THE EFFECTIVENESS OF VALIDATION MEASUREMENTS IN AUTOMATED SYSTEMS OF THE POWER SUPPLY SYSTEMS CONTROL IN ACCORDANCE WITH LIMIT VALUES

A high level of operational reliability of power supply systems is virtually impossible to provide without operational control of the reliability of the measurement variables (currents, voltages, powers, energies, temperatures, pressures) that characterize the condition of power equipment and techno...

Full description

Saved in:
Bibliographic Details
Main Authors: V. A. Anishchenko, T. V. Pisaruk
Format: Article
Language:Russian
Published: Belarusian National Technical University 2017-09-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/1084
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849241654922313728
author V. A. Anishchenko
T. V. Pisaruk
author_facet V. A. Anishchenko
T. V. Pisaruk
author_sort V. A. Anishchenko
collection DOAJ
description A high level of operational reliability of power supply systems is virtually impossible to provide without operational control of the reliability of the measurement variables (currents, voltages, powers, energies, temperatures, pressures) that characterize the condition of power equipment and technological processes. Reforming the power engineering and its transition to market relations necessitate one to toughen the requirements for the reliability of the measuring information. Inaccurate measurements are a potential source of misdiagnosis of malfunctions of equipment and they cause incorrect operation of emergency control equipment and erroneous actions of operating personnel in the control of technological processes. Operational methods of reliability control that enhance the operational reliability of the measuring information are based on the usage of the semantic value of the measured data, their consistency, process consistency, and consistency of balance. These methods use technological sense of the measured variables and they complement the methods of hardware status monitoring of automated control systems based on digital codes. That improves the overall operational reliability of the transmission, collection and processing of information. The most common semantic method of control is the method of limits (“fork”) that compares the numeric value of the measured variable with the upper and lower boundaries of valid values. The disadvantage of limit values in many cases is its poor resolution, due to the wide range of appearance of results of measurements. This reduces the probability of detection of gross and systematic errors of measurements more than it may be accepted. With this regard, the objective of a reasonable narrowing of the range of valid values of the variables, that uses the theory of statistical decisions, acquires high relevance.
format Article
id doaj-art-c26231bc3a9d448b8bbc162b1567b414
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2017-09-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-c26231bc3a9d448b8bbc162b1567b4142025-08-20T04:00:04ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412017-09-0160540741610.21122/1029-7448-2017-60-5-407-4161047THE EFFECTIVENESS OF VALIDATION MEASUREMENTS IN AUTOMATED SYSTEMS OF THE POWER SUPPLY SYSTEMS CONTROL IN ACCORDANCE WITH LIMIT VALUESV. A. Anishchenko0T. V. Pisaruk1Belarusian National Technical UniversityBelarusian National Technical UniversityA high level of operational reliability of power supply systems is virtually impossible to provide without operational control of the reliability of the measurement variables (currents, voltages, powers, energies, temperatures, pressures) that characterize the condition of power equipment and technological processes. Reforming the power engineering and its transition to market relations necessitate one to toughen the requirements for the reliability of the measuring information. Inaccurate measurements are a potential source of misdiagnosis of malfunctions of equipment and they cause incorrect operation of emergency control equipment and erroneous actions of operating personnel in the control of technological processes. Operational methods of reliability control that enhance the operational reliability of the measuring information are based on the usage of the semantic value of the measured data, their consistency, process consistency, and consistency of balance. These methods use technological sense of the measured variables and they complement the methods of hardware status monitoring of automated control systems based on digital codes. That improves the overall operational reliability of the transmission, collection and processing of information. The most common semantic method of control is the method of limits (“fork”) that compares the numeric value of the measured variable with the upper and lower boundaries of valid values. The disadvantage of limit values in many cases is its poor resolution, due to the wide range of appearance of results of measurements. This reduces the probability of detection of gross and systematic errors of measurements more than it may be accepted. With this regard, the objective of a reasonable narrowing of the range of valid values of the variables, that uses the theory of statistical decisions, acquires high relevance.https://energy.bntu.by/jour/article/view/1084power systemmeasurement datavalidation of measurementsfalse alarmomission of gross errorsresolution of control
spellingShingle V. A. Anishchenko
T. V. Pisaruk
THE EFFECTIVENESS OF VALIDATION MEASUREMENTS IN AUTOMATED SYSTEMS OF THE POWER SUPPLY SYSTEMS CONTROL IN ACCORDANCE WITH LIMIT VALUES
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
power system
measurement data
validation of measurements
false alarm
omission of gross errors
resolution of control
title THE EFFECTIVENESS OF VALIDATION MEASUREMENTS IN AUTOMATED SYSTEMS OF THE POWER SUPPLY SYSTEMS CONTROL IN ACCORDANCE WITH LIMIT VALUES
title_full THE EFFECTIVENESS OF VALIDATION MEASUREMENTS IN AUTOMATED SYSTEMS OF THE POWER SUPPLY SYSTEMS CONTROL IN ACCORDANCE WITH LIMIT VALUES
title_fullStr THE EFFECTIVENESS OF VALIDATION MEASUREMENTS IN AUTOMATED SYSTEMS OF THE POWER SUPPLY SYSTEMS CONTROL IN ACCORDANCE WITH LIMIT VALUES
title_full_unstemmed THE EFFECTIVENESS OF VALIDATION MEASUREMENTS IN AUTOMATED SYSTEMS OF THE POWER SUPPLY SYSTEMS CONTROL IN ACCORDANCE WITH LIMIT VALUES
title_short THE EFFECTIVENESS OF VALIDATION MEASUREMENTS IN AUTOMATED SYSTEMS OF THE POWER SUPPLY SYSTEMS CONTROL IN ACCORDANCE WITH LIMIT VALUES
title_sort effectiveness of validation measurements in automated systems of the power supply systems control in accordance with limit values
topic power system
measurement data
validation of measurements
false alarm
omission of gross errors
resolution of control
url https://energy.bntu.by/jour/article/view/1084
work_keys_str_mv AT vaanishchenko theeffectivenessofvalidationmeasurementsinautomatedsystemsofthepowersupplysystemscontrolinaccordancewithlimitvalues
AT tvpisaruk theeffectivenessofvalidationmeasurementsinautomatedsystemsofthepowersupplysystemscontrolinaccordancewithlimitvalues
AT vaanishchenko effectivenessofvalidationmeasurementsinautomatedsystemsofthepowersupplysystemscontrolinaccordancewithlimitvalues
AT tvpisaruk effectivenessofvalidationmeasurementsinautomatedsystemsofthepowersupplysystemscontrolinaccordancewithlimitvalues