Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline
Magnetic flux leakage internal detection is an efficient method for detecting defects in long-distance pipelines.However,some corrosion points (such as stray current corrosion) contain a large amount of ferromagnetic corrosion products, which can affect the overflow of the leakage magnetic field at...
Saved in:
| Main Author: | |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Department of Materials Protection
2024-10-01
|
| Series: | Cailiao Baohu |
| Subjects: | |
| Online Access: | http://www.mat-pro.com/fileup/1001-1560/PDF/20241025.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850121435338506240 |
|---|---|
| author | ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin |
| author_facet | ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin |
| author_sort | ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin |
| collection | DOAJ |
| description | Magnetic flux leakage internal detection is an efficient method for detecting defects in long-distance pipelines.However,some corrosion points (such as stray current corrosion) contain a large amount of ferromagnetic corrosion products, which can affect the overflow of the leakage magnetic field at the defect site, resulting in a smaller evaluation of the detected data and even missed detections.Based on the fundamental principles of magnetic flux leakage internal detection, the reasons for the generation of leakage magnetic fields at defect sites were elucidated.Combined with pull-out tests and practical engineering cases, it was demonstrated that ferromagnetic corrosion products hinder the leakage of magnetic fields at corrosion defects.This provided technical support for enhancing the identification of such defects in the future and improving the effectiveness of pipeline magnetic flux leakage internal detection. |
| format | Article |
| id | doaj-art-c333d7f8a51549f69fcc3db0d968cec3 |
| institution | OA Journals |
| issn | 1001-1560 |
| language | zho |
| publishDate | 2024-10-01 |
| publisher | Editorial Department of Materials Protection |
| record_format | Article |
| series | Cailiao Baohu |
| spelling | doaj-art-c333d7f8a51549f69fcc3db0d968cec32025-08-20T02:35:05ZzhoEditorial Department of Materials ProtectionCailiao Baohu1001-15602024-10-01571020821210.16577/j.issn.1001-1560.2024.0242Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of PipelineZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin0(China Special Equipment Inspection & Research Institute, Technology Innovation Center of Oil And Gas Pipeline and Storage Equipment Safety for State Market Regulation, Beijing 100029, China)Magnetic flux leakage internal detection is an efficient method for detecting defects in long-distance pipelines.However,some corrosion points (such as stray current corrosion) contain a large amount of ferromagnetic corrosion products, which can affect the overflow of the leakage magnetic field at the defect site, resulting in a smaller evaluation of the detected data and even missed detections.Based on the fundamental principles of magnetic flux leakage internal detection, the reasons for the generation of leakage magnetic fields at defect sites were elucidated.Combined with pull-out tests and practical engineering cases, it was demonstrated that ferromagnetic corrosion products hinder the leakage of magnetic fields at corrosion defects.This provided technical support for enhancing the identification of such defects in the future and improving the effectiveness of pipeline magnetic flux leakage internal detection.http://www.mat-pro.com/fileup/1001-1560/PDF/20241025.pdfmagnetic flux leakage internal detection; ferromagnetic corrosion products; leakage magnetic field; data evaluation |
| spellingShingle | ZHU Xinghui, HU Peng, MENG Xiangji, LYU Tan, GUO Bin, CHEN Jinzhong, ZHOU Demin Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline Cailiao Baohu magnetic flux leakage internal detection; ferromagnetic corrosion products; leakage magnetic field; data evaluation |
| title | Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline |
| title_full | Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline |
| title_fullStr | Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline |
| title_full_unstemmed | Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline |
| title_short | Analysis of the Influence of Ferromagnetic Corrosion Products on Magnetic Flux Leakage Detection of Pipeline |
| title_sort | analysis of the influence of ferromagnetic corrosion products on magnetic flux leakage detection of pipeline |
| topic | magnetic flux leakage internal detection; ferromagnetic corrosion products; leakage magnetic field; data evaluation |
| url | http://www.mat-pro.com/fileup/1001-1560/PDF/20241025.pdf |
| work_keys_str_mv | AT zhuxinghuihupengmengxiangjilyutanguobinchenjinzhongzhoudemin analysisoftheinfluenceofferromagneticcorrosionproductsonmagneticfluxleakagedetectionofpipeline |