PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS

This study was conducted to evaluate the stability and performance of a building using a shear wall system with a building that applies FVD as a seismic damper system. The stability parameters analyzed include displacement, drift ratio, and storey drift. Meanwhile, the structural performance is ana...

Full description

Saved in:
Bibliographic Details
Main Authors: Erwin Rommel, Alfin Bena Tedha, Aulia Indira Kumalasari
Format: Article
Language:English
Published: Universitas Negeri Jakarta 2025-05-01
Series:Jurnal Pensil
Subjects:
Online Access:https://journal.unj.ac.id/unj/index.php/jpensil/article/view/53909
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850111190755180544
author Erwin Rommel
Alfin Bena Tedha
Aulia Indira Kumalasari
author_facet Erwin Rommel
Alfin Bena Tedha
Aulia Indira Kumalasari
author_sort Erwin Rommel
collection DOAJ
description This study was conducted to evaluate the stability and performance of a building using a shear wall system with a building that applies FVD as a seismic damper system. The stability parameters analyzed include displacement, drift ratio, and storey drift. Meanwhile, the structural performance is analyzed based on the number of phases, hysteresis energy generated, and structural performance level. Numerical modeling of the building structure was conducted, and then earthquake loading simulations were carried out using ChiChi, Kobe, and Yushu earthquakes that had been scaled according to the dynamic response analysis procedure. The results show that the use of FVD as an energy dissipation system has significant potential in improving the performance and stability of structures. The performance of this system is shown to match, and in some aspects even compete, the effectiveness of shear walls in reducing the seismic response of building structures. Therefore, FVDs can be considered an efficient alternative in earthquake-resistant building design, especially in structures that require higher flexibility without sacrificing energy dissipation capacity.
format Article
id doaj-art-c29d5f12af7149f498c0ba0ddba13f33
institution OA Journals
issn 2301-8437
2623-1085
language English
publishDate 2025-05-01
publisher Universitas Negeri Jakarta
record_format Article
series Jurnal Pensil
spelling doaj-art-c29d5f12af7149f498c0ba0ddba13f332025-08-20T02:37:39ZengUniversitas Negeri JakartaJurnal Pensil2301-84372623-10852025-05-0114210.21009/jpensil.v14i2.53909PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERSErwin Rommel0Alfin Bena Tedha1Aulia Indira Kumalasari2University of Muhammadiyah MalangUniversity of Muhammadiyah MalangUniversitas Muhammadiyah Malang This study was conducted to evaluate the stability and performance of a building using a shear wall system with a building that applies FVD as a seismic damper system. The stability parameters analyzed include displacement, drift ratio, and storey drift. Meanwhile, the structural performance is analyzed based on the number of phases, hysteresis energy generated, and structural performance level. Numerical modeling of the building structure was conducted, and then earthquake loading simulations were carried out using ChiChi, Kobe, and Yushu earthquakes that had been scaled according to the dynamic response analysis procedure. The results show that the use of FVD as an energy dissipation system has significant potential in improving the performance and stability of structures. The performance of this system is shown to match, and in some aspects even compete, the effectiveness of shear walls in reducing the seismic response of building structures. Therefore, FVDs can be considered an efficient alternative in earthquake-resistant building design, especially in structures that require higher flexibility without sacrificing energy dissipation capacity. https://journal.unj.ac.id/unj/index.php/jpensil/article/view/53909ChiChiKobeYushuFVDShearwall
spellingShingle Erwin Rommel
Alfin Bena Tedha
Aulia Indira Kumalasari
PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS
Jurnal Pensil
ChiChi
Kobe
Yushu
FVD
Shearwall
title PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS
title_full PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS
title_fullStr PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS
title_full_unstemmed PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS
title_short PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS
title_sort performance comparison of buildings with shear wall system and viscous dampers
topic ChiChi
Kobe
Yushu
FVD
Shearwall
url https://journal.unj.ac.id/unj/index.php/jpensil/article/view/53909
work_keys_str_mv AT erwinrommel performancecomparisonofbuildingswithshearwallsystemandviscousdampers
AT alfinbenatedha performancecomparisonofbuildingswithshearwallsystemandviscousdampers
AT auliaindirakumalasari performancecomparisonofbuildingswithshearwallsystemandviscousdampers