Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline

Magnetic flux leakage internal detection is an efficient method for detecting defects in long-distance pipelines.However,some corrosion points (such as stray current corrosion) contain a large amount of ferromagnetic corrosion products, which can affect the overflow of the leakage magnetic field at...

Full description

Saved in:
Bibliographic Details
Main Author: ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin
Format: Article
Language:zho
Published: Editorial Department of Materials Protection 2024-10-01
Series:Cailiao Baohu
Subjects:
Online Access:http://www.mat-pro.com/fileup/1001-1560/PDF/20241025.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850121435338506240
author ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin
author_facet ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin
author_sort ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin
collection DOAJ
description Magnetic flux leakage internal detection is an efficient method for detecting defects in long-distance pipelines.However,some corrosion points (such as stray current corrosion) contain a large amount of ferromagnetic corrosion products, which can affect the overflow of the leakage magnetic field at the defect site, resulting in a smaller evaluation of the detected data and even missed detections.Based on the fundamental principles of magnetic flux leakage internal detection, the reasons for the generation of leakage magnetic fields at defect sites were elucidated.Combined with pull-out tests and practical engineering cases, it was demonstrated that ferromagnetic corrosion products hinder the leakage of magnetic fields at corrosion defects.This provided technical support for enhancing the identification of such defects in the future and improving the effectiveness of pipeline magnetic flux leakage internal detection.
format Article
id doaj-art-c333d7f8a51549f69fcc3db0d968cec3
institution OA Journals
issn 1001-1560
language zho
publishDate 2024-10-01
publisher Editorial Department of Materials Protection
record_format Article
series Cailiao Baohu
spelling doaj-art-c333d7f8a51549f69fcc3db0d968cec32025-08-20T02:35:05ZzhoEditorial Department of Materials ProtectionCailiao Baohu1001-15602024-10-01571020821210.16577/j.issn.1001-1560.2024.0242Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of PipelineZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin0(China Special Equipment Inspection & Research Institute, Technology Innovation Center of Oil And Gas Pipeline and Storage Equipment Safety for State Market Regulation, Beijing 100029, China)Magnetic flux leakage internal detection is an efficient method for detecting defects in long-distance pipelines.However,some corrosion points (such as stray current corrosion) contain a large amount of ferromagnetic corrosion products, which can affect the overflow of the leakage magnetic field at the defect site, resulting in a smaller evaluation of the detected data and even missed detections.Based on the fundamental principles of magnetic flux leakage internal detection, the reasons for the generation of leakage magnetic fields at defect sites were elucidated.Combined with pull-out tests and practical engineering cases, it was demonstrated that ferromagnetic corrosion products hinder the leakage of magnetic fields at corrosion defects.This provided technical support for enhancing the identification of such defects in the future and improving the effectiveness of pipeline magnetic flux leakage internal detection.http://www.mat-pro.com/fileup/1001-1560/PDF/20241025.pdfmagnetic flux leakage internal detection; ferromagnetic corrosion products; leakage magnetic field; data evaluation
spellingShingle ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin
Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline
Cailiao Baohu
magnetic flux leakage internal detection; ferromagnetic corrosion products; leakage magnetic field; data evaluation
title Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline
title_full Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline
title_fullStr Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline
title_full_unstemmed Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline
title_short Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline
title_sort analysis of the influence of ferromagnetic corrosion products on magnetic flux leakage detection of pipeline
topic magnetic flux leakage internal detection; ferromagnetic corrosion products; leakage magnetic field; data evaluation
url http://www.mat-pro.com/fileup/1001-1560/PDF/20241025.pdf
work_keys_str_mv AT zhuxinghuihupengmengxiangjilyutanguobinchenjinzhongzhoudemin analysisoftheinfluenceofferromagneticcorrosionproductsonmagneticfluxleakagedetectionofpipeline