SELECTING RATED CAPACITY FOR POWER TRANSFORMERS

The article proposes a method for selecting the rated capacity of oil-immersed power transformers adjusted for a more accurate calculation of their load-carrying capability. A more precise method to determine load-carrying capability of oil-immersed power transformers, which is admissible with valid...

Full description

Saved in:
Bibliographic Details
Main Authors: M. I. Fursanov, I. I. Dul
Format: Article
Language:Russian
Published: Belarusian National Technical University 2015-06-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/852
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543735928324096
author M. I. Fursanov
I. I. Dul
author_facet M. I. Fursanov
I. I. Dul
author_sort M. I. Fursanov
collection DOAJ
description The article proposes a method for selecting the rated capacity of oil-immersed power transformers adjusted for a more accurate calculation of their load-carrying capability. A more precise method to determine load-carrying capability of oil-immersed power transformers, which is admissible with valid technological normative documents, is offered and reasoned. The major attention focuses on the analysis of the requirements of the technological normative documents on selecting the rated capacity of oil-immersed power transformers. The authors present the critical analysis of the well-established and extremely simplified method for ratedcapacity selection of power transformers and justify its inconsistence.The paper shows that all the methods for selecting power-transformers rated capacity are the simplifications of the transformers load-capability assessment method based on thermal transient-processes computations. It is reasoned that the requirements of any transformer  operational-mode acceptability can be most precisely expressed in the form of critical-point allowable temperatures and the allowable overload-factors used in most applied methods are only indirectly calculated values. Allowable-temperature critical points regimented by the technological normative documents are cited.   The authors point to possible errors of the simplified selection-methods for rated capacity of oil-immersed transformers and adduce the computation results of the mathematical modeling of the thermal transient-processes under simplified conditions assumption to illustrate the  possible errors. The thermal transient-processes computation results for a transformer with   a 168-hour random electrical-load list demonstrate the performance capabilities of the offered  method.
format Article
id doaj-art-c1a5d9a96c51449985b7e170aca4ea55
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2015-06-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-c1a5d9a96c51449985b7e170aca4ea552025-02-03T11:34:19ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412015-06-01021120834SELECTING RATED CAPACITY FOR POWER TRANSFORMERSM. I. Fursanov0I. I. Dul1Belarusian National Technical UniversityBelarusian National Technical UniversityThe article proposes a method for selecting the rated capacity of oil-immersed power transformers adjusted for a more accurate calculation of their load-carrying capability. A more precise method to determine load-carrying capability of oil-immersed power transformers, which is admissible with valid technological normative documents, is offered and reasoned. The major attention focuses on the analysis of the requirements of the technological normative documents on selecting the rated capacity of oil-immersed power transformers. The authors present the critical analysis of the well-established and extremely simplified method for ratedcapacity selection of power transformers and justify its inconsistence.The paper shows that all the methods for selecting power-transformers rated capacity are the simplifications of the transformers load-capability assessment method based on thermal transient-processes computations. It is reasoned that the requirements of any transformer  operational-mode acceptability can be most precisely expressed in the form of critical-point allowable temperatures and the allowable overload-factors used in most applied methods are only indirectly calculated values. Allowable-temperature critical points regimented by the technological normative documents are cited.   The authors point to possible errors of the simplified selection-methods for rated capacity of oil-immersed transformers and adduce the computation results of the mathematical modeling of the thermal transient-processes under simplified conditions assumption to illustrate the  possible errors. The thermal transient-processes computation results for a transformer with   a 168-hour random electrical-load list demonstrate the performance capabilities of the offered  method.https://energy.bntu.by/jour/article/view/852oil-immersed power transformersload-carrying capabilitythermal transient processesmathematical modeling
spellingShingle M. I. Fursanov
I. I. Dul
SELECTING RATED CAPACITY FOR POWER TRANSFORMERS
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
oil-immersed power transformers
load-carrying capability
thermal transient processes
mathematical modeling
title SELECTING RATED CAPACITY FOR POWER TRANSFORMERS
title_full SELECTING RATED CAPACITY FOR POWER TRANSFORMERS
title_fullStr SELECTING RATED CAPACITY FOR POWER TRANSFORMERS
title_full_unstemmed SELECTING RATED CAPACITY FOR POWER TRANSFORMERS
title_short SELECTING RATED CAPACITY FOR POWER TRANSFORMERS
title_sort selecting rated capacity for power transformers
topic oil-immersed power transformers
load-carrying capability
thermal transient processes
mathematical modeling
url https://energy.bntu.by/jour/article/view/852
work_keys_str_mv AT mifursanov selectingratedcapacityforpowertransformers
AT iidul selectingratedcapacityforpowertransformers