sub>3</sub> scrubber was moderately effective for NO<sub>2</sub> but had little impact on the other pollutants. The ventilation fan was highly effective for all pollutants and reduced the average pollutant lifetime significantly. Under controlled test conditions, the pollutant lifetime (or time to reach 37% of the original concentration), was reduced from an average of 45 min (with no ventilation) to 7 min. While no commercial filter showed efficacy for both PM<sub>2.5</sub> and NO<sub>2</sub>, the fact that each could be removed individually suggests that a combined filter for both pollutants could be developed, which would significantly reduce health impacts in homes with gas stoves.https://www.mdpi.com/2073-4433/16/7/882indoor airgas stovesparticulate matternitrogen dioxidemitigation
spellingShingle Daniel Jaffe
Devon Nirschl
Stephanie Birman
Occurrence and Mitigation of PM<sub>2.5</sub>, NO<sub>2</sub>, CO and CO<sub>2</sub> in Homes Due to Cooking and Gas Stoves
Atmosphere
indoor air
gas stoves
particulate matter
nitrogen dioxide
mitigation
title Occurrence and Mitigation of PM<sub>2.5</sub>, NO<sub>2</sub>, CO and CO<sub>2</sub> in Homes Due to Cooking and Gas Stoves
title_full Occurrence and Mitigation of PM<sub>2.5</sub>, NO<sub>2</sub>, CO and CO<sub>2</sub> in Homes Due to Cooking and Gas Stoves
title_fullStr Occurrence and Mitigation of PM<sub>2.5</sub>, NO<sub>2</sub>, CO and CO<sub>2</sub> in Homes Due to Cooking and Gas Stoves
title_full_unstemmed Occurrence and Mitigation of PM<sub>2.5</sub>, NO<sub>2</sub>, CO and CO<sub>2</sub> in Homes Due to Cooking and Gas Stoves
title_short Occurrence and Mitigation of PM<sub>2.5</sub>, NO<sub>2</sub>, CO and CO<sub>2</sub> in Homes Due to Cooking and Gas Stoves
title_sort occurrence and mitigation of pm sub 2 5 sub no sub 2 sub co and co sub 2 sub in homes due to cooking and gas stoves
topic indoor air
gas stoves
particulate matter
nitrogen dioxide
mitigation
url https://www.mdpi.com/2073-4433/16/7/882
work_keys_str_mv AT danieljaffe occurrenceandmitigationofpmsub25subnosub2subcoandcosub2subinhomesduetocookingandgasstoves
AT devonnirschl occurrenceandmitigationofpmsub25subnosub2subcoandcosub2subinhomesduetocookingandgasstoves
AT stephaniebirman occurrenceandmitigationofpmsub25subnosub2subcoandcosub2subinhomesduetocookingandgasstoves