Intelligent operation and maintenance of power communication network based on data perception fusion

Under the common influence of multiple factors and structural complexity in the power communication network, traditional operation and maintenance methods are vulnerable to the disturbance of abnormal voltage signal and abnormal transformer signal in the perception process, resulting in the global p...

Full description

Saved in:
Bibliographic Details
Main Authors: Huahui LYU, Zhe MING, Kai FAN, Qingming CHEN, Hongyu SHI, Wenjing ZOU, Dingbo WANG, Shengtao GUAN, Yong WU
Format: Article
Language:zho
Published: Beijing Xintong Media Co., Ltd 2024-01-01
Series:Dianxin kexue
Subjects:
Online Access:http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2024016/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841533667161145344
author Huahui LYU
Zhe MING
Kai FAN
Qingming CHEN
Hongyu SHI
Wenjing ZOU
Dingbo WANG
Shengtao GUAN
Yong WU
author_facet Huahui LYU
Zhe MING
Kai FAN
Qingming CHEN
Hongyu SHI
Wenjing ZOU
Dingbo WANG
Shengtao GUAN
Yong WU
author_sort Huahui LYU
collection DOAJ
description Under the common influence of multiple factors and structural complexity in the power communication network, traditional operation and maintenance methods are vulnerable to the disturbance of abnormal voltage signal and abnormal transformer signal in the perception process, resulting in the global perception of the network and seriously affecting the overall operation and maintenance effect.In order to effectively solve the problem of perception bias caused by multiple factors, the data perception fusion algorithm was used to optimize the perception of the power parameters under the power communication network, so as to realize the effect of improving the perception accuracy and optimizing the overall quality of operation and maintenance.In the optimization scheme, the situational awareness scope of power communication network security was determined firstly.Secondly, the situational awareness of voltage security under power communication network operation was optimized.Thirdly, the security situational awareness parameters of power network transformer were defined based on the data perception fusion algorithm.Finally, the data perception fusion calculation of perception information was completed.The simulation comparison test shows that the data perception fusion algorithm has the ability to improve the overall quality of operation and maintenance, reduce the perception deviation in the process of operation and maintenance, and improve the perception sensitivity and accuracy.
format Article
id doaj-art-c150cad4aebf4d3689abcf4c5a27c341
institution Kabale University
issn 1000-0801
language zho
publishDate 2024-01-01
publisher Beijing Xintong Media Co., Ltd
record_format Article
series Dianxin kexue
spelling doaj-art-c150cad4aebf4d3689abcf4c5a27c3412025-01-15T02:57:35ZzhoBeijing Xintong Media Co., LtdDianxin kexue1000-08012024-01-014013614359557430Intelligent operation and maintenance of power communication network based on data perception fusionHuahui LYUZhe MINGKai FANQingming CHENHongyu SHIWenjing ZOUDingbo WANGShengtao GUANYong WUUnder the common influence of multiple factors and structural complexity in the power communication network, traditional operation and maintenance methods are vulnerable to the disturbance of abnormal voltage signal and abnormal transformer signal in the perception process, resulting in the global perception of the network and seriously affecting the overall operation and maintenance effect.In order to effectively solve the problem of perception bias caused by multiple factors, the data perception fusion algorithm was used to optimize the perception of the power parameters under the power communication network, so as to realize the effect of improving the perception accuracy and optimizing the overall quality of operation and maintenance.In the optimization scheme, the situational awareness scope of power communication network security was determined firstly.Secondly, the situational awareness of voltage security under power communication network operation was optimized.Thirdly, the security situational awareness parameters of power network transformer were defined based on the data perception fusion algorithm.Finally, the data perception fusion calculation of perception information was completed.The simulation comparison test shows that the data perception fusion algorithm has the ability to improve the overall quality of operation and maintenance, reduce the perception deviation in the process of operation and maintenance, and improve the perception sensitivity and accuracy.http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2024016/data perception fusionpower communicationnetwork intelligenceoperation and maintenance technology
spellingShingle Huahui LYU
Zhe MING
Kai FAN
Qingming CHEN
Hongyu SHI
Wenjing ZOU
Dingbo WANG
Shengtao GUAN
Yong WU
Intelligent operation and maintenance of power communication network based on data perception fusion
Dianxin kexue
data perception fusion
power communication
network intelligence
operation and maintenance technology
title Intelligent operation and maintenance of power communication network based on data perception fusion
title_full Intelligent operation and maintenance of power communication network based on data perception fusion
title_fullStr Intelligent operation and maintenance of power communication network based on data perception fusion
title_full_unstemmed Intelligent operation and maintenance of power communication network based on data perception fusion
title_short Intelligent operation and maintenance of power communication network based on data perception fusion
title_sort intelligent operation and maintenance of power communication network based on data perception fusion
topic data perception fusion
power communication
network intelligence
operation and maintenance technology
url http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2024016/
work_keys_str_mv AT huahuilyu intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion
AT zheming intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion
AT kaifan intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion
AT qingmingchen intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion
AT hongyushi intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion
AT wenjingzou intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion
AT dingbowang intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion
AT shengtaoguan intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion
AT yongwu intelligentoperationandmaintenanceofpowercommunicationnetworkbasedondataperceptionfusion