Analytical Study of Zinc Sulphide Electrode Prepared from Nano material

Zinc Sulphide nanoparticles (NPs) has been prepared from raw material by microwave method. ZnS NPs were characterized by X-ray Diffraction (XRD) and Scanning Electron Microscopy (SEM), The size of ZnS NPs were about (3.15nm) calculated from the Scherer formula from the most intense XRD peak, The ca...

Full description

Saved in:
Bibliographic Details
Main Authors: Ali I . Khaleel, Khalaf F. Al-Samarrai, Marwan A. mahmood
Format: Article
Language:English
Published: Tikrit University 2023-02-01
Series:Tikrit Journal of Pure Science
Subjects:
Online Access:https://tjpsj.org/index.php/tjps/article/view/1080
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849427378561875968
author Ali I . Khaleel
Khalaf F. Al-Samarrai
Marwan A. mahmood
author_facet Ali I . Khaleel
Khalaf F. Al-Samarrai
Marwan A. mahmood
author_sort Ali I . Khaleel
collection DOAJ
description Zinc Sulphide nanoparticles (NPs) has been prepared from raw material by microwave method. ZnS NPs were characterized by X-ray Diffraction (XRD) and Scanning Electron Microscopy (SEM), The size of ZnS NPs were about (3.15nm) calculated from the Scherer formula from the most intense XRD peak, The calculated product for ZnS was about 94.4%.Zn2+-selective electrode based on poly vinyl chloride (PVC) was prepared by using ZnS Nanoparticles (NPs) powders and di-butyl phthalate, and were compared The analytical specifications of ZnS NPs and ZnS Microparticles (Non- NPs ) electrode. ZnS NPs electrode and ZnS Non- NPs  electrode give linear range upon (10-5-10-2)M and (10-4-10-2)M, Nernstain slope of (30.35 mV/decade) and (30.84 mV/decade), correlation coefficient of (0.9999) and (0.9995), detection limit of (1.733x10-7)M and (2.486x10-6)M, quantitative limit of (5.77x10-7)M and (7.07x10-6)M, the response time of (9-39) second and (13-36) second, respectively. The lifetime for each electrode was 15 days. The optimum conditions for each electrode were (5-7), (20-30 ̊C) and (10-4) M for pH, temperature and concentration of filling solution respectively. The selectivity of electrodes were measured using mixed solutions method, the results showed that the selectivity coefficient values for all interferences ions are less than one.
format Article
id doaj-art-c1eecac924ea4e47ae048948b4507373
institution Kabale University
issn 1813-1662
2415-1726
language English
publishDate 2023-02-01
publisher Tikrit University
record_format Article
series Tikrit Journal of Pure Science
spelling doaj-art-c1eecac924ea4e47ae048948b45073732025-08-20T03:29:03ZengTikrit UniversityTikrit Journal of Pure Science1813-16622415-17262023-02-0121610.25130/tjps.v21i6.1080Analytical Study of Zinc Sulphide Electrode Prepared from Nano materialAli I . KhaleelKhalaf F. Al-SamarraiMarwan A. mahmood Zinc Sulphide nanoparticles (NPs) has been prepared from raw material by microwave method. ZnS NPs were characterized by X-ray Diffraction (XRD) and Scanning Electron Microscopy (SEM), The size of ZnS NPs were about (3.15nm) calculated from the Scherer formula from the most intense XRD peak, The calculated product for ZnS was about 94.4%.Zn2+-selective electrode based on poly vinyl chloride (PVC) was prepared by using ZnS Nanoparticles (NPs) powders and di-butyl phthalate, and were compared The analytical specifications of ZnS NPs and ZnS Microparticles (Non- NPs ) electrode. ZnS NPs electrode and ZnS Non- NPs  electrode give linear range upon (10-5-10-2)M and (10-4-10-2)M, Nernstain slope of (30.35 mV/decade) and (30.84 mV/decade), correlation coefficient of (0.9999) and (0.9995), detection limit of (1.733x10-7)M and (2.486x10-6)M, quantitative limit of (5.77x10-7)M and (7.07x10-6)M, the response time of (9-39) second and (13-36) second, respectively. The lifetime for each electrode was 15 days. The optimum conditions for each electrode were (5-7), (20-30 ̊C) and (10-4) M for pH, temperature and concentration of filling solution respectively. The selectivity of electrodes were measured using mixed solutions method, the results showed that the selectivity coefficient values for all interferences ions are less than one. https://tjpsj.org/index.php/tjps/article/view/1080Zinc Sulphidenano materialanalytical studyZnS NPs electrode
spellingShingle Ali I . Khaleel
Khalaf F. Al-Samarrai
Marwan A. mahmood
Analytical Study of Zinc Sulphide Electrode Prepared from Nano material
Tikrit Journal of Pure Science
Zinc Sulphide
nano material
analytical study
ZnS NPs electrode
title Analytical Study of Zinc Sulphide Electrode Prepared from Nano material
title_full Analytical Study of Zinc Sulphide Electrode Prepared from Nano material
title_fullStr Analytical Study of Zinc Sulphide Electrode Prepared from Nano material
title_full_unstemmed Analytical Study of Zinc Sulphide Electrode Prepared from Nano material
title_short Analytical Study of Zinc Sulphide Electrode Prepared from Nano material
title_sort analytical study of zinc sulphide electrode prepared from nano material
topic Zinc Sulphide
nano material
analytical study
ZnS NPs electrode
url https://tjpsj.org/index.php/tjps/article/view/1080
work_keys_str_mv AT aliikhaleel analyticalstudyofzincsulphideelectrodepreparedfromnanomaterial
AT khalaffalsamarrai analyticalstudyofzincsulphideelectrodepreparedfromnanomaterial
AT marwanamahmood analyticalstudyofzincsulphideelectrodepreparedfromnanomaterial